My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3111 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3111 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:35:22 PM
Creation date
2/19/2025 10:43:13 AM
Metadata
Fields
Template:
Building Plans
Street #
3111
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19243
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />I.Z=S <br />FEF <br />DUPLEX CONVENIENCE OUTLET <br />I e±, <br />FTF <br />DUPLEX OUTLET ABOVE COUNTER <br />L=%_ <br />r1V`w.P. <br />WEATHERPROOF DUPLEX OUTLET <br />1.0=:)i <br />1'�='G . F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />F't�-V <br />SPECIAL PURPOSE OUTLET <br />171n <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RCH <br />CHIMES (OPTIONAL) <br />ID <br />PUSHBUTTON SWITCH (OPTIONAL) <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />_11111IF-i <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />1> <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP #12 copper to 20 amp ckts <br />#10.2 copper to WH <br />#10-3 copper to Dryer <br />M_A,I N <br />0 <br />2/0 or 4/0 SER AJu <br />200 amp <br />150 amp <br />IDDlaconnectl <br />POWER CO. FEED-1 <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />RECEPT. <br />FC <br />— — — — — — 51 <br />UPPER ELECTRICAL PLAN <br />SCALE: Y4"= V-0" <br />0 <br />Z C') <br />— 8 <br />Z W <br />Z <br />CL <br />LJO (D <br />Z <br />L.0 <br />C) <br />0 L.Lj <br />V) <br />E <br />0 <br />2 <br />Ln <br />0 <br />00 <br />F0 r- <br />C14 <br />co <br />ILLJ <br />j..- E <br />— 8 <br />co ce) <br />C W 1:1) <br />E! :S cl, <br />0 _6 ", <br />:3Z <br />U <br />LL. 00 <br />-00 <br />0 2 g <br />CO CL <br />< <br />if) 0 'r <br />A I <br />N 0,11,11 1, <br />0! <br />Z 'C' Z0 <br />M 0) c=) <br />9: — - § — <br />LL. <br />cm <br />90) <br />ease di L�: V <br />CL LLj <br />W <br />Z 0 vct) 4m <br />C < <br />2F <br />Z <br />LLW o) <br />04 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and sea[ Is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seat. <br />C) <br />0 <br />Z C4 <br />0 CU N <br />)-4 4-J <br />%0 <br />U <br />V) f0 Ln <br />Z <br />V) ON <br />— Ln <br />U_ <br />a> " <br />F- � <br />CL 00 <br />Z <br />E <br />Z fo <br />Z <br />LU <br />LU <br />Milli <br />Ul <br />Z <br />Ln <br />LU <br />LU <br />0 <br />0 <br />U <br />0 <br />-j <br />LL_ <br />0 U. <br />lu- R <br />< " <br />0 <br />510-1 <br />Z <br />UJ <br />Z <br />LU <br />Ln <br />Lij <br />CYX <br />��.O� <br />--I <br />I 6j <br />X <br />Z <br />HQ <br />00 <br />< <br />Z <br />Z <br />17u <br />0 <br />Z <br />UJI <br />Z <br />0 <br />SCALE AS NOTED <br />DATE 2/24/2014" <br />TECH: MIAMES <br />VERSION NO - 10 <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.