Laserfiche WebLink
24'O/C MAX, <br />OWN 0 04�Ei <br />HURRICANE ANCHOR PER UPLIFT <br />SCHEDULE <br />b' DIA4 STD. STEEL PITS <br />FILLED SOLID W/ CONCRETE <br />DBL. S.P.F. TOP PLATE <br />EMBEDED PIPE PROTECTED <br />W/ CATALYZED POLYURETHANE <br />WALL SHEATHING, SEE TYPICAL <br />CONC. SLAB, SEE PLAN <br />2-STORY WALL SECTION DETAIL <br />2x S,PF. STUDS a 16' O.C. <br />2 ROWS, 5/6'xl0' 'J' BOLT W/ 8' <br />EMBEDMENT STAGGERED 9 24' <br />\ \ 1 <br />O.C., W/ 2' DIA x' WASHER <br />CONC. FOOTING, SEE PLAN <br />6 MIL VAPOR BARRIER <br />USP MSTAM24 (OR EQUAL) W/ (9)10d <br />2'x8' P.T. PLATE <br />COMP. SOIL, SEE PLAN �/ <br />1 <br />INTO STUD 4 (5) I/4 x2-114, TAF'CONS <br />f-WEEP SCREED INSTALLED PER <br />INTO cM<l <br />MANIF. <br />PIPE 5OLLARID <br />DETAIL <br />U5P MSTAM36 (OR EQUAL) W/ (13)10d <br />8'x8'xlb' Ko. BLOCK W/ (1) 05 CONT. 4 FILL <br />SCALE: <br />I/2' <br />INTO STUD 4 l8) I/4'x2-1/4' TAP'CONS <br />SOLID WITH GROUT <br />=1'-0' <br />INTO CMU BOTH 51DES OF WALL i EA <br />STUD (CENTER STRAP a TO.M.) <br />MASONRY WALL (DESIGN AS <br />CANTILEVER) <br />1/2' CDX PLYWOOD OR lnb' O.S.B. SHEATHING- <br />REQV. FOR ALL EXTERIOR OR SHEAR WALLS <br />AS INDICATED ON THE PLAN. ATTACH <br />SHEATHING W/ Sd COMMON NAILS a 4' O.C. e <br />BOUNDARIES, b' O.C. a EDGES, AND a 12' O.C, <br />FIELD <br />5/Vx 10' 'J' BOLT 6 24' <br />O.C. W/ 2*3/16' PLATE <br />WASHER (TYP) <br />2' <br />3 1/2" MIN. <br />z 3 1/2"(min.) - 4" <br />(2) 05 CONT <br />(1) ROW 2x BLOCKING a MID HGT. <br />FOR WALL HGT. S 6-b'. (2) ROW5 <br />2x BLOCKING 0 3rd PTS FOR WALL <br />HGT, > 81-b'. <br />SEE SHT 53 FOR <br />INSULATION CHART <br />2x STUD 6 EA. FLOOR TRUSS <br />(24' O.C. MAX) <br />USP SPT22 CONNECTOR <br />2x P.T. BOTTOM PLATE <br />6xb WIA x WIA <br />WWF OR FIBERMESH <br />�D P A <br />4 <br />(:D <br />WALL 5 CTION 0 POWER <br />SEET YP. 2-5TORY WALL SECTION FOR SCALE: 3/4'=1'-0' <br />ADDITIONAL INFORMATION. <br />i°d'x(o' LAG <br />USP M5TC40 SCREWS AT. <br />ABOVE 6' O,C. <br />STAGGERED <br />// 31/2'(min.1- 4' <br />USP MSTC40 <br />USP 14TTI6 ABOVE <br />U.N.O. MIN. <br />5YM50LS <br />BUILDING SECTION KEY <br />(Section No. over Sheet No.) <br />INTERIOR ELEVATION KEY <br />(Elev. No, over Sheet No.) <br />DETAIL KEY <br />�- (Detail No. over Sheet No) <br />0 WINDOW SCHEDULE KEY <br />(SEE WINDOW SCHEDULE BHT. ) <br />(- STRUCTURAL NOTE <br />O -H HOSE BIBS <br />H.B. <br />AREA TABULATION <br />MODEL 2985 <br />15T FLOOR LIVING <br />1355 SF. <br />2ND FLOOR LIVING <br />1644 SR <br />TOTAL LIVING <br />2999 SF. <br />GARAGE <br />649 SR <br />COVERED ENTRY - ELEY. 'A' <br />45 S.F. <br />COVERED ENTRY - ELEY. 'B' <br />39 SF. <br />TOTAL AREA: ELEV. 'A' 3693 SF. ELEV. 