Search
2988 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2988 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:23:55 PM
Creation date
2/19/2025 10:42:30 AM
Metadata
Fields
Template:
Building Plans
Street #
2988
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20749
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1 . Cut, fold up & temporarily secure weat <br />barrier above header to allow for flashing <br />THESE DETAILS ARE GENERIC AND <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />BE USED. <br />flashing and seal with tape <br />Scale: NTS <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNIQL <br />LETTER ON CHEM CAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />") WEATHER <br />VE BARRIER & <br />tARILY SECURE <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHING <br />3/4"A" BEAD OF CONSTR. <br />SHEATHING <br />BY LAPPING DOWN <br />ADHESIVE TO BE APPLIED UNDER <br />OVER RIM JOIST A14D UP <br />THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />WEATHER <br />SELF -ADHERED FLASHING <br />RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />SUBFLOOR <br />ED FLASHING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />NAILING FLANGE <br />2 <br />DO NOT FLASH OVER <br />BOTTOM NAILING 8 <br />FLANGE <br />Z <br />F3 <br />.0 <br />NOT USED <br />ri I <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"A"BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />I <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SHEATHING <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />M SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />3" MIN <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED <br />2 <br />4 <br />5 <br />WINDOW UNIT <br />SLOPE <br />0.3 in : 12.0 in <br />(0. 6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />FLASHING SELF -ADHERED FLASHING <br />MEW <br />10- <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />FOUNDATION WEEP SCREED <br />NOT USED <br />SCORED P - ------- 1,� <br />RELEASE APER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. Onelayerof No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226forType 1 feltor <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (1152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1 - 1 The fenestration manufacturer's wdtten flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMAIWDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projedrig lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as 0 in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />/0"*N WEEP SCREED DETAIL <br />kI..J SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTIVIC 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0- <br />:Z <br />V) 0 <br />C-0 <br />4--J <br />0 LU <br />(_n 17� <br />V) <br />81 <br />P <br />LL. <br />< <br />Al I <br />BID. <br />1WI-1 V <br />10 <br />42 8 6 <br />Z0 <br />Ed <br />LU <br />Lu ri JU A_� <br />10Z <br />0 <br />ro <br />Z <br />WL <br />W <br />WWW.FDSENG.COM 130 <br /><=) <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. EngIneer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L E N NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />1T5 <br />9 <br />(04 <br />Z <br />C/) <br />> <br />UJ <br />C) <br />Z <br />Z <br />2: <br />C <br />cu <br />LIL <br />0 <br />2: <br />0 <br />0 <br />cc <br />U <br />CL <br />CC <br />LLJ <br />R8 <br />1:� Q <br />198 <br />4 <br />< <br />dog <br />8 1 <br />-4 <br />Z <br />UJ <br />_J <br />Lr) <br />V-4 <br />di <br />< <br />f%4 <br />00 <br />C-4 <br />Z <br />Z <br />t <br />CIO, <br />06 <br />Z <br />""; <br />UJI <br />rn <br />T-4 <br />0- <br />Ln <br />S <br />SCALE AS NOTED <br />DATE 10/29/2018 <br />TECH: MJAMES <br />VERSION NO 4mO <br />SHEET NO. <br />W P <br />I I <br />