Laserfiche WebLink
'� I�m�1i l'�tTl r7tR I it I I I I Ih' I I 111 I I l l I'I'I 'AIIR�'1'1'�^�I <br />1/2" DRYWALL <br />DOOR JAMB (REFER 1x4 (—1/2" DRYWALL <br />DOOR JAMB REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO PRODUCT f— <br />TO PRODUCT <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />1 X 4 <br />tlIX4 <br />APPROVAL FOR CONN. / <br />1x4 <br />i 1x4 P.T. <br />3-1/4" LONG X 3/16" 0 FURRING <br />3/16"0 X 3" LONG FURRING <br />i <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16 x 3-1/2 <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCON @ 16" O.C. & 4" 2X8 <br />BLOCK@ SPACING „ <br />1 DETAIL <br />O.C. 2-ROWS INTO 1x8 P.T. <br />FROM EACH END w/ MIN. 1X8 <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /2" DETAIL <br />1 x8 w/ (2) ROWS 8d NALS " <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />„ <br />STAGGERED @ 12 O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER EACH END W/ MIN <br />2" EDGE DIST. <br />TO PRODUCT <br />APPROVAL FOR CONN. i % i <br />2x8 P.T. w/ (2) ROWS 3/16" <br />TO PRODUCT <br />APPROVAL FOR CONN. j <br />(2) ROWS 3/16" x 3-1/2" <br />x 3-1/2" TAPCON @ 16" 1x4 <br />O.C. & 4 FROM EACH <br />TAPCON @ 16" O.C. & <br />L <br />FURRII <br />END w/ MIN. 2" EDGE DIST. <br />4" FROM EACH END w/ 2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" 2x8 <br />2x DETAIL <br />2 1/4" DETAIL <br />STAGGERED@12"0' 3-1/41' DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS <br />SCALE: N.T.S. <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BILK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL — <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45A DIAGONAL (4)10d NAILS INTO <br />7/16" OSB <br />BRACE(S) 2 x 8 BRACE/BLKG. <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />\\_2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />INSTALL WDW. SCREW ANCHOR—( <br />INTO ARCH BLKG. PER <br />INSTALLATION DETAILS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW---�� <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />ir <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO <br />SOLID BLKG. AT TOP BTWN. ARCH FBLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B—g ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />SECTION <br />A -A <br />2'-0" 78- <br />2'-0" <br />1/4" x 31/4" TAPCONS <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />�— 2 x 8 45 DIAAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX. $ <br />FILL SOLID <br />BOTH CELLS <br />#5 REB( <br />(TYP,) <br />STD. 90' <br />F_ HOOK (1 <br />±5A <br />___ __ <br />L\_ NOTCH WEB AT <br />FIRST 2 COURS- <br />;APACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7) 1/4"X2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'Y." WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />i <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />ALL <br />(5)12d NAILS <br />SIMPSON <br />2X6 TO 2X4 <br />H2.5A w/ (10) <br />8d NAILS <br />-- <br />/ <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE NOTE: <br />REMAIN FREE OF MORTAR. <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BY—/ <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />4'-0" MAX SEE PLAN <br />#2 CONT (MATCH T <br />IF TRUSSES USED) W/ (2) #6 X 4%." WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" =1'-0" SS <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />(1) #5 BARS CONT. WHERE THIS CONDITION <br />TOP WITH MIN. 3" OCCURS <br />COVER 6'-0" <br />C. ° <br />� o r <br />GRADE <br />° <br />M <br />Z <br />' (2) #5 REBAR. MIN. 3" <br />16" MIN. 00, COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE <br />INSTALLTION <br />it <br />DO NOT DO THIS ' <br />2"x BOT. PLATE W/ (2)1 Od @ 6" O.C. <br />♦ <br />#5 REBAR (TYP,) ' <br />3/4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />tR <br />♦ <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />O.C., 2 ROWS STAGGERED <br />` <br />2x BAND JOIST W/ FACE NAIL 10d <br />` D. 90° HOOK (TYP.) <br />@ TOP & BTTM CHORD, AND (8) <br />YP.) