Laserfiche WebLink
3 <br />i� <br />a> <br />v <br />v <br />S <br />L0 <br />C" <br />0 <br />0 <br />I <br />s <br />m <br />v <br />v <br />x <br />L0 <br />0, <br />0 <br />0 <br />ao <br />-o <br />i <br />3 <br />a <br />02 <br />N <br />0 <br />o. <br />Q <br />0 <br />x <br />0 <br />J <br />N <br />r7 <br />0 <br />U <br />v <br />O <br />UI <br />U <br />O <br />a <br />00 <br />N <br />00 <br />1X4 1/2" DRYWALL <br />i <br />\ <br />1/2" DRYWALL DOOR JAMB REFER <br />DOOR JAMB (REFER 1 X 4 r ( <br />1 X 4 1/2" DRYWALL <br />, UNACCEPTABLE INSTALLTION <br />, <br />DOOR JAMB REFER <br />( P.T. <br />TO SHT. SDW2-K1 <br />TO SHT. SDW2-K1 L TO SHT. SDW2-K1 <br />PROPER INSTALLATION MAX. <br />8 <br />DO NOT DO THIS <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS FOR CONN. DETAILS <br />1 X 4 <br />1 X 4 <br />` ' <br />#5 REBAR (TYP,) <br />3/4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ Sd 4" <br />1 X 4 <br />3-1/4" LONG X 3/16"0 FURRING <br />„ „ <br />3/16 X 3 LONG FURRING 3/16"0 X 3-1/2" LONG <br />FURRING <br />#5 REBAR ` <br />' <br />AND NAILED W/ 8d COMMON @ <br />6 O.C. EDGES AND 12" O.C. FIELD <br />@ <br />O.C., 2 ROWS STAGGERED <br />TAPCON. INTO <br />TAPCONS TAPCONS STAGGERED <br />STAGGERED @ 16" <br />2X8 <br />(TYP,) <br />BLOCK@ SPACING " <br />1 DETAIL <br />1X8 P.T. STAGGERED @ 16" O.C. <br />O.C. 2-ROWS INTO 2-ROWS INTO <br />1X8 <br />JOIST <br />2x BAND JOIST W/ FACE NAIL 10d <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1/2" DETAIL MASONRY THROUGH <br />3 <br />�� <br />DETAIL <br />STD. <br />STD. 90^ ` /� <br />90° HOOK (TYP.) <br />@TOP & TTM CHORD, AND (1 <br />1x4 P.T. & 1x8 P.T. 1x8 P.T. & 2x8 P.T. <br />FILL SOLID <br />BOTH CELLS <br />HOOK (TYP.) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />3/16" x 3 -1/2" <br />METAL SEAT PLATE <br />TAPCON @ 16" <br />O.C. & 4' FROM <br />1X4 P.T. <br />3/16 x 3 -1/2 DOOR JAMB (REFER <br />1 X 4 1/2 DRYWALL <br />NOTE: <br />LAP SHEATHING TO <br />DOOR JAMB (REFER EACH END W/ MIN <br />DOOR JAMB (REFER TAPCON TO SHT. SDW2-K1 FOR <br />BAND <br />BOTTOM D <br />TO SHT. SDW2-K1 2" EDGE DIST. <br />TO SHT. SDW2-K1 CONN. DETAIL <br />PI <br />JOIST TYPICAL <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />10d @ 12" O.C. <br />1 X 4 <br />J <br />FURRING <br />— � <br />2X8 P.T. WITH 3/16"0 X 3" <br />' +2� <br />NOTC @ FIRST COURSE <br />SIMPSON HGAM1OKTA @ 12" O.C. <br />EWS <br />LONG S <br />2x P.T. AS REQ'D <br />2X8 P.T. <br />STAGGERED @ 16" O.C. <br />EKED <br />2X8 <br />INTO BAND JOIST & (4)1R/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />2x DETAIL <br />2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1/4" DETAIL <br />±5^ <br />NOTCH WEB AT THE <br />FIRST 2 COURSES <br />` <br />BUILDOUT OVER SIZE DOOR <br />-WINDOW ROUGH OPENINGS CC <br />FILLED CELL <br />FOUNDATIONPER PLAN <br />FILLED CELL INSTALLATION <br />H <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. <br />INFO SCALE: N.T.S. <br />SCALE: N.T.S. <br />SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />SECTION <br />UPLIFT CAPACITY = 805 # FOR 1 STRAP <br />W/ 1/4" x 31/4" TAPCON ( 1 1/4" MIN. <br />A -A <br />= 1610 # FOR 2 STRAPS <br />FILL 1st4 COURSES <br />EMBEDMENT INTO BLK.) 1/4" MAX <br />SOLID W/GROUT <br />8" <br />1 PLY PRE-ENGINEERED TRUSS <br />1 X 4 FURRING SOLID BLKG. AT TOP BTWN. <br />1/4" x 31/4" TAPCONS <br />BLOCK HEADER ARCH BLKG. & BUCK <br />SIMPSON HM9KTw/ (4)1/4"xl 1/2" SDS <br />1/2" DRYWALL * <br />SCREWS & (5) 1/4" x 21/4"TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />8d NAILS AT 8" O.C. AT BUCK <br />SINKERS AND (7)1/4"X21/4" TITEN = 2150 #) <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />INSIDE TO ALLOW FOR INSULATION <br />° <br />7/16" OSB <br />TO BE INSTALLED <br />BOND BEAM OR CAST IN PLACE BEAM <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />POLY -CELL IN THIS AREA <br />2 x 8 45 DrAGONAL BRACE AT EA. <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER wsTRucTIONs. ; <br />SCRIBE (NOTCH) <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />RETROFIT TRUSS DETAIL <br />OVERRAN . �. <br />° <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />N.T.S. <br />INSTALL WDW. SCREW ANCHOR-2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4 PROVIDE TAPCON WITHIN <br />INTO ARCH BLKG. PER ) 10d NAILS THRU OSB INTO 2 x 8 <br />RETROFIT WALL OVERHANG DETAIL NTS <br />4" MIN. OF BRACE <br />INSTALLATION DETAILS A <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />-A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR <br />THRU <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF <br />ARCH <br />START OF ARC <br />IF TRUSSES USED W/ 3 #6 X 4'%" WOOD <br />) () / <br />SCREWS 16" O.C. MAX. OR IF MASONRY WALL <br />* DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />/ <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />@ / <br />(2)1Od NAILS @ 8" O.C. <br />ARCH DETAIL <br />4' MAX. RAD. <br />USE (1) SIMPSON 1/2 HD TITEN (CENTERED) w/ / <br />XOV <br />FR/y TO TRUSS TOP CHORD <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />+ <br />� <br />(F G7• <br />1,-fir, 5,_Orr <br />SCALE: N.T.S. <br />SS <br />12 <br />+ + y PLYWOOD SHEATHING <br />JACK TRUSS PROVIDED BY SEE <br />+ + <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />+ + <br />+ <br />INISH FLO <br />QR <br />2 <br />x 8 BUCK - CONNECT TO BLOCK <br />SECTION <br />+ + BLOCKING AS <br />• <br />° <br />`� <br />WITH <br />1/4" x 31/4" TAPCON (1 1/4" MIN. <br />B-B <br />ROOF SHEATHING ATTACHED <br />+ REQUIRED <br />„ EMBEDMENT INTO K.) <br />/4 MAX <br />PER NAILING SCHEDULE ALL <br />TO SUPPORT <br />+ <br />e.. ° D: #5 BAR <br />--:CENTERED <br />Z-0" 8" <br />TRUSS SOFFIT <br />+ + <br />b . D• I. o <br />D ° W/ <br />BLOCK HEADER <br />SOLID BLKG. AT TOP BTWN. ARCH <br />(5)12d NAILS SIMPSON <br />+ <br />p• e <br />9 H IN TOP <br />1 X 4 FURRING <br />BLKG. &BUCK <br />2X6 TO 2X4 H2.5A W/ (10) <br />8d NAILS <br />2X4 SYP . ®s <br />EACH TRUSS <br />. D e o <br />D .' ' KNOCKOUT / N <br />° CHAIR BLOCK <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 8 DIAG. BRACE BT <br />2 x 8 VERT. W/ (2) 1 Od <br />NAILS AT EA. END <br />PROVIDE (2) MIN. <br />PROVIDE 2x <br />CONT. W/ <br />CONNECTOR '® <br />_ I <br />MONO FOOTING ' ,a e. • • D e <br />x <br />(3) <br />SIZE AND REINF. PER PN <br />LA <br />VERT. BRACES WHEN HGT. OF <br />TAPCON AT EA. SIDE <br />12d NAILS <br />SEE LINTEL <br />AND SECTION DETAILS -I <br />BRACE EXCEEDS 24" <br />BUCK - (1) WITHIN 4" <br />JACK TRUSS PROVIDED BY <br />SCHED. <br />• <br />LEAVE A CUT OUT IN O.S.B. ON T <br />MIN. OF START OF <br />TRUSS COMPANY OR 2X4 <br />CLEAN FILL D ° • e D <br />2 x 8 VERT. BRACE(S) <br />INSIDE TO ALLOW FOR INSULATION <br />ARCH <br />#2 SYP @ 24" O.C. <br />bENTER SO IT <br />DIRT 6 z <br />TO BE INSTALLED <br />011 <br />BUILT UP PLWD. BUCK - <br />4'-0" MAX SEE PLAN <br />PRECAST LINTEL <br />e ° STANDARD o <br />SCRIBE (NOTCH) BACKSIDE <br />7/16" OSB ARCH PANEL <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />SEE ELEVATION <br />> 90' HOOK N <br />#5 BAR IN <br />TO FIT ARCH CONNECT W/ <br />IF TRUSSES USED) W/ (2) #6 X 4'/2" WOOD <br />FOR OVER HANG <br />FILLED CELL e , ' e� . ' s� . . ' • <br />8d NAILS <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />START OF ARC <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />(MAX. 4'-0") <br />. . L ., . ., <br />INSTALL WDW, SCREW <br />BTWN. OSB ARCH FACES W/ (4)1 Od NAILS <br />EQUAL EQUAL <br />4' MAX. RAD. <br />WALL USE (2)1/4" X 3112" TAPCONS AT 16" <br />_, <br />•° <br />s• , , ,' s• , , ,' s• , •, <br />IN,• ,Sk <br />', s• <br />ANCHOR INTO ARCH BLKG. <br />THRU OSB INTO 2 x 8 <br />O.C. <br />PER INSTALLATION DETAILS <br />B-BMONO <br />ARCH DETAIL rK <br />SECTION a@ ENTRY L <br />SECTION@ ROOF EXTENSION M <br />STEMWALL FOOTING SIZE AND <br />REINF. PERLAN AND STEMWALL <br />TO STEMWALL FOOTING <br />SCALE: N.T.S. SS <br />SCALE: 3/4" = 1'-0" SS <br />SCALE: 3/4" =1'-0" SS <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />GLASS BLOCK INSTALLATION NOTES <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />EXISTING BOND BEAM. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />SEE SHEET D2 AND <br />EPDXY CAP TO PREVENT LEAKAGE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />FLOOR PLAN FOR <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />MORE INFO <br />TOP SPACE BETWEEN EXISTING GROUT &NEW GROUT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT, FOR SOLID GLASS <br />ANCHOR <br />x 1 <br />SIMPSON2" <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2" ) <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />"SQUEEZED" <br />W.W.M. AT PERIMETER <br />1/2" NAILS STUDS & - <br />NILHTT4 U S & (1) <br />COURSES TO PREVENT THE MORTAR FROM BEING OUT. <br />1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />(1) #5 BARS CONT. <br />L <br />5/8" DIA. ALL THREAD ROD <br />O <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />TOP WITH MIN. 3" OCCURS <br />EPDXIED w/ SIMPSON "SET" <br />z <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />COVER 6'-0" <br />EPDXY MIN. 6" EMBEDMENT & <br />0 <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />( EVERY OTHER <br />F•F• <br />3 MIN. EDGE DISTANCE <br />FILL CELL FULL HEIGHT W/ <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LL v <br />NON SHRINK GROUT. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />e <br />O <br />A <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />; v D <br />w a <br />REINFORCING AS FOLLOWS: <br />I —I I I If I i <br />1 <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />—��— <br />o e I II�II� <br />g <br />#5x6' EMBEDDED INTO <br />* PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE <br />D .D ( <br />z <br />EXISTING FOOTING (2) #5x6' IN CONC. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />_ <br />.: <br />N <br />FILLED CELL <br />SMOOTH. DO NO FURROW. <br />D ° <br />r <br />` <br />DRILL 3/4 x5 MIN. HOLE <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />GRADE D, D - <br />SET BAR IN EPDXY <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH, <br />6 MIN. LAP <br />p <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />"' z <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION <br />NOTES. <br />�2 o <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />e ° <br />'0 <br />4" SAW CUT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />\ D (2) #5 REBAR. MIN. 3" <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />. <br />16"MIN. COVER EAWAY <br />SECTION <br />BLOCK SHALL BE INSTALLED PER <br />A <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />EXISTING FOOTING <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />1 SCALE: N.T.S. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />RETROFIT FOR MISSING MSTAM STRAP <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />RETROFIT <br />FILLED CELL DETAIL <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />SCALE: 3/4 - -1-0 <br />_ , „ <br />SCALE: 3/4' - 1-0 <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />SCALE: N.T.S. <br />INSTALLATION OF GLASS BLOCK. <br />(D <br />:2!: <br />CD <br />Z mEj <br />z <br />V) C9 <br />�,u <br />w <br />•p <br />W <br />o <br />U <br />o0 <br />m <br />W <br />O <br />N M <br />0,C,) <br />_ Qj <br />O O N <br />t" o <br />U <br />o <br />no <br />Q rn <br />N <br />Ln oo v <br />rn Q d <br />All <br />B D® <br />I ° <br />B,D C 1W <br />N `D <br />YI 00 O M W <br />�"6z <br />Z W w z <br />~ <br />U_ w <br />W -N*!.� a w <br />._ o <br />W t,i ¢Ej ckzo-S-0,4!; <br />1 r w <br />e OW <br />'' <br />i"`'��' E `.Q <br />l�r�a�flFESS�p <br />1!k%N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L NAR <br />4600 W. Cypress St, Suite 200 I Tampa, FL 33607 <br />www.Lennaffampaxom <br />0z <br />0 <br />Lo <br />LU <br />za <br />zg0 <br />z U z Q <br />Z <br />0 u� <br />0 <br />�ap� <br />W <br />/"\ <br />0 L0 <br />z <br />L <br />^ <br />L.L. <br />z <br />�o <br />2: <br />> <br />z <br />CZL <br />V) 3: <br />rl <br />z <br />O <br />"a <br />JW <br />U <br />T <br />V, <br />J <br />o o <br />R 0 <br />�- <br />nc <br />I— <br />U, <br />LLJ <br />0_ <br />z <br />N <br />Z <br />Zarb <br />o 0 <br />w <br />J <br />r-i <br />CW <br />G <br />Q <br />Z o <br />wwO <br />Ln <br />rN. <br />Q <br />Z <br />Z <br />Paz <br />m <br />ZJ <br />yz <br />V) <br />O <br />oo <br />g <br />= <br />rn <br />,-i <br />CL <br />cn <br />in <br />SCALE : AS NOTED <br />DATE : 11 /28/2018 <br />TECH: MJAMES <br />VERSION N0. 4sO <br />SHEET NO. <br />SS <br />