My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3315 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3315 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:11:42 PM
Creation date
2/19/2025 10:34:13 AM
Metadata
Fields
Template:
Building Plans
Street #
3315
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
2351
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13, Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to lights 1, outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND DisconnL#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM Bare Cu Ground <br />BONDING WIRE <br />TERMINATION PER WITH CODE APPROVI <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />PATIO <br />GFI <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />\ <br />\ Tf <br />7T <br />\ <br />\ <br />\ <br />in CAFE <br />FAMILY ROOM <br />\ <br />\ <br />` 1 <br />10 <br />\ --------------------------- <br />ROUGH -IN FbR <br />OPT. CLG. FbN/ LIGHT \ <br />\ PRE -WIRE <br />� I <br />I � <br />I C.M <br />I � <br />I <br />I F_ -- —+— <br />k / \ <br />OW� R'S I <br />WITE <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />W.I.C. ):� _--\,,� <br />-7--_— — — <br />EC <br />DW <br />.C. SWITCH <br />PENDANT AS <br />PER SPECS <br />1 <br />0 DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE G <br />HOOD PER SPECS <br />I / I <br />-i- <br />B 1 H <br />ROUGH -IN FOR <br />OPT. CLG. VN/ <br />—� LIGHT PREIWIR ; <br />I I <br />BEDROOM 2 <br />S.D <br />i1 <br />I <br />ENTRY <br />I <br />WP I <br />GFI <br />Y) IR�GATION <br />GFI 44" A.F.F. <br />AHU W H n 11 W/ (3) #5'S E.W. <br />l; <br />I1 /I I <br />T � I <br />OPT. effT.I <br />D. W. �''-------�-� I <br />I GARAG E <br />GARAGE DOOR <br />\ LIGHT AS I GFI <br />PER SPECIt <br />0 VP <br />� I GFI -A.F.F. 21RQ/R-A E I <br />W <br />®� d <br />� L5 J I <br />LX 1 1 1 0 U I <br />/ i J <br />I/ " F <br />LU <br />J L— <br />> w— — — — — — — — — — — <br />GFI @ 44" <br />lip /K A.F.F. <br />H <br />(C.M) 'li' <br />1 \ <br />EDROOM 4 <br />3 <br />ROUGH -IN FOR G , ROUGH -IN FOR <br />PT.CLG FAN/ <br />LLIIGHT PRE WIREBED�OOM 3 \ OPT. CLG. FAN/ <br />3 E.W.la <br />L�i�i TxP�,tl�/I�rr <br />/ \ / (3) #5'S <br />' \ __ -- <br />VERIFY METER LOCATION <br />WITH BUILDER <br />EM <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60"A.F.F. <br />O <br />THERMOSTAT <br />M 11 <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />—� <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />ELECTRICAL <br />PLAN <br />- <br />ELEV-Al <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L r J <br />OPT. CEILING FAN <br />SCALE: %4"=1'-0" <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />0 <br />N <br />co <br />v <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida <br />Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />a <br />'oco <br />�E 00 <br />o ,0 op F_ xt <br />N <br />O N <br />u- <br />LL <br />�t <br />V <br />C <br />N O C <br />L-�mo <br />J <br />u `a <br />vi <br />QN <br />�r--r� <br />LL W <br />d `L <br />_j <br />�LL� <br />a u <br />0 <br />Z <br />0o <br />0 <br />�o� <br />c a <br />ILW��°jO1 <br />Z <br />¢ a <br />_j <br />Nco <br />M Z <br />U <br />O <br />LO U_j W <br />z <br />O <br />WCD <br />❑oo <br />z � M <br />o CD <br />z W � <br />� o � <br />Vn ! <br />rzrpM1y 'gyp <br />' <br />W <br />V O <br />— u- <br />4-1 <br />C <br />0 W o <br />N C <br />o <br />U <br />w m <br />•... <br />— J E <br />O <br />.. <br />S r Q <br />V O N <br />in, U) <br />401 <br />N Ol <br />14 <br />o <br />cZ <br />w <br />M <br />J <br />O <br />C <br />Co E <br />CD-O <br />U <br />a <br />Z <br />of <br />0o <br />H <br />x0 <br />o E <br />oa <br />�o <br />S< <br />az <br />cliO <br />F,_ <br />¢ O <br />¢� <br />J <br />m� <br />_� <br />0r <br />z <br />Zm <br />U:)�° <br />J <br />N <br />m <br /><w <br />rn <br />2)o¢ <br />Q� <br />ZZ <br />go <br />,� <br /><0 <br />a <br />w <br />_ <br />o <br />o <br />w¢ <br />Xo <br />a= <br />E2 <br />(U > <br />Q <br />0 <br />L <br />> <br />N <br />L_ <br />O <br />n <br />li <br />9 <br />0 <br />m <br />30 <br />= <br />r- <br />O <br />N <br />(0 <br />Ln <br />r <br />� � <br />r <br />E <br />w N <br />0 <br />E <br />z <br />m <br />z <br />E O <br />E <br />N <br />a. <br />U 0 <br />Q p <br />J <br />JOB <br />NO: <br />19-0251 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />