CROSS BRACING DETAIL (TYP.)r <br />SCALE: 1/2" 1' <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1 . WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS-----7 <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS <br />MAX & EACH END ALTERNATE <br />DIRECTION TYP. <br />----/--WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1/2"=V-0" <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />=01 <br />rklfx <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />—TRUSS OR <br />ROOF SYSTEM <br />SHEARTRANSFER <br />EXTERIOR. WALL <br />SCALE: 3/4" = V-0" <br />CB <br />vvl I vv VW "��l I I I 1� v v <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />- 2x8 BLKING. NAILED @ EACH <br />SIDE W/ (3) 12d NAILS WHEN <br />REQUIRED W/ (2) USP HTW20 <br />W/ (14) - 1 Od X 1 1/2" EACH <br />TB <br />7 PRE-ENG. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIAGONAL <br />AT 81-0" <br />MAX <br />WOOD <br />TRUSS <br />SEE ROOF <br />SHEATHING <br />PLAN <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />"19. <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP, <br />TRUSS <br />HIP <br />G.T <br />AT 12" O.C. MAX <br />(2) 12D NAILS <br />HIP/RIDGE BLOCKING DETAIL <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 1 Od TOP & <br />BOTTOM OR USP RT7 <br />OR HCLR/LL W/ 8 - 8d <br />IN PLACE OF (4) 10d <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR USP RT7 @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-O"O.C. MA)C W/ (3) 1 Od <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT--/ CONC.MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A —A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />SCALE: 1/2" l'-O" <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />OIL VARIES <br />ROOF SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 #2 SPF BRACING @ <br />16" O.C. W/ (4) 12d <br />COMMON TRUSSES. <br />TOENAILS TO TOP <br />SEE TRUSS PLAN <br />PLATE & (2) 12d END <br />NAILS TO TRUSS <br />MIN. (2) 2XI4 <br />SPFTOP <br />FPLATE <br />FOR CONNECTION <br />INFORMATION. <br />BOTTOM CHORD <br />4VARIES SEE PLAN <br />FOR WALL LOCATION <br />MIN. 2X4 #2 SPF STUDS @ <br />16" O.C. W/ EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE & <br />(3) 12d TOENAILS TO <br />SEE PLAN FOR <br />PLATE BELOW <br />TOP OF WALL <br />MIN. 2X4 #2 SYP P.T. PLATE <br />W/ 1/2"X8" EPDXY ANCHOR <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />PLAN FOR MORE <br />16" O.C. MA)C <br />INFO. <br />SECTION <br />@ ENTRY <br />SCALE: 3/4" = V-0" <br />USP LSTA18 <br />CENTERED @ <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />SCALE: 1/2"=V-0" <br />USP HD4101F BUCK -- <br />SEE ROOF PLAN F1 <br />MORE IN <br />(2) 2x8 #2 SYP W <br />7/16" O.S.B. FLIT <br />PLATE TOP @ T1 <br />BRG. <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN W/ (2) HTW20 <br />STRAPS <br />USP JUS46 OR JUS461F <br />BUCKET TO COLUMN <br />SUPPORT COLUMN BUILT-UP <br />(2)-2x4's OR 4x4 W/ (2)-1 Od <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) USP HTA20's <br />w/(l 0)-1 Od x 1 1/2 EA. TO COL. <br />ALT: (2) USP MSTAM36 <br />STRAPS CENTERED <br />w/(l 3)-1 Od NAILS Ea TO COL. <br />TIE BEAM <br />BEAM RAISED ENTRY <br />MASONRY WALL rl�A <br />4 <br />SCALE: 1/2" V-0" <br />kSEE PLAN <br />FOR CANT <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE& BASE L-7/16" OSB FLITCH PLATE <br />CONNECTION INFO REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7/16" OSB FLITCH PLAI E SEE FLOOR PLAN FORJ SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE& BASE <br />INDICATED ON BM. CONNECTION INFO <br />OPTION A SCHEDULE/PLAN OPTION B OPTION C <br />COMMON BM. TO POST ATTACHMENT <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />USP ST18 <br />TYP. U.N. 0. