Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1,1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />1 <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Qr <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />C11 <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />j I HANSON <br />BOX <br />I <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />I <br />---- — I I u W/C <br />LAV <br />J I 3" SHOWER <br />O <br />DISCONNECT <br />L TUB/ ti <br />W/C SHOWER �\ M. <br />3 �naF FLR <br />OUTDOOR LIVING <br />STUVENDOR DBL SINK \ C.O. INSTALL LIGHT �\��> <br />W/DISP. ROUGH -IN <br />2" FOR OPT. <�/ <br />LAV W/3„ 3, FAN/LIGHTI �' CFI <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 1 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />P I NEMAt <br />200 AMP <br />ETER MA N <br />1 �0-200 AM P I IT /—Serial Cable <br />NEMA <br />3R <br />Power Co. Feed �� IJ I- <br />#4 Solid COPPER Ground <br />I� <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />0 '1 <br />QDGFI <br />----- --- <br />DINING <br />KITCHEN 1 <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />>ROUGH -IN\ <br />f FOR OPT. <br />FAN/LIGHT <br />r� , <br />I I <br />I � <br />I <br />I� <br />I <br />I <br />I <br />C.M <br />1 UPSTAIRS C <br />-- <br />!, I • ■ . <br />FOYER <br />G <br />- \ <br />GFI <br />\ <br />@ 44" <br />W.H. <br />�- <br />A.F.F. <br />\ 0 <br />I <br />� <br />1 <br />ENtRY I WPDB <br />I GARAG E <br />LIGHT AS U GFI <br />I <br />I <br />PER SPECS <br />DB&GFI TO <br />1 <br />- _ <br />BE ALIGNED <br />GARAGE <br />VERTICALLY <br />LIGHT AS <br />--- <br />NPER SPECS <br />- <br />GARAGE <br />\-& <br />DOOR <br />_ <br />GFI <br />I -- <br />I r----------------- <br />I <br />W <br />1 <br />bZ <br />I <br />\ <br />20Iz <br />>- <br />NU <br />I <br />I <br />W <br />Ird <br />W <br />j�m <br />Dw <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL — <br />UNIT —A 1532 <br />SCALE: Y"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL — UNIT —A 1532 <br />SCALE: Y4"=1'-0" <br />H <br />c, <br />a'w O <br />C-2 CL CC <br />G M C' N <br />�.co x <br />H �.L Z <br />t <br />®ID <br />C <br />C14 Cc <br />3=:'yaC <br />y a a, <br />rO 3 3to <br />m dr .o <br />d = c <br />an Ct a <br />o � <br />o <br />O <br />CI), <br />O <br />N <br />0 <br />��..LE <br />01 <br />.. pp <br />CO <br />' f <br />No P <br />837 <br />%& <br />�}�•• STATE <br />OF .ft <br />°r <\ °' • <br />R �`• <br />0 <br />00 <br />PBl9►�l <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0) <br />W <br />Q <br />E cj <br />O M y N 3 <br />ci <br />N O m <br />S� -'0 N #"LL <br />fq <br />u <br />d a <br />Q <br />ce)04UJ <br />V <br />J Li rL Y 0 <br />CoLL <br />t9 <br />—drn00 <br />r � coLo <br />m Lu <br />Q <br />O��m d 0 Z <br />Z <br />W <br />LL <br />IL <br />W <br />N cM Z U G H <br />0 <br />O U ❑El❑ <br />Z <br />W <br />(D <br />N Q <br />o S <br />eD <br />� o <br />Q� <br />J <br />to <br />N <br />M <br />z <br />(D <br />v <br />o <br />a-J <br />0 <br />�N <br />w o <br />U <br />W J <br />r— — E <br />S <br />w N <br />Pypy <br />in <br />Q 0 <br />0 <br />N <br />o <br />Cl> <br />M <br />y <br />o <br />w <br />Z <br />Q <br />E <br />fl O <br />zo <br />�o <br />" <br />>� <br /><� <br />z© <br />t- M <br />Q E <br />U <br />U <br />Oa F <br />00 <br />Q 0 <br />0 <br />`� <br />Qo <br />< <br />ww <br />cQ <br />�' <br /><z <br />0< <br />O V <br />m o <br />0& <br />Z <br />m J <br />Nm <br />10- <br />F <br />> <br />`gn <br />8< <br />Z <br />�o <br />c <br />Z <br />o <br />�w <br />= <br />>° <br />v <br />ol¢ <br />a <br />0 3 <br />o T <br />> o6 <br />m <br />N <br />CD <br />Co <br />i— <br />(1) <br />00 <br />C.r <br />L <br />Co r\ <br />T_ <br />T <br />r <br />6r0 <br />Co <br />,�-- <br />p <br />Ln <br />00 <br />0O04 <br />O <br />O <br />Cfl <br />r <br />E <br />M <br />M <br />N <br />o <br />o <br />Z <br />Z <br />E f— <br />N T <br />M <br />@ <br />E <br />c <br />JOB <br />NO: 23-13137-13142 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />■ <br />