m <br />tR <br />00 <br />Iu <br />0 <br />v <br />[Z <br />N <br />f � <br />NM <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA1 <br />200 AMP <br />MAIN <br />O <br />200 amp <br />150 amp <br />#14 copperto lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 410 SER Alu <br />POWER CO. FEEDS j <br />INTERSYSTEM �,IlJll <br />4 Bare Cu Ground <br />BONDING <br />#i4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />------------------------------------------------ <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42 centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />411�3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />�R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />—� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />} q <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_Mai <br />DISCONNECT SWITCH <br />12 <br />l� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />Rt III nFR <br />MAIN FLOOR ELECTRICAL PLAN_ <br />SRI <br />Z r> <br />0 <br />_ m <br />Z <br />Z Q <br />Q <br />L/) 0 <br />�w <br />�o <br />OLU <br />C <br />C) <br />�� <br />�f— <br />U <br />o0 <br />m <br />F= U <br />pp <br />N <br />N M <br />;O <br />O o 0 <br />swCC) <br />C <br />o <br />Q0) <br />U) o. o <br />Lr)8.:S <br />"% Q d <br />B U. <br />N -C <br />;r <br />N N <br />.w V N <br />y ♦O M 01 00 <br />Z W $M�z �' z <br />+ <br />� r <br />W p <br />"- <br />W Z w <br />W VQ�LL� 3 a <br />'0,w <br />Z EC <br />LLA R O 1� <br />mN <br />Q <br />v <br />W <br />O U U Ot— <br />WWW.FDSENG.COM <br />00 <br />0 <br />N <br />00 <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />L E N AR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 <br />rr � <br />f� <br />Z <br />Wa�0 <br />zoo <br />zW�X <br />0 w <br />Q <br />to <br />UC3co <br />wt0 <br />s``_ <br />(� <br />10-1nG <br />z o <br />U <br />/ <br />U <br />£ <br />g <br />LU <br />Z <br />� <br />Q <br />J <br />3 <br />I=- <br />� <br />N <br />L U <br />o <br />V <br />Z <br />w <br />O <br />` <br />O <br />= <br />O <br />E <br />. <br />o0 0 <br />a 0 <br />I- <br />.,..w. <br />LI_. <br />z <br />6 <br />WOma <br />N <br />Lr) <br />Q <br />oo� <br />N <br />Q<w <br />~ow�� <br />Z <br />o6-R <br />LU aZ 10� <br />W <br />J <br />Li <br />�-{ <br />� <br />Z <br />tLmLU �o�Lli <br />$r< <br /><Q <br />Z <br />�ZS <br />m <br />O <br />Zo <br />Uj <br />= <br />1 i <br />Qf <br />rn <br />,-11 <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 11 /2/2018 <br />TECH: KFRAZER <br />VERSION NO. 5ol <br />SHEET NO. <br />4.0 <br />