'B' 3661 S.F. <br />* * * * * * <br />A.N. STAND DIMENSIONS <br />GAS = 6' H. x 36' W. x 52' L. <br />ELEC.: = 24' H. x 30 W. x 52' L. <br />****** <br />NOTE TO TRUSS COMPANY: <br />ALIGN TRUSSES TO <br />ALLOW FOR A.H. To <br />BE ALIGNED. <br />* * * * <br />>�a CONNCION DI <br />SCALE: N.T.S <br />* * * * <br />NOTE: <br />ALL INTERIOR ANGLE <br />WALLS ARE AT 45 DEG. <br />* * * * <br />WINDOW SCHEDULE <br />FIRST FLOOR WINDOWS <br />MARK <br />TYPE <br />ROUGH OPENING <br />HEAD HEIGHT <br />CLEAR OPENING <br />CLEAR OPENING 5F. <br />SILL HEIGHT <br />A <br />355H <br />54' X 63' <br />1'-0' <br />48312' WIDE X 2625' HIGH <br />881 S.F. <br />1'-10' <br />B <br />235H <br />38, X 3V <br />1'-0' <br />33312' WIDE X 15.15' HIGH <br />3b4 S.F. <br />3'-10' <br />C <br />25SH <br />38' X 63' <br />1'-0' <br />33312' WIDE X 15,15' NIGH <br />52a SF. <br />SECOND FLOOR WINDOWS <br />MARK <br />TYPE <br />ROUGH OPENING <br />HEAD HEIGHT <br />CLEAR OPENING <br />CLEAR OPENING 5F. <br />SILL HEIGHT <br />D <br />2554 <br />38' X 63' (FRAME) <br />1'-2' <br />33312' WIDE X 2625' NIGH <br />5,89 S.F. <br />T-1' <br />E <br />1/2 336H <br />21' X 39' (FRAME) <br />11-2' <br />23312' WIDE X 15,15' HIGH <br />255 BE <br />31-1111 <br />I <br />A/C PAD <br />50'-0' <br />-0° 5' 4' 9' 6' V-4' -11 10'-3' <br />---- <br />- - -- -10 ---- ---- -------------- ----- <br />- <br />A/C PAD <br />(SPAN OVER <br />+242 / <br />/ <br />26.4 P'SF 14OMPH <br />2 OPENINGS) <br />i <br />140MPN <br />MPH <br />__ <br />H.B./`; F,21,T61-21,1 P5F 140MPH+26,1 <br />0 -� / -298PSF 145 <br />MPH <br />+242 / -2E4P <br />+23,4 / -25b P5F <br />8.4 P5F 145 MPH® <br />+26.1 / -28145 <br />+252 / -215 P5F <br />;:�MPH <br />\ 6068 5L.G1,D ,, <br />, : - - - - -O.H.C. - = c_=: <br />1-01Is6..'; 01 <br />s4 <br />II <br />DWG <br />REF.- - <br />SINK �- - <br />\` <br />19'-0" <br />8' <br />I I11 <br />\ <br />HEN�`- <br />kT <br />N <br />FL CLG, <br />\ <br />X <br />'NOOK\ <br />34' HICSH 10CE WALL,BELOWt <br />I <br />FAMILY ROOM( <br />: \ \ <br />\ <br />ia�r,TE: E ' . L'- <br />R xtE1151oN I- _ - <br />\ <br />I8'-4' x I6'-6' dI <br />V-V FLAT GLG. <br />'':, 12t1' x I6'-6' . ` <br />;r \ 8'-8"F(cAt CLCx. <br />\ __- ---� \ <br />I o <br />\ \ \� <br />\ \ <br />\ - \ .r 26f�8\ <br />S6 <br />ol <br />X <br />�. <br />` <br />Im'_ I0' <br />C : - <br />TO' COLD <br />p <br />GG (W/ STUDS a g <br />1/2 WALL OR SPINDLES <br />1' TO COLUMN <br />L <br />s3 <br />S3 EA TRUSS) <br />PER CUSTOMER SPECS. <br />\ <br />5 . <br />4 - 2- - -` 1 - _-6' <br />D <br />5 SHELVE <br />l5) <br />s3 <br />m aD r S LLl 'aF �51ER,5 <br />UP 1653 <br />Lu,uzoE' <br />8 <br />S6 FRM. SHEAR WALL 2 <br />2 <br />� <br />M <br />-- - --- <br />`° <br />10' T. 4 /-1 b' Iz <br />- - <br />(SIM. W/OUT METAL <br />A <br />0 <br />�o o <br />INSULATED <br />WALL <br />I <br />UPLIFT 4 (2) STUDS Ca THRESHOLD <br />S3 <br />3 T <br />a EA. SET OF TRIM) PROVIDE FATHER PIPE BOLLARD (W/ <br />3 <br />STRIPPING AROUND OPTION GAS W.H. ONLY) <br />r <br />5T01 AGE �s6 e <br />PERIMETER OF DOOR SEE DET. A/2 <br />�, <br />UNDER----- <br />STAIRS <br />8' HEAD HG'T. <br />' <br />53 <br />(SIM, W/OUT <br />3 C,4RA1R,4C� NOTE: W.H. SHALL BE ELEVATED <br />MIN. 18- ABOVE GARAGE FF. W/ <br />301-0' 20'-6' <br />UPLIFT <br />x <br />OPTION GAS W.H, ONLY <br />8'-B' FLAT CLG. ----- <br />TB <br />2 <br />5' 10� 3' 4' 4' I I': 5' 5' <br />\ <br />EA�T�6D <br />_ <br />19'-10' ID -I0.