My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2988 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2988 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:23:55 PM
Creation date
2/19/2025 10:42:30 AM
Metadata
Fields
Template:
Building Plans
Street #
2988
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20749
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P, <br />.0- <br />�R <br />C'4 <br />.0 <br />I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44"AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be In accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />1-=lk- <br />I t7l` <br />DUPLEX CONVENIENCE OUTLET <br />I.An' <br />F14F <br />DUPLEX OUTLET ABOVE COUNTER <br />0W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />I Znk. <br />PE5G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />L /-\.. <br />FFEF <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph <br />I r"AV <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />CS . <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />)::�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCHI <br />CHIMES (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />09 <br />ELECTRIC METER <br />A1111071 <br />ELECTRIC PANEL <br />Masi <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14,250.94 <br />200A INDOOR PANEL <br />CENTER <br />b #14 copper ioWhla& outlets <br />NEMA 1 <br />200 AMP 10 # 12 copper to 20 amp cirts <br />10 #10-2 copper to WH <br />10 0 10-3 copper to Dryer <br />METER T <br />n r 2/0 or 410 SER AJu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />LU <br />0 LU <br />120 <br />U-1 <br />E <br />Al I <br />ISTM <br />so <br />Ci 1-:1 0 <br />U) 3 Z Z <br />lase <br />C9 W <br />LU <br />Lu <br />Z 0 0 <br />ease! <br />Z <br />LU <br />U U <br />VAM FDSENG COM <br />00 <br />C=) <br />C14 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specificatIons contained within these <br />drawings comply with the 2017 Floirlds Building Code - <br />Residents[ 8th Edition, Engineer's signature and seal is only for <br />the structuml engineering portions of the drawing pages bearing <br />Engineer's signature and seat. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z -C <br />C� <br />00, <br />W <br />Z <br />> <br />CL <br />Z <br />Z <br />easeellt. <br />0 <br />LItes <br />cc: <br />U <br />b <br />LU <br />Uj <br />P r <br />:6 <br />C%j <br />Vessel <br />< <br />Z <br />U. <br />Z <br />LU <br />Ln <br />Lij <br />NZ <br />r_4 <br />00 <br />C"4 <br />< <br />Z <br />Z <br />0 <br />06 <br />Z <br />4-� <br />LU <br />rn <br />-r-4 <br />10. <br />1 Ln <br />E <br />SCALE AS NOTED <br />DATE 10/29/2018 <br />TECH: MJAMES <br />VERSION No' 4n0 <br />SHEEr NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.