Laserfiche WebLink
F <br />00 <br />r <br />I! <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SO. <br />SO. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />1 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />'*NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: Y4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by save or comics vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />IJ q�- <br />U <br />� <br />z <br />z® <br />Q <br />c <br />13 <br />V) (D <br />(a) <br />C <br />i- J W <br />r) <br />�U <br />— <br />OLU <br />�M , <br />'v U <br />M <br />� <br />W <br />M <br />U <br />LL <br />Q <br />Qr) <br />� � o <br />e D. <br />�JJ� <br />N 10 <br />v � N <br />Nz z <br />U)3 <br />�LU <br />Lu <br />30 N o <br />0yItP! <br />LL _ Q <br />W <br />Nab o <br />W W W iSNG.0 <br />(b . <br />• fir, ' <br />J <br />--i t� <br />?0FE.S5X0��\�\ <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications oontained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Editlon. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and see]. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />L <br />is <br />�z000 <br />U <br />Wz <br />uJ <br />O <br />Ili C4 <br />r� <br />/L <br />W <br />Z <br />Q <br />z <br />Q <br />= <br />w <br />U <br />v <br />I? <br />Q <br />J <br />LL <br />P <br />T <br />O}�+ <br />cr- <br />w> <br />QSIE <br />W <br />� <br />Ll1 <br />di <br />z <br />t4V8 <br />u <br />FL <br />Ln <br />� <br />OQ <br />O <br />r <br />Z <br />z <br />5 <br />�j <br />LU <br />= <br />8 <br />a <br />f <br />r <br />.-+ <br />a <br />to <br />s <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION NO° 4w0 <br />SHEET NO. <br />5.0 <br />