Laserfiche WebLink
NOTE: <br />FLASHING SHALL BE INSTALLED AT WALL AND RO <br />INTER5ECTION5, AT GUTTERS, AT ALL CHANGES iN rj <br />SLOPE OR DIRECTION, AND AROUND ROOF OPENI <br />ROOF FLAN <br />SCALE: 3/1(o'=1'-0' <br />EGRE55 NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO <br />ACCE55 TO EXTERIOR THROUGH A DOOR THE <br />WINDOW MUST HAVE A MAXIMUM SILL HEIGHT OF <br />44' MEASURED FROM THE FIN15HED FLOOR OF <br />THAT PARTICULAR ROOM TO THE BOTTOM OF <br />THE CLEAR OPENING. <br />STUCCO FIN15H <br />4' SCORED RAKE <br />3'-11/8' <br />11'-2 3/4' <br />SEE SHEET 1 FOR V MATERIAL INFO <br />12 <br />5t- - <br />`- F26 '\ <br />F31 <br />".v <br />T <br />F. FLOOR ELEV.10'-0 3/4' IIJ <br />lk T. BLOCK ELEV. 6-V <br />ROOF SHINGLES PER SPECS <br />STUCCO FIN15H <br />O ROOF VENT 5CNEIDULE O <br />Verify with General Contractor all roof vent locations, <br />quantities, and sizes. Roof vents shall be installed <br />for a minimum of vented area as listed below or <br />equivalent system per II SEDITION (2011)1-RC, RSOII <br />Mark <br />Location <br />Roof vents or <br />equal system (sq. in.) <br />Soffit Vent <br />(sq. in.) <br />RV 1 <br />2nd Level <br />Roof <br />412 <br />412 <br />RV 2 <br />1st Level <br />Front Roof <br />2l <br />2i <br />RV 3 <br />1st Level <br />Csara a Roof <br />56 <br />56 <br />SEE <br />12 <br />PLAN SEE PLAN FOR <br />9 -2 NEEL H 1CT. TRUSSES <br />8' - 8" B1RC�- 1-IC T. F. FLOOR ELEV. V-0' <br />Or <br />Q <br />2x FRAMING AS REQ. <br />2x4 (TYR) m <br />SEE PLANS FOR BEAM SIZE <br />l2) 2X4 FRAMING <br />STUCCO FIN15H OYER <br />MTL. LATHE 41/16' 055 <br />SHEATHING 4 FRAMING <br />AS REQUIRED <r TRUSSES PER PLANS <br />5EE PLANS FOR POST SIZE <br />P05T TO CMU CONNECTOR 5E AN <br />REFER TO PLANS <br />Uzi <br />2x4 SILL FRAMING 1/2 WALL OR RAILING <br />Ix4 (TYP) <br />2x6 (TYP.) <br />STUCCO FINISH 2x8 WALL STAIR <br />MASONRY WALL <br />SEE FOUN IDATION PLN5 <br />FOR FOOTER SIZE '' <br />-4 <br />SCALE: I/2'=I'-0' <br />RIDGE VENT 12 <br />SHINGLE ROOF PER SPECS, 5 <br />12 <br />12 OFF -RIDGE VENT �5 <br />5� <br />I F1 <br />C5)_JREA� IL 1l ATION II II <br />SCALE: 1/8-0' <br />F31 <br />- 12_' 6CORED BAND-- - <br />SEE DET: 9/45.FOR COLUMN <br />STUCCO FINISH <br />Na F5 <br />ISSUANCE OF PLANS FROM THIS DESIGNERS OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE <br />BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE FOR CORRECTION BEFOG <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE <br />DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />FEE <br />I <br />I <br />FfRONT ELEVATION 11511 <br />SCALE: 1/4' = i' -(0' <br />STUCCO FINISH <br />I0'-0 3/4' <br />EXP. JT. LINE <br />LIGHT TEXTURE SEE 9/45 FOR <br />DECO, FINISH COLUMN DETAIL e <br />0I <br />FLOOR ELEV.i0v-0v <br />SHINGLE ROOF <br />PER SPECS <br />12 <br />�5 <br />F28. - F5 <br />F23 <br />r F23 <br />RIDGE VENT 12 <br />12 <br />A- SHINGLE ROOF PER SPECS. 5 I / <br />12 <br />5 OFF RIDGE VENT ' <br />F23 <br />STUCCO FINISH <br />- SHINGLE ROOF <br />PER SPECS <br />F. FLOOR ELEV.10'-0 3/4' , <br />SCALE: I/8'=1'-0' <br />of <br />—12� <br />\15 <br />EA <br />T <br />STUCCO FINISH <br />EXP. JT. LINE <br />LIGHT TEXTURE <br />DECO. FINISH <br />a <br />5� 5 12 -1 51212 12 5 RIDGE VENT <br />ROOF TRU5SE5 <br />PER PLANS ,\ 5HINGLE ROOF PER 5PEC5. <br />- � T. PLATE ELEV.16-11/5' <br />11\5A H To - <br />C TRU55E5 PER PLAN <br />r- STUCCO FINISH <br />_ 12._. <br />L.......... 15 1 <br />n.-_--.-_-.-- -- - - - - F. FLOOR ELEV. 10 0 3/4 <br />T. BLOCK ELEV. 8'-V <br />- MASONRY WALL t- ----- - - - - - <br />FLOOR 5Y5TEM _ EXP. JT. LINE 12 <br />1/2 WALL OR RAILING LIGHT TEXTURE 35 <br />jlLo� <br />2x4 WALL to DECO. FINISH0, <br />FAGARAGE sl��rlc F23 <br />F. FLOOR ELEV. 0'-0' <br />51JILDING 5ECTION <br />SCALE: I /8' =1'-01 <br />y a�aj`i <br />�'!9 i1� iiGd.iF.>Ytpb Q xi L.�fCq�Y,A� �: <br />h. <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www,do nscoengineering.com <br />CA 25948 <br />>t <br />o <br />0 <br />N <br />Z LU <br />H <br />O� <br />0 <br />Z <br />M M <br />M Ln <br />wL-LjP, <br />Z0 <br />z (- <br />W <br />(n <br />w <br />ZLU <br />0 <br />O <br />W <br />W Z Q> <br />0 > <br />= <br />CV) <br />OL d <br />W Q <br />0-0 <br />L U <br />0 ILLJ Q <br />�C o`1 <br />W CU1-0 <br />B M <br />Q <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd=108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />© 2018 LENNAR CORP.-THISS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02018-THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CUENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />12.13.17 <br />_ <br />1.00 6TH ED.(2017) FBC <br />UPDATES <br />_ <br />12.29.17 <br />1.01 PLAN REVISIONS TO HVAC <br />SPACE & ELECTRICAL <br />04.30.18 <br />1.02 REV. FLOOR TURSS LAYOUT <br />VERSION NO. 1.02 / 04.30.18 <br />0 `s .1.3 <br />< <br />S,. <br />a <br />. D1 <br />'. <br />�cI <br />00 <br />c� <br />oc <br />w <br />W <br />zi <br />ry <br />a Z <br />W <br />H dLID <br />w <br />NJ M 210 <br />Iw ) 4t: >- <br />Z Q ('-' z LLi <br />Uj ❑ <br />- <br />SHEET TITLE: <br />ELEVATION "B" EXTERIOR <br />ELEVATIONS 8,; ROOF PLAN <br />SHEET INFORMATION: <br />JOB NO.: 381319 <br />DATE ISSUED: 10.09.18 <br />DRAWN BY: JH <br />REVIEWED BY: TH <br />4B <br />PEW <br />W <br />CV <br />LO <br />