My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3315 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3315 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:11:42 PM
Creation date
2/19/2025 10:34:13 AM
Metadata
Fields
Template:
Building Plans
Street #
3315
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
2351
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O <br />O <br />21' <br />S3 <br />37'-8" <br />35-S H <br />16-3" <br />\ I <br />a_ <br />0- <br />\\ <br />OJ <br />O <br />J <br />\ <br />\ <br />N <br />r <br />W = <br />U o <br />TW <br />U <br />\ \ <br />30'-0" Noo <br />iO <br />N <br />CAFE <br />4-0\\ <br />FAMILY ROOM V ULT.0 G <br />\ <br />VAULT. CLG. <br />\\I� <br />CARPET <br />aim <br />PATIO co <br />co <br />O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />E <br />w I <br />0 I <br />0 <br />LO <br />I <br />2:12 SLOPE <br />CEILINI <br />I I <br />I � <br />I <br />9'-0" T-8" 2'-8" 4'-3" 6'-10" T-7" <br />I <br />5'-0" 1 -5s G DR ER VENT <br />O S3 TH RU ROOF <br />h <br />I <br />S #2 SYP <br />STUD <br />S SS G <br />= HTT4@ BASE S3 <br />N I <br />OWNER'S <br />SUITE <br />8 -0 FLAT CLG. <br />CARPET <br />TYP @ 1 STORY <br />I <br />a A <br />T S3 <br />9. <br />0 <br />= w <br />O LO <br />N uJ <br />I <br />00 L - - - - - - - - - - J <br />00 <br />N 0I I <br />1_ ---- D.W. o o <br />3L _ 24 - J 18 •1 <br />-1 -- 9',2 ,INK w� DISR <br />2' 61' ,-2„ 1 8 <br />i <br />rMEN ..: N <br />o_ <br />=w <br />�w <br />0 <br />rn- <br />� : 1 <br />�! 1 <br />CARPET <br />a4 <br />30'-10" <br />TILE <br />4068 B.F. <br />T-83" <br />4 <br />ILM <br />FIBERGLASS <br />SURROUND <br />HALE <br />9'-4" FLAT CLG. <br />CARPET <br />I <br />ENTRY <br />I <br />8'-0" FLAT CLG. <br />I <br />I <br />HANSON BOX @ <br />36" A.F.F. M <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />K 2-CAR GARAGE <br />S3 8'-0" FLAT CLG. <br />�I <br />I / K \ <br />---. - - W W c? c�D 4-SH ro ' <br />11'-4" N N 2'-4" cG°\t <br />1 � <br />CLG. I Li <br />I <br />---t-TS q U)I m <br />-600 <br />BEDROOM 2� �`; 'BEDROOM <br />O 8'-0" FLAT CLG. I 8'-0" FLAT CLG. <br />CARPET I CARPET <br />T' I EGRESS I EGRESS <br />25-SH 25-SH <br />S3A O O <br />A <br />(V <br />C? <br />I <br />I <br />W (3) #5'S E.W. <br />I <br />I I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I I <br />I 17 <br />I � <br />I <br />I <br />I <br />I I <br />I <br />L----------- <br />R&S G.T. <br />40681 B.F. <br />9'-8"' I <br />EDROO 4 <br />8'-0" FLAT CL <br />CARPET I <br />I <br />2'-6" x 2'-6" x 1'-0" <br />W/ (3) #5'S E.W. <br />10 <br />W r. <br />10 <br />A <br />S3 <br />�U) <br />O <br />r <br />Wrn <br />Cl) <br />o� <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />H2 <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 114" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX257' <br />S.H. <br />13 <br />20X38J <br />18-1X37 <br />S.H. <br />14 <br />20X50J <br />18-IX 50 <br />S.H. <br />15 <br />20X63 <br />18JX62J <br />S.H. <br />16 <br />20 X 72 <br />181 X 71 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />11-13 <br />271/4X38J <br />26x37 <br />S.H. <br />1 H4 <br />27 a X 50 1 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 a X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 d X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 a X 50 1 <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 � X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 7' X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 1 WIDE <br />S.H. <br />32 <br />54 X 26 <br />5271 X 251 <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S. H. <br />35 <br />54 X 63 <br />52 J X 62 1 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 z <br />S. H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 112" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />DA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />OG <br />SEE SIN SHEET OH SEE SIN SHEET <br />1 L�Q MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />GARAGE 427 <br />FRONT ENTRY 32 <br />TOTAL AREA 2276 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />FLOOR PLAN - ELEV-Al CONDITIONED CEILING RBLOWN-IN <br />N <br />(INSTALLLL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />SCALE. �Qrr=1 r-Orr (GARAGE / LIVING) <br />i <br />11N'14 <br />``, "ftil1111110\\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida <br />Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />CD <br />W <br />a <br />o OT E <br />o ° <br />� <br />O N N �°° J <br />N 01 LL <br />5 <br />0 <br />0 J <br />�, m , <br />7W N Yk LL W <br />NJ <br />y <br />cnr--P� LL w a <br />p j M V , a Y <br />�i <br />U W w a- u <br />Z <br />_ o <br />@ V O <br />> <br />y°o O ~ w <br />'@ (V CO O J <br />m <br />Q Q a <br />Z <br />LL <br />co 0 a <br />Un Cl) z of O <br />N Q U U)i <br />Z <br />O <br />W <br />❑�❑ <br />z � M <br />o g <br />(0 <br />N <br />Q o Q <br />� <br />rz � <br />N <br />M <br />z <br />W y <br />O <br />�N <br />,, o <br />Ly N <br />Cn <br />U <br />W <br />all= <br />J <br />U <br />ml° . <br />L <br />alb•.• <br />U o <br />0 <br />0 <br />-c <br />� m <br />r- <br />o <br />co <br />� <br />w <br />M <br />M <br />w z <br />p <br />z <br />Q <br />.J <br />QE <br />o <br />�o <br />QF, <br />z© <br />o� <br />H <br />Cl <br />R <br />¢ ¢ <br />D U <br />U <br />U � <br />o <br />o 3 <br />4) <br />a0 <br />wo <br />¢❑ <br />az <br />�z <br />i <br />ro <br />co <br />- a <br />� <br />om r <br />m� <br />I , <br />°, <br />U:) J <br />az <br />2 . <br />3 <br />oCn <br />0� <br />S� <br />!? <br />LL <br />a <br />m w <br />U <br />< <br />3 <br />x <br />Q� <br />o <br />o <br />CD <br />�< <br />�o <br />a� <br />O0 <br />V <br />zk <br />0 <br />Q <br />NN <br />, <br />�,j, <br />N= <br />M: <br />0 <br />ui <br />L <br />j(N <br />C <br />U <br />co <br />C <br />o <br />.� <br />o <br />o <br />I� <br />c <br />Tom[ <br />v <br />04 <br />T- <br />.� <br />-0 (0 <br />LO <br />o <br />w N <br />a <br />E <br />CIO <br />z <br />Z <br />E <br />c <br />FLU <br />E <br />J <br />Q <br />J <br />JOB <br />NO: <br />19-0251 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />i I ., I It a1I11 Ti-51.-tll� iTiTTiil-i1 Ai W�,u i,�llduttt .iE: Frraiu nl�u.uu ieL!_.. iGi1� � i„� i- �i.,,� , <br />
The URL can be used to link to this page
Your browser does not support the video tag.