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />— <br />LV <br />METAL SEAT PLATE <br />NOTE: <br />I LAP SHEATHING TO <br />OF BAND <br />JOIST TYPICAL <br />, <br />'; <br />#*# <br />�*4BOTTOM <br />SIMPSON HGAMIOKTA @ 12" O.C. <br />w/ (4) 1/4xl 1/2" SIDS SCREWS <br />' +2 NOTC Fr@ @ FIRST COURSE <br />` <br />' ♦ <br />- <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />THE <br />:S I ♦ <br />, , <br />FILLED CELL INSTALLATION H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />r— ALUM DRIP EDGE <br />BRG WALL TYPE <br />PER PLAN 2x SUB FASCIA <br />2X2 #2 P.T. MIN, <br />FASTENED PER NOTE <br />2 BELOW I L CONT VENTED OR SOLID SOFFIT <br />CONT 2X4 NAILED TO 2x BLOCKING NAILED TO TOP <br />BLOCKING w/ 2-12d NAILS (**) CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. 2x2 #2 MIN. P.T. w/ J-CHANNEL SECURED @ 24" O.C. FASTEN TO: <br />CMU w/ 3/16"x3" TITEN2 @ 16" O.C. <br />WOOD w/ 0.148"x 3 1/4" @ 16" O.C. <br />3. [F] CHANNEL APPLICATION: 2X2 NOT REQUIRED SEE (PA) INSTALLATION GUIDE <br />SF01 STRUCTURAL SOFFIT <br />SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS 71'-4" <br />REV. 03.26.2021 BLOCKING REQUIRED, FOR SOFFITS < V-4" <br />MID BLOCKING NOT REQUIRED <br />FOR VINYL SOFFITS > V-0" SHALL HAVE MID <br />BLOCKING PER R704.2.1 <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2X0 <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />/TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2X4 SCAB FOR Z-6" TO 4'-0" O.H. <br /><FNGTN (2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />PLYWOOD SHEATHING <br />+ <br />+ <br />BLOCKING AS <br />+ REQUIRED TO <br />+ + <br />+ SUPPORT SOFFIT <br />/ CENTER SOFFIT - <br />PRECAST LINTEL <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION rM <br />SCALE: 3/4" = V-0" SS <br />eFG cuGPT n) ntin <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 3 - -v <br />Cr <br />Z <br />O <br />M <br />w <br />O <br />w <br />U <br />U) <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />t! I <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. • ° '' <br />•a <br />OVERHAN <br />., d <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1 r-0r( 51-011 <br />, #5 BAR <br />•i P `'° • CENTERED W/ g <br />.: ° • . �► IN TOP o <br />• sa ' KNOCKOUT/ N <br />° CHAIR BLOCK <br />MONO FOOTINGI I. ° <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS <br />CLEAN FILL .> ° • ° <br />DIRT Z <br />°• ° STANDARD o <br />90' HOOK N <br />#5 BAR IN <br />FILLED CELL , <br />sk <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />DTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />DNTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />4" SAW CUT <br />A SECTION <br />1 SCALE: N.T.S. <br />SCALE: N.T.S. <br />,4 <br />N <br />r <br />VZ <br />R 0 <br />F E s <br />/� <br />Mill1111111 <br />� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />M <br />a <br />In <br />E <br />o cog gam# <br />U <br />0 <br />dq'S " <br />O °N' *k LL <br />M <br />ii <br />� cN'� <br />Q <br />J LL LL <br />� <br />Z <br />TaZ <br />M; 0 <br />:0;; <br />$ <br />� <br />W <br />W <br />xo <br />�j�rnrn Q a a <br />Z <br />00 a <br />N M U Z X 0 O <br />Q <br />Z <br />W <br />O U ❑❑❑ <br />0 <br />z i <br />Z n <br />r <br />-- <br />z <br />10 <br />v0 <br />a--+ <br />�V <br />w 8 <br />N <br />Ln <br />C N <br />N <br />04 <br />20 <br />W <br />z <br />J <br />U_ <br />0 <br />0g <br />W <br />go <br />oLL <br />I <br />L N <br />aR <br />Z® <br />E o0U <br />(— C <br />K 4 <br />30 <br />U <br />z <br />o E <br />N <br />$<Z <br />ao <br />�o <br />(p <br />N <br />"' � <br />z1. <br />Y <br />h� <br />0 <br />? <br />z <br />N J <br />ch y> <br />�mw <br />o<o iO <br />q 6 <br />i6 <br />Z o <br />J U <br />WT <br />3 <br />c� 3� <br />LL <br />Nw <br />C <br />4 <br />aE <br />_9 <br /><2 <br />¢ O <br />o <br />w� <br />UI4 <br />of <br />U� <br />L� <br />Cfl <br />J <br />O <br />(0cc <br />c� <br />L. <br />N <br />> <br />L <br />0 <br />Q <br />30 <br />C m <br />p <br />T. <br />CD <br />Lo <br />Te <br />r <br />2 oLO <br />r <br />.= <br />0 <br />T— <br />N <br />N <br />co <br />0 <br />Z <br />E C)c <br />m <br />a. <br />v <br />v <br />Q o <br />c <br />JOB <br />NO : <br />21-5703 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />