Laserfiche WebLink
TYP @ 2 STORY <br />H.B.__ <br />43'-0" <br />(3) 2X4 #2 SPF W/ (3) 16d <br />TOENAILS @ BASE <br />EN )D. <br />=j <br />I <br />I I <br />I 110117118 <br />111 <br />TYP @ 2 STORY <br />I I I (IG <br />[S-3 <br />UP 115H I <br />I I I I <br />C? <br />4 1 5 111 11 7_18 <br />50 <br />FLOOR G.T. <br />. I I . 1. 1 .. <br />9 <br />FAMILY ROO M <br />8'-8" FLAT CLG. <br />CARPET '9 <br />+42" SLOPING 0 10 <br />HALF WALL 11 <br />(3) 2X4 #2 SPF T P <br />W1 (3) 16d <br />TOENAILS @ <br />BASE <br />�-8 <br />rG <br />00 <br />CD <br />00 <br />o? <br />9 <br />FLEX <br />8'-8" FLAT CLG. <br />CARPET <br />co <br />o? <br />-W <br />LO <br />cl) <br />4'-0" <br />C� <br />(2) #5'S c- <br />2x6 <br />5-SH <br />C? <br />9 <br />2" DEEP <br />- <br />- - - - - <br />L? <br />2068 B.F. <br />to - - - - - - <br />HDR AT T-4" <br />- - - - - - <br />ENTR <br />16'43g" <br />T-8" <br />T-13" <br />6-0" L­2� - <br />FLAT CIL <br />di <br />FOYER <br />(D <br />Z' <br />TYP @ 2 STORY <br />(3) 2X4 #2 SPF W1 <br />(3) 16d TOENAILS @ <br />AV- BASE <br />10 <br />9 Cn <br />(0 00 <br />u') DINING ROOM <br />8'-8" FLAT CLG. <br />PATIO <br />CARPET <br />0 <br />U_ <br />cri -1 <br />0 01 LO <br />1 0 <br />U_ L.Li <br />8'-8" FLAT CLG. <br />TILE <br />3068 1 1 <br />I <br />- - - - - - - <br />#5 <br />9 <br />CD <br />.... <br />9 <br />=LL'. <br />....... <br />/(3 2X4 #2 SPF W/ <br />( ) <br />3) 16d TOENAILS <br />@ BASE <br />2'-6" L BUILDER TO PROVIDE <br />APPLIANCE PROTECTION <br />WHEN REQUIRED PER FBC <br />2 CAR GARAGE <br />cc <br />��3� <br />F - - - - - - <br />I D <br />I S3 <br />4' 0" <br />C� <br />AV- <br />8'-8" FLAT CLG. <br />4'-0" 6-2" 6-6" <br />4'-8" <br />20'-8" <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />CN <br />cc <br />0 <br />0 <br />W <br />0 <br />C) <br />F] F1 <br />L <br />L- - - - - - - - - - - <br />3 36 36 .3 <br />CIO: <br />C14 <br />X <br />[Ell <br />__KJTCHEN <br />Ile <br />T-8" FLAT <br />CLG. <br />lit <br />1 <br />--ULF <br />1 <br />2� �68 <br />2668 <br />Eo <br />1 <br />ki <br />24 24 <br />2x6 WALL <br />L - - - - - - - - - - - - -- <br />REF. <br />OPT. <br />PANTRY <br />9 <br />16" DEEP <br />5-SH <br />I I <br />I I <br />I <br />11771111111111111111111111111111111111111111111177717 <br />111111111111011111111 I'T <br />I I I 1101111111111101111111 <br />IZ11 <br />)TYP @ 2 STORY H.B.� <br />5' <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X1 0 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X1 2 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 1 314" X 11 1/4 LVL <br />2.OE Fb=2950 <br />(2) - 13/4" X 9 1/4" <br />LV`L 2.OE Fb=2950 <br />(2) - 1 3/4" X 16" <br />LVL 2.OE Fb=2950 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.OE Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X25i <br />S.H. <br />13 <br />20 X 38J <br />184X37i <br />S.H. <br />14 <br />20 X 501 <br />184X50 <br />S.H. <br />15 <br />20X63 <br />184X624 <br />S.H. <br />16 <br />20 X 72 <br />18 j X 71 <br />S.H. <br />J32 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />433 <br />27 1/4 X 38 <br />N/A <br />S.H. <br />434 <br />27 j X 501 <br />N/A <br />S.H. <br />433 <br />N/A <br />26x37i <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />J35 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />J36 <br />274X72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 j X 26 <br />36 X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />364X50 <br />S.H. <br />25 <br />37JX63 <br />36 j X 62 1/2 <br />S.H. <br />26 <br />37 JX 72 <br />36 4 X 71 112 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />734WIDE <br />S.H. <br />32 <br />54 X 26 <br />52JX254 <br />S.H. <br />33 <br />54 X 38 <br />52 4 X 37 j <br />S.H. <br />34 <br />54 X 50 <br />524X50 <br />S.H. <br />35 <br />54 X 63 <br />52 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.K <br />General notes <br />R302.5 Dwelling/Garage OpeninglPenetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 13/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.1 1, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is located.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M 1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />+25.6 -27.8 <br />+25.6 / -34.3 <br />+24.5 -26.7 <br />+24.5 / -31.9 <br />+23.0 -25.2 <br />+23.0 / -28.9 <br />SEE SN SHEET SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE <br />IS AN "ULTIMATE" WIND SPEED, THE <br />WIND PRESSURES LISTED ABOVE ARE <br />ALLOWABLE PRESSURES <br />WALLLEGEND <br />11111111111111iff MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />W 1� I I I I I BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 11131 <br />11 <br />1ST FLOOR LIVING AREA <br />1093 <br />2ND FLOOR LIVING AREA <br />1489 <br />LIVING TOTAL <br />2582 <br />GARAGE <br />427 <br />FRONT ENTRY <br />35 <br />TOTALAREA <br />3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-1 1 /R-1 3 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-1 I/R-13 KRAFT FACED <br />(GARAGE I LIVING) <br />LO <br />0 <br />Z M <br />C) <br />C> <br />z <br />z <br />__j <br />U) z <br />4--J LU <br />U <br />0 LLJ <br />E <br />v) <br />V) <br />0 <br />W <br />Cn C') <br />(13 0 <br />.90 <br />LU <br />E <br />8 <br />CD M <br />0) cl) <br />C cum <br />ca (n <br />, 04 <br />000 <br />aj <br />U) <br />= M 00 <br />0 <br />U) CL c:3 <br />< 00) <br />U) 0 <br />-MT <br />D" <br />N C-B-D C <br />co <br />cli <br />0 <br />.0 <br />W I C"8 Z <br />11 _0 _,� z <br />0, <br />-LLJ <br />ul <br />5 LL <br />& <br />a) C LL <br />ul > 0 <br />6 <br />z <br />0 "0 401 <br />U) 40 9-'..., <br />.e C cq 0 <br />'M 0 <br />Ijp <br />Z, E <br />< Cl) <br />0 <br />F <br />El E] <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. EngMeer's signature <br />and seal is onlyforthe structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />I <br />z <br />0 <br />4-J <br />=5 <br />> U.) C�' <br />4-1 <br />U-) rO Ln <br />tn 0 <br />a) - Lr) <br />L_ LL <br />z0_ <br />Q) CL OC) <br />< <br />z § E <br />ro <br />z <br />Lu C� <br />_j C:) <br />W <br />kD <br />,z <br />0 <br />z <br />U480 <br />bow <br />Z Lu W <br />Z <br />I <br />0!� z <br />LU <br />1 0 <br />Uj <br />�n <br />z Z <br />Cl) <br />.2: <br />_j <br />0 <br />z <br />z <br />0 <br />z <br />D <br />Ln <br />__j <br />4 <br />LL_ <br />'0 <br />Ln <br />z <br />0 <br />U <br />r-4 <br />< <br />Lu <br />LU <br />8 Z <br />x <br />LUU 0 <br />t:! E W CL <br />r,4 <br />0 <br />, �< R �, <br />LU W <br />< <br />(D < <br />uj <br />z <br />z <br />Ul <br />20: <br />LU <br />Ln <br />-I <br />L]j <br />=< <br />�z ou <br />Lij <br />2: <br />< <br />OP <br />E �2 V <br />LLJ g <br />c) <br />V_ <br />1,10 <br />< <br />z <br />z <br />" <br />9-. 2t <br />cyj <br />03 <br />Ln <br />Z <br />LU <br />V) Z <br />0 <br />'71 <br />0 <br />X: <br />z <br />LLJ <br />U')- <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: MIAMES <br />VERSION No' 10 <br />SHEET NO. <br />1.0 <br />