My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3294 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3294 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:56:58 PM
Creation date
2/19/2025 10:33:32 AM
Metadata
Fields
Template:
Building Plans
Street #
3294
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20902
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br />cam' <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RInrF I INF <br />+ + <br />+- + + + + + + + + <br />+ + + + + + + + + + + -� + + <br />+ <br />+ <br />+ -I- + f + + + 4 <br />+ <br />+ + + + + + + + -+ + + + + + <br />+ + <br />++ <br />+ ++ I_+++++� <br />++++++++++++++ <br />+ <br />+ <br />+ + ... + + + + + <br />+ + + + + + + + + + + + + + <br />+ -F <br />+ + <br />+ <br />+ 4 <br />+ + <br />6'-0" <br />+ <br />+ + <br />6'-0" <br />+ + <br />F+ <br />+ <br />+ + <br />+ + <br />F+++ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />++++ <br />+ <br />+ ++ <br />r <br />+ + + + + + <br />+ <br />+ + + + + ++++++ <br />+ <br />+ + + + '� 4+ <br />Z++ <br />+ <br />+ + + + + ++ + + + <br />+ + + + + + io <br />+ <br />+ + + + + + + + + + + <br />++ <br />+ <br />++++++++ <br />�+ <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />-RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3l4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7� <br />panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5l8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />FILL CELL STD. 90° HOOK BOND BEAM <br />w <br />Ix <br />a <br />> <br />. CONT. #5 <br />STD90° <br />CONT. #5 <br />BAR <br />HOOK BAR <br />W� <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br /><` CONT. BASE PLATE <br />BEARING COLUMN ;.<\ <br />__ <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />'! .: = FOR BLOCKING/TJI <br />i <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />\\ <br />� ��•., TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />/ Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />DOUBLE JOIST CONSTRUCTION SECTION @INT. BRG. WALL <br />(Not required if both loaded equally from above) * N.T.S. <br />r <br />Filler blocking 118" min <br />' ) Small gap 2" min. <br />2" max. 4 max. <br />1/8" gap / Web Stiffener Fastener Schedule <br />Joist Bearina Location _ <br />Series Depth I End Intermediate <br />9-1/2" 2-8d -- 2-8d <br />x / NK 1 BCI 5000s7 11-7/8" 2-8d 33 8d <br />Clinch nails <br />14 <br />I. 9-1{2" <br />2-8d <br />2_ <br />-8d- <br />5-8d <br />2-8d <br />when <br />possible <br />J <br />BCI 6000s® <br />BCI 6500s ®; <br />11-7/8" <br />14' <br />16" <br />2-8d <br />_ 2-8d <br />2-8d <br />3 8d <br />- - <br />5-8d _ <br />6-8d <br />1) Support back of web during nailing to prevent damage to 7 11-7/8" 2-8d 3-8d <br />web -flange connection. __ <br />_ -- BCI 60s 14" . 2-8d..__- 5-8d <br />2) Block solid between joists for full length of span. Tight fit -- - 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-7/8"_ 3-16d_ 3-16d <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener A 2" min. BCI 90s® 14" 1 5-16d_ _ 5-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4" max. 16" 16-16d 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with side nailing. <br />- Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top irdsmouth cuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />"Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />1/16 <br />code for appropriate <br />details in One 10d box <br />areas--20 of high or--20 sinker <br />ii <br />lateral load. nail each side <br />10'-0" <br />at bearing. <br />i <br />T <br />TANK -LESS W/H <br />/"- <br />6 <br />;2� CORNER OF <br />HOME <br />GARAGE SIDE <br />x <br />!' <br />a <br />a <br />H C G <br />000 <br />5'-0" <br />STUB -OUT FOR <br />GAS METER 0 o Un <br />1 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS" <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'4" <br />1 SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-l" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />81-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />"1. Provide adequate bearing <br />for each lapped joist. <br />Old nails SECTION @INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />g <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer _ Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or I <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below." <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel "Non -stacking walls <br />require additional consideration. <br />• <br />, <br />• <br />6., A 1 2° ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />8 <br />V-0" <br />V-1" <br />1'-2" <br />V-2" <br />1'-3" <br />V-3" <br />1'-7" <br />1'-11" <br />2'-4" <br />2'-9- <br />3'-2" <br />3'-7" <br />—__ Any_ 16" joist ---- - 12 <br />V-0" <br />1'-1" <br />1'-2" <br />V-2" <br />1'-3" <br />1'-9" <br />2'-4" <br />2'-11" <br />Y-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />Span`(ft) - 16 <br />V-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-7" <br />2'-0" <br />3'-2" <br />3'-10" <br />4'-0" <br />5'-7" <br />6'4" <br />7'-2" <br />- 20 <br />V-0" <br />V-1" <br />1-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />W-11" <br />7'-11" <br />8'-11" <br />-- -.---- __-_ — - - 24 <br />V-0" <br />V-1 " <br />1'-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10" <br />7'-2" <br />8'-4" <br />9'-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE *2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9, THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. <br />GIRDER TRUSS <br />2X TOP PLATE <br />5/8" fI <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />II=11;:1IN <br />Backer block (12" wide min.)—,Tj111J—I [—LI T—f1 <br />Nail with 10-10d nails. — — <br />` Install tight to top flange. • ' :. <br />SLEEVE THRU STEM <br />SEE PLAN FOR <br />• •.•'.: <br />Joist hangera. • <br />FOUNDATION INFO • a' <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />- I 1/4"-2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />I <br />i� 0.6 X Joist <br />°oo <br />oo/ depth <br />lo <br />_ IjI <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />a <br />i— REINF. SEE PLAN <br />/--A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />JOA <br />LOCATION OF <br />SECOND H10A <br />SIMPSON (WHEN <br />w/ (18)10d REQUIRED) <br />NAILS <br />UPLIFT=1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE\ <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE PLUMBING LINE <br />PENETRATION <br />e a ..d L <br />a a •' o 'a : a <br />Z \n ' • < • <br />ko � w <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />AV. °/ av G <br />d . <br />a a <br />4 t4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />00.� <br />zm <br />z <br />a <br />E3 <br />Z <br />to U <br />0 <br />a) C., <br />w <br />M <br />•O <br />w <br />Lh Of <br />V U <br />M <br />o <br />w <br />a1 M <br />C-)MU_C, <br />¢ rn <br />in S v <br />ai Q d <br />N_ <br />V N <br />00 <br />U) <br />LL <br />LuLU I <br />Ch <br />zd <br />Z pLL j3 <br />Z CA J6f <br />W !!!CA� o <br />°` U, r! <br />`l✓ S N <br />J <br />S 0 . <br />'r'• .r�••••''...• •'O� <br />//'ar <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering potions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />ru <br />za <br />g� U <br />U4Z <br />s;3 <br />N <br />°C <br />n <br />ILL] <br />H <br />z <br />g <br />� <br />z <br />O <br />c <br />V <br />a <br />19S <br />0 <br />J <br />bjo� <br />1� <br />z <br />J <br />In <br />r_4 <br />� <br />a <br />Z <br />ti <br />u <br />M <br />� <br />m <br />r-I <br />p <br />z <br />Z <br />_ <br />S <br />0 <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION N0. 4nO <br />SHEET NO. <br />SN 1 <br />