Laserfiche WebLink
LO <br />4M <br />.0 <br />to <br />00 <br />1� <br />Q-C, <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36"AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42"AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance With FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />L4�4_ <br />vkz:;�_ <br />DUPLEX CONVENIENCE OUTLET <br />Lz±i, <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />�I@W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />1 4::� <br />I";='G . F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I 0=� <br />I'llI111111101- <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />1 1;4V <br />SPECIAL PURPOSE OUTLET <br />ta <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />)::�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />I­_0 <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RCH <br />CHIMES (OPTIONAL) <br />IfE <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />X;>% <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE Wif ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14.250.94 <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to rights & outiets <br />NEMA 1 <br />200 AMP 10 #12 copper to 20 amp ckts <br />01 #10-2 copper to WH <br />10 # 10-3 copper to Dryer <br />METER T <br />n r 2/0 or 4/0 SER AJu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />U^^rl% nr!rlj orliffVIC. <br />SYSTEM <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />1/1 ID <br />M <br />0 LU <br />LU <br />:u <br />< <br />< <br />A I <br />MD. <br />Uoz <br />Ole Ace W a! <br />UJ jig-.1 11; 1 <br />LU < <br />Z <br />Z 2 E <br />'M T <br />UM <br />LU c-, <br />WWW.FDSENG.COM U U <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Enginear's signature and real. <br />LE PJ NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />1 8 <br />Of � <br />'u <br />0 ce <br />Z <br />< <br />w <br />00 <br />0 <br />Z <br />%*.000 <br />L.0 <br />W <br />0 <br />0 <br />U <br />0 <br />_j <br />Z <br />Z <br />Lu <br />Ln <br />Lij <br />Z <br />ca <br />to <br />06 <br />Z <br />Z <br />UJI <br />0 r_1 <br />, <br />0 <br />SCALE AS NOTED <br />DATE 10/2/2018 <br />TECH: MJAMES <br />VERSION No' 4nO <br />SHEET NO. <br />4.0 <br />