Laserfiche WebLink
"F-Pi <br />-------------- <br />12 <br />5� <br />1 0" <br />01 <br />T-0" TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />12 <br />5� <br />F4 <br />F5 <br />12 <br />�5 <br />1"x10" SMOOTH <br />TEXTURED BAND <br />m� <br />FRONT ELEVATION - Al <br />16-0" RIDGE VENT <br />3'-0 RIDGE VENT <br />TEXTURED FINISH <br />12 <br />�5 <br />T.O.P. <br />T.O.M. <br />_ HDR HGT <br />— — — — _ _ _ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />NOW <br />_1'-8" _ <br />25 SH 25 SH <br />F. F L. <br />................................................................. ] <br />LEFT ELEVATION - Al <br />W, <br />N <br />O <br />o <br />r <br />oo 00 <br />CD <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />\ .� <br />Z6 <br />' <br />CD <br />r <br />i <br />•. <br />FL O <br />� <br />�O,' IE 10�* <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />W <br />a <br />� <br />vE (� <br />o o00 <br />M °r <br />N <br />v <br />Cl N & J <br />6 LL <br />C: <br />G <br />�LO� LL w <br />a <br />H <br />Q <br />a w <br />LL <br />':_JV IL W <br />J LL LL a- Lu <br />0 <br />Z <br />— rn 0 <br />0Pw <br />W <br />rc°4 <br />-� @ N co LL 0 � <br />I IL Z <br />Urn°. d a <br />L Za <br />� O <br />a <br />N <br />N <br />o� ��Cn <br />W <br />N M <br />0 0 <br />z10 <br />Z N <br />o Q <br />a N <br />V) <br />M <br />4 <br />.0 <br />LU <br />o <br />0/a <br />w o <br />ai <br />CJ � <br />W J <br />— � 8 <br />�'•.. <br />zl�. <br />L Qj <br />U O N <br />Q <br />O <br />N <br />I� <br />o <br />o <br />� <br />w <br />co <br />coo3 <br />a <br />z <br />a <br />� <br />J <br />LL. <br />Q E <br />0 <br />w <br />oa <br />c <br />O E <br />o <br />R0 <br />�< <br />0O <br />o< <br />az <br />L <br /><o <br />wo <br />Q <br />ww <br />�� <br />ro <br />rp <br />Y <br />o <br />0, <br />Q 2i <br />F <br />o� <br />zz <br />ao <br />U�- <br />w <br />o <br />O <br />CID <br />= <br />r <br />O <br />2 O <br />> Lo <br />0 <br />o rn <br />m <br />0 <br />^L <br />W <br />•' <br />0 <br />Q <br />O <br />C m <br />o <br />r <br />O r <br />= Np <br />N N <br />T <br />0 <br />E <br />N <br />E p <br />.. <br />o <br />Z <br />M <br />z <br />� <br />E Q <br />�; <br />N <br />f° <br />a <br />E o <br />U _ <br />.0 m <br />Q p <br />act <br />_J <br />JOB <br />NO: <br />19-0251 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />- I I I f i. l i t it-1 --I — <br />