Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH WALL SHEATHING <br />I.. ... I [ <br />I( I <br />+.: .L.. <br />. <br />._.. <br />16GAx1-1\2" LONG (3/4"-1" CROWN) 8 <br />STAPLES @ 6" O.C. VERT BETWEEN MAX I 16GAx1-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:-) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" ¢ - <br />c" <br />STUB -OUT FOR 1'-O° 0 9 Ln <br />GAS METER O o <br />U <br />O <br />&4 = <br />11 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16' O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'4" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'41 <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x — <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 314" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />+ <br />Filler blocking ° <br />+ r� <br />1/8" gap r <br />FILL CELL STD. 900 HOOK BOND BEAM <br />U) <br />w <br />STD. 90° CONT. #5 <br />CONT. #5 <br />BAR <br />HOOK BAR <br />#5 CONT. <br />FROM <br />ON <br />TOUHIG HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION —TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" max <br />Clinch na <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails Zx4/Plywood/OSB web stiffener 2 min. <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2X TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING)/8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T,S: <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) —/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES EXCEPT <br />9 ' <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer <br />0 Load bearing walls when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below <br />Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />j, QY,� Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />J for each lapped joist. <br />blocking panel *Non -stacking walls <br />10dnails .SECTION_ @ INT. BRG. WALL requlreaddlttonalconslderatlon. <br />— <br />N.T.S. <br />( MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />0--L-0 ❑ <br />6r A %" ROUND HOLE MAY 6 6, DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %"ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9, THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />Web Stiffener Fastener Sched lu e <br />Joist BearingLocation <br />Series Depth End Intermediate <br />---- <br />BCI 5000so <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI6000so <br />BC16500so <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />1.6" <br />2-8d <br />6-8d <br />BCI60so <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190so' <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />aye .9 <br />Backer block (12" wide min.) IT1=tiT7.'4. <br />Nail with 10-10d nails.—j I I—nstall tight to top flange.SLEEVE THRU STEM <br />SEE PLAN FOR , :FOUNDATION INFO ' ° 4 ° <br />STEM FOUNDATION <br />u r—GRADE MErr,rE OCIM na nKE <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 2501bs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />0 requirements <br />0.6 X Joist <br />" ldepth <br />I -JOISTS BUCKETS <br />N.T.S. <br />.fill, t nmoC'+ rvu ' <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />:�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />�— PVC OR SCH40 SLEEVE <br />01 <br />- <br />e <br />f=ill=l <br />l f, l! Ill l l <br />, <br />-�---- SEE FND. PLN. <br />SIZE & REINF. <br />12° BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0"— <br />CENTERED @ PIPE <br />PENETRATION <br />//(////� PVC OR SCH40 SLEEVE <br />r—PLUMBING LINE <br />4 <br />4 <br />ZI _\ �® <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a' n . <br />=ill=1 11=I °4 1 4' = —: <br />l-1 <br />'E <br />ff <br />SEE FND. PLN. <br />SIZE & REINF. <br />cam+► <br />'w <br />2 <br />c <br />N w <br />m d v <br />C2.� <br />2 <br />M <br />0 <br />CV <br />0 <br />' <br />i <br />U-> <br /><s <br />17 <br />� f <br />4:, <br />`ti ZW cEE.• <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H <br />W <br />a <br />�E <br />0 <br />cD co <br />a <br />N coo o�v co0 .. <br />fA <br />inIr� <br />N} <br />a <br />M V LL <br />J LL LL u d <br />° <br />a <br />m rn vYi <br />.—mac <br />o� <br />Y o <br />3 co <br />WW <br />_ <br />IL <br />�26jO' m w <br />co Q J <br />N Z <br />N 0 <br />ZO <br />U U uu)i <br />W <br />o❑ <br />M <br />N M <br />og <br />co <br />N <br />� o � <br />U) <br />m <br />a- N <br />V) <br />M <br />2-1 v <br />0 <br />0 o <br />J_ <br />O <br />N <br />w o <br />�y N <br />t'a <br />2 <br />IL J <br />I <br />s � <br />d <br />cs o <br />° <br />N O� <br />o <br />w <br />� <br />cl> <br />M <br />oO g <br />r <br />z <br />� <br />u_ <br />tU E <br />g0 <br />QN <br />ca- ® <br />E U <br />Z <br />Z© <br />Od <br />� <br />�_ <br />ma <br />oo <br />U <br />23 E <br />p , <br />ao <br />o < <br />w, <br />0 <br />mo <br />o' <br />z <br />o <br />aw <br />zz <br />Jo <br />uz <br />O <br />m <br />� g <br />¢ <br />aE <br />S <br />¢ <br />_� <br />O <br />�r <br />zwo <br />¢ , <br />f Q <br />, m <br />o <br />c 0 <br />,o <br />> CO <br />N <br />0 <br />rn <br />m <br />C9 <br />(a Ln <br />� N <br />a <br />Ln <br />o.-IN <br />Q0' <br />Y <br />° <br />N <br />^ <br />LL <br />ca <br />N <br />- <br />co N <br />m <br />O <br />� <br />N <br />Q <br />o CN <br />r <br />.T <br />(� <br />r- <br />t'.O j <br />d <br />z <br />z <br />E T <br />u <br />w <br />c <br />@ <br />a- <br />E .. <br />ci � <br />v cc <br />Q o <br />c <br />c <br />°i <br />JOB <br />NO : <br />23-04904 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S N 1 <br />