__ <br />------ --- __ _-- - - -- ---� ---_ -� <br />r <br />2066 <br />8-, LAT � <br />G. <br />- <br />22' x 36' ATTIC <br />_ <br />e <br />-'� <br />_ �;; <br />r� <br />4 STEP ry <br />�- - -- - -� ACCESS ABY. W/ <br />1 <br />N <br />:P <br />22 X39 R.O. <br />W.C. <br />LG. , <br />` <br />\� <br />LINE OF GARAGE DOOR <br />LINE OF GARAGE DOOR <br />HB <br />SHVS. /` 1 <br />' <br />IN OPEN POSITION <br />IN OPEN POSITION <br />��� <br />�53 <br />I I � <br />12 -8 6, <br />- <br />I I I <br />20 -2 Ba 10 10 <br />---- - -- - -'--------------- ------ <br />tI1 <br />FLEX <br />K <br />K Is, K <br />�' <br />1 1 <br />12 -0 x 12 -0 <br />V-V FLAT CLG. <br />, <br />84 <br />ib'-0' x 1'-0' <br />54 _ 6K 54 <br />H. GARAGE DR V-0' x 1'-0' O.H. GARAGE DR <br />S6 <br />S3 <br />-- - - <br />- - I <br />+223 / -253 PSF 14OMPH <br />+242 / -21.1 PSF 145 MPHI <br />A <br />- - - <br />LINE OF 2ND � - - - -- - - �8 3 <br />- <br />- - <br />S3 (51Ma <br />53 <br />FLOOR ABOVE <br />+21.4 / -138 P5F 140MPH <br />LINE OF CANTILEVERED <br />_ <br />-26b PSF <br />140MPH +248 / -21� PSF 14OMPH -28b PSF <br />140MPH <br />145 MPH <br />+23,1 / -25b P5F 146 MPH <br />2ND FLOOR ABOVE <br />(ELEVATION '139 ONLY <br />+24.8 / -32.1 <br />+26.1 / -35.1 <br />145 MPH +26,1 / -29,0 PSF 145 MPH <br />PORCH <br />64, CL'G. <br />HGT. <br />_ <br />----- <br />- <br />,4 <br />©) <br />I <br />S3 <br />(SPAN OVER <br />I <br />2 OPENINGS) <br />3'-10, <br />3'-5' <br />T-0' <br />4'-V <br />2'-O' <br />-0' <br />I6'-0' <br />21-81 <br />8-0' <br />1'-81 <br />124' <br />8'-8' <br />-- -- -- - -------- -- <br />4' <br />-- _2' - .-_�_--- --------- <br />50'-0' __- -_.- --- - ...------------- - - -- <br />(DLOWER FLOOR f=)LAN <br />- SCALE: I/4'=1'-0' <br />( K <br />+24.5 / -26b PSF I 14OMPH '' F CLG I 94 <br />+263 / -28b P'SF 1145 MPH 1, 77, <br />LINE OF 2ND 5TORY <br />s PORCH <br />n IL, <br />10 8'-8'CLG, HGT. <br />FLAT SOFFIT g -- <br />-16' 50. CMU <br />COLN, BASE <br />-- 5EE DET. 9/45 FOR <br />I'-4' 3'4 I'-4' I'-4° <br />COLUMN DETAIL <br />13'-4' TO END WALL 1'-4't,29'-4'TO GARAGE WALL <br />MARTIAL LOWER FLOOR PLAN = ELEV. 11E311 <br />SCALE: 1/4'=1'-O' <br />DIMENSION CONVENTION <br />& EXTERIOR OPENING DIMENSION <br />-OUTSIDE FACE OF 8" <br />NOMINAL BLOCK <br />4" FRAME: WALL_ U.N.O. <br />LEGrENO <br />VERTICAL REINFORCMENT IN C.M.U. SHEAR WALL W/ (I -NO.5 BAR IN <br />GROUTED CELL TYPICAL UNO.t HOOK INTO TIE BEAM AT TOP 4 <br />FOOTING At BOTTOM) <br />FILL CELL t0 ONE COURSE ABY PIPE (NO REBAR) <br />CMU SHEAR WALL (BLOCKS BETWEEN FILLED CELLS ARE NOt <br />TO BE FILLED UNLESS SHOWN ON THE PLAN) <br />8'-8' TOP OF MASONRY <br />BEARING WALL 2X STUDS * 16' O.C. W/ 1/2' GYP. (UN.O.ON PLAN) <br />2X STUD W/ i/2' GYP, <br />FLOOR PLAN NOTES <br />I. SEE PRODUCT APPROVAL SHEETS FOR DOOR AND WINDOW TABLES AND <br />INSTALLATION INFORMATION. <br />2. ALL PLUMBING, ELECTRICAL, AND MECHANICAL ROUGH-IN5 MUST BE COMPLETE, <br />INSPECTED, AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION (PER <br />F13C 1103). <br />3, *-DENOTES EGRESS WINDOW <br />4, GARAGE DOOR SHALL BE LABELED WITH A PERMANENT LABEL PROVIDED BY THE <br />MANUFACTURER <br />5. EXTERIOR WINDOWS AND DOORS SHALL BE LABELED WITH A PERMANENT LABEL, <br />MARKING, OR ETCHING PROVIDING TRACEABILITY TO THE MANUFACTURER AND <br />PRODUCT. <br />b. LISTED WIND PISSURES AT EACH OPENING ARE ALLOWABLE STRESS DESIGN <br />PRESSURES, FOR ULTIMATE DESIGN PRESSURES SHALL BE PERMITTED TO BE <br />DIVIDED BY 06. <br />1. