My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3306 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3306 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:40:05 PM
Creation date
2/19/2025 10:33:47 AM
Metadata
Fields
Template:
Building Plans
Street #
3306
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20752
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
cc <br />m <br />r <br />it <br />x <br />to <br />M <br />0 <br />0 <br />J <br />n <br />n <br />1 <br />12 <br />00 <br />0 <br />x <br />ELECTRICAL SPECIFICATION <br />200AINDEL <br />CENNTERTER <br />NOTES: <br />00 #14 copper to lights & outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />MUST VERIFY WITH THE <br />10 #1copper to WH <br />SPECIFICATIONS FOR THE TYPE <br />#70.2 -3 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MAIN O <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />j NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />(3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />3 <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />i <br />TT 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />.o <br />O <br />THERMOSTAT <br />� <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />00 <br />w <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />GE) <br />(1) PHONE LINE, (1) DATA PORT <br />WID H.B. <br />GFI DISC. <br />L JL--U Ild'1I GL.J RCI.iCr I <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />M1 III Mr-D <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />I <br />'0 <br />Z CD <br />0 <br />— o <br />Z <br />a <br />Z <br />W � <br />+-� W <br />Mo <br />V — <br />W <br />O <br />— <br />DU <br />�- <br />o <br />�� <br />2� <br />m <br />W <br />o <br />—U�11 <br />N <br />N M <br />l3) ch <br />O O N <br />LL 00 <br />U <br />00 <br />0 Y fz <br />o <br />Q rn <br />to 0 <br />c Qv <br />rn Q o <br />B D® <br />a DC <br />N�C� <br />-*I <br />N `D <br />O 10 <br />M O � <br />N O O N O <br />Z W 8 <br />I.. g� . a <br />o w <br />�. ULLo ua <br />N W W <br />� <br />W — (L'mLLtu <br />a <br />Z 0 0 CDQ � o <br />HSf <br />LL 4 IR `° W Q Cl) Q <br />A <br />O v C) O <br />WWW.FDSENG.COM 17-1 <br />V <br />0 <br />N <br />00 <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 <br />Z <br />�o <br />�o <br />fg <br />Zw <br />oW�o <br />J <br />�� <br />xowZ <br />J <br />���_j <br />aapw <br />O��o <br />��Lo <br />QU <br />W <br />Zo <br />2: <br />L.L� <br />F_ <br />Z z <br />LL <br />a <br />W <br />J <br />W <br />� <br />O <br />O <br />J <br />�g <br />U <br />= <br />J <br />000 <br />Ie <br /><.RP <br />F <br />. <br />LL <br />aR 6 <br />O m. a <br />w<¢ <br />¢<,0,0 <br />oo�o <br />Z <br />LU <br />J <br />L / <br />T-I <br />W <br />2:d <br />Q <br />to H � O <br />g�0 <br />WZ <br />Ln <br />*k <br />z <br />m <br />06 <br />Z <br />g <br />= <br />o� <br />J <br />¢ uj <br />rn <br />T-I <br />a <br />to <br />s <br />SCALE : AS NOTED <br />DATE : 11 /28/2018 <br />TECH: MJAM ES <br />VERSION N0. 4n0 <br />SHEET NO. <br />4.0 <br />I Idh' I I -tat(I -11- <br />
The URL can be used to link to this page
Your browser does not support the video tag.