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH <br />SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES IN THICKNESS, SOLID OR <br />HONEYCOMB -CORE STEEL DOORS NOT LE55 THAT 13/6 INCHES THICK, OR <br />20-MINUTE FIRE -RATED DOORS. <br />8. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A <br />MINIMUM NO, 26 GAGE SHEET STEEL,1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 <br />OR CLASS I DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE <br />OPENINGS INTO THE GARAGE. <br />16T FLOOR sTRLZTu;Q,4L NOTES <br />lO PROVIDE (1) 0 5 CONT IN 8" PG LINTEL 4 (1) 0 5 IN 8" KO BLOCK ABOVE <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Flodda 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineering.com <br />CA 25948 <br />o <br />0 <br />N <br />Z W <br />O� <br />0 <br />z <br />d �LL <br />LLj <br />z <br />�aaM <br />00 <br />< <br />z uj <br />Lu <br />J <br />O <br />mi <br />o <br />�o <br />L�LJ <br />m <br />uj <br />L <br />=0 <br />W <br />Q <br />0:�0 <br />_ <br />Lu <br />n <br />' <br />w <br />Lu <br />Z <br />< <br />0 <br />U04w <br />00 <br />00 <br />LO <br />LLJ <br />U <br />IO <br />"11::;: <br />() <br />O7 <br />3 <br />FILLED SOLID WITH GROUT. <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />O <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />NOT USED <br />BUILDING CODE, SECTION R301 FOR <br />O3 <br />PROVIDE (1) 0 5 CONT. IN S" P.C. LINTEL W/ 2" RECE55 4 (1)0 5 IN 8" KO, BLOCK <br />140 MPH (Vasil=108MPH), 3 SEC. GUST, <br />EXPOSURE ENCLOSED (INTERNAL <br />�/�`� / <br />ABOVE, FILLED SOLID WITH GROUT <br />PRESSURE COEFFICIENT =t0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />4 <br />(2) 2x12 5P"2 HEADER W/ 1/2' PLYWOOD FLITCH 4 (1) U5P LSTAIS 0 EA. END. <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWNGONLY. <br />PROVIDE (1) JACK 9 EA. END OF HEADER W/ (U USP HTTI6 a BASE LINO ON THE <br />PLAN. (REFER TO DETAILS N/54 4 Q154 FOR ADDL. INFO) <br />© 2018 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />� ,,I <br />(3) 2X4 BUILT-UP COLUMN <br />02 18-TH ESE DRAWO HE <br />OINT PROPERTY FINGS DANSCO EANDDNGIN ERNGARETLLC AND <br />THE CLIENT ON THIS PROJFCr. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />O <br />(1) JACK UNDER HEADER AND (3) STUDS W/ (1) USP Httib BASE <br />REVISION: <br />�i <br />(5) 2X4 BUILT-UP COLUMN W/ USP HTTI6 9 BASE <br />DATE <br />DESCRIPTION - <br />12.13.17 <br />1.00 6TH 17) FBC <br />OS <br />(2) 2x6 BUILT-UP COLUMN W/ USP HTTI6 6 BASE <br />TESD. <br />UPDATES <br />_ <br />12.29.17 <br />_ _ <br />1.01 PLAN REVISIONS TO HVAC <br />SPACE & ELECTRICAL <br />04.30.18 <br />1.02 REV. FLOOR TURSS LAYOUT <br />O (3) 2x6 BUILT-UP COLUMN W/ USP HTTI6 a BASE -- <br />O9 4X4 P.T. COLUMN ON CMU COLUMN BASE W/ (2) USP TDL5 OR PAU44 a BASE, -- <br />1 <br />PROYIDE MIN, b EMBEDMENT INTO SIMPSON = I -Al- EPDXY OR EQUIP. FOR <br />VERSION NO. 1.02 / 04.30.18 <br />ANCHOR BOLTS <br />:Do (2) (2) 2X8 SFK BEAM W/ USP 14TW20 is COLUMN 4 USP THD28-2 MASONRY HANGER <br />At WALL END, USING (6) 3/16' X 13/4' POWERS FASTENERS. EXTEND BEAM PAST <br />' <br />k' <br />x ✓ `ag3 <br />COLUMN TO SUPPORT GABLE TRUSS, <br />C4 .�. r <br />✓ff <br />11 (2) 2X8 SPM BEAM W/ USP THD28-2 HANGER 0 END 4 USP THD28-2 <br />' <br />n . <br />BEAM <br />MASONRY HANGER 0 WALL END, USING (b) 3/Ib' X 13/4' POWERS FASTENERS. <br />: <br />• ' r I <br />L1-I <br />NOTES: <br />` ' �n� <br />M`. <br />1, POWER BOX LINTEL (18 GAUGE) CAN BE USED IN LIEU OF FNECAST LINTEL FOR EQUAL DEPTH 4 <br />, <. a <br />a T d <br />REINFORCEMENT INFO AS INDICATED ABOVE (REFER To POWER B0X LINTEL CATALOG FOR <br />�' <br />a 8 �4 <br />MORE INFO) <br />F "A <br />2. PROVIDE Mil 8' EMBEDMENT FOR HTTI6 ANCHOR BOLTS. ANCHOR BOLTS TO BE ALL <br />THREADED ROD INTO 51MPSON SET-XP EPDXY, SIMPSON TITEN HD, OR J-BOLT. <br />ISSUANCE OF PLANS FROM THIS DESIGNERS OFFICE SHALL NOT RELIEVE THE <br />BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND <br />ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY <br />CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TOLu <br />Q <br />APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE <br />H <br />DESIGNERS OFFICE FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION. <br />a <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT <br />W <br />ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO <br />Z <br />ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER <br />THAN THE DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />W <br />C C <br />c� <br />a� <br />Lu <br />m <br />7- <br />Lll c5y <br />aI <br />to _DN <br />CV <br />W� S-0 <br />QLu ua <br />• R312.13 OPENING LIMITATIONS. REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM SHEET TITLE: <br />THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE LOWER FLOOR PLAN <br />OF A SPHERE 4 INCHES (102 mm) IN DIAMETER <br />EXCEPTIONS: GENERAL NOTES &INFO <br />1, THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF A STAIR, FORMED BY THE SHEET INFORMATION: <br />RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE JOB NO.: 381319 <br />OF A SPHERE b INCHES (153 mm) IN DIAMETER <br />2. GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENINGS WHICH DATE ISSUED: 10.09.18 <br />ALLOW PASSAGE OF A SPHERE 4 3/8 INCHES (Ili mm) IN DIAMETER <br />• HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE DRAWN BY: JH <br />FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT REVIEWED BY: TH <br />DIRECTLY ABOVE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE <br />RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS AS PER <br />FRC 6TH EDITION (2011) R311.1.82 , <br />• ALL OTHERS PARTS OF STAIR SHOULD BE IN CONFORMANCE WITH FRC 6TH EDITION 2 <br />(2011) R311.1. <br />S <br />00 <br />d' <br />LO <br />