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />2X4 STUDS W/ USP - <br />SPT22 @ BASE SEE <br />J/S6 FOR MORE <br />INFO. <br />A F_� A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />0. <br />0 <br />CORNER SEE FOUNDATION <br />< PLAN FOR MORE INFO <br />COMMON BM. ATTACHMENT <br />SCALE: 314"=V-0" <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />USP LSTA30 OR <br />MTW12 TO FLOOR <br />GIRDER BELOW @ 16" <br />O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION r2 2* � <br />SCALE: 3/4" = V-0" <br />SCALE: .914"=V-0" <br />SEE VS5 FOR <br />ADDITIONAL <br />OUTLOOKER <br />INFO. <br />jgi <br />GABLE <br />TRUSS <br />1/2" PLYWOOD <br />(2) 16d NAILS TO <br />EACH COMMON <br />TRUSS/ FRAMING <br />TYP TOP & BOTTOM <br />BM. SPLICE OVER <br />//—CENTER OF POST <br />MIDDLE <br />8d NAILS AT <br />4" O.C. <br />SEE PLAN FOR <br />VALLEY TRUSS <br />INFO. <br />MASONRY WALL BELOW: USP <br />44. <br />HTA1 6 @ 4'-0" O.C. TO GABLE <br />MASONRY WALL TRUSS BEAM BELOW: USP <br />OR BEAM HTW20 @ 4'-0" O.C. TO GABLE <br />SEE TRUSS PLAN ------- <br />TRUSS <br />7T--=i <br />OMMON TRUSS <br />SEE ROOF PLAN <br />FOR CONNECTION <br />SECTION AT HIP GABLE <br />SCALE: 3/4" = V-0" <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />�CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE DETAIL 41D1 <br />FOR BEAM SIZE <br />EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />2x SPF #2 <br />AT 16" O.C. <br />KNEEWALL <br />2X4 #2 SYP NAILER. NAIL <br />TO STUDS W/3-16d @ <br />EA. STUD. TOENAIL EA. <br />TRUSS TO NAILER W/3-1 Od <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />ENTRY FRONT WALL <br />SCALE: 1/2" V-0" <br />USP JU26 OR IF 2 PLY <br />TRUSS USP JUS26-2 <br />TRUSS TO LEDGER <br />2X8 #2 SYP CONT. LEDGER W/ <br />(4) 16d NAILS ATTACH NAILS <br />INTO END OF EACH FLOOR <br />TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL <br />(4) NAILS EACH SIDE) <br />ROOF AND EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />SEE FLOOR FRAMING <br />PLAN AND J/S6 FOR MORE <br />INFO. VERIFY WITH PLAN <br />FOR LOCATION AND <br />DIRECTION (IF PARALLE <br />SEE 2/D2 FOR BLOCKING <br />INFO) <br />-MASONRYWALL <br />(TYPICAL) <br />SECTION AT LOW ROOF <br />SCALE: 1/2" l'-O" <br />LOW ROOF/WAL <br />L <br />SHEATHING ATTACHED\ <br />PER NAILING SCHEDULE <br />2x STUDS @ 16" O.C. <br />W/ USP SPT22 @ <br />BASE & SPT24 @ TOP <br />2x BLOCKING BETWEEN <br />STUDS TO TRUSS W/ (2) <br />12d TOENAILS EACH END <br />(BETWEEN TRUSSES (2) <br />12d NAILS TO EACH <br />VERTIVAL STUD) <br />2x BASE PLATE W/ (2) 12d <br />NAILS @ 16" O.C. ALONG W/ <br />USP MTW1 2 TO BLOCKING <br />BELOW @ 16" O.C. <br />PLYWOOD <br />FLOORING <br />LOW ROOF TRUSS W/----/ Z- (2) 2X6 BLOCKING UNDER� FLOOR G.T. <br />RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN <br />EXTENSION SEE TRUSS JUS24-2 EACH END <br />MANUF, SPEC'S FOR <br />CONNECTIONS TO G,T. <br />SECTION @ BUMP OUTK '39'N� <br />SCALE: 3/4"=V-0" <br />DETAILS & SECTIONS <br />0 <br />0 <br />0 <br />z CO <br />< <br />z <br />V) (D <br />C—n <br />LU <br />U <br />0 LU <br />E <br />Ln <br />v) <br />0 <br />0) <br />U) co <br />00 <br />Fn r- <br />N <br />U_j <br />E <br />8 <br />W ce) <br />c" C0 <br />C: M Cl) <br />T "Q CO <br />0 8 NO <br />UM) <br />00 <br />0 _,2 rz <br />0 <br />a <br />U) CL 0 <br />Lo 0 <br />Iq 0. <br />0) < 0 <br />A I <br />N c'B D-C <br />X% <br />N 0. <br />�z <br />2—PWI, .0 <br />Rvi C2 — <br />0 <br />ffu< <br />q Cj <br />FL01Cv'c04�, <br />.47 <br />z <br />LL U, M <br />Mo in E S S I <br />X_ <br />%11111111110 <br />W k*N <br />0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C) <br />C) <br />z r%j <br />0 a) N <br />1--j 4­0 C:) <br />Ln 5 t.0 <br />C) <br />> V) M <br />ro p <br />4­;� N <br />f0 Ln <br />v) �5 N <br />(1) — Ln <br />< L_ LL <br />� ro <br />01-1 U <br />00, <br />z <br />z E <br />z <br />LU C) <br />_j 0 <br />W 1.0 <br />0, <br />1,0" <br />0� <br />Z, <br />4 8 C) <br />One <br />U.J Lu <br />zuz< <br />:3zz <br />Lu <br />E U) <br />go <br />0 �� <br />'lu <br />U) <br />7: <br />Z Z <br />8 <br />> <br />0 <br />z <br />lcl� <br />C: <br />Ln <br />C) <br />LU <br />F <br />0) <br />_0 <br />U) <br />8 <br />a <br />0 <br />-6 <br />Ln <br />06 <br />z <br />::1 < <br />U <br />W <br />_j <br />< <br />9W <br />7 <br />W9 <br />�51 . <br />r- R 0z <br />k-r- <br />LL] <br />5<86 <br />u, Ow <br />Ce <br />r-4 <br />C) <br />< g�c <br />R.07<, <br />11" <br />,-C, I - uccl <br />8 �u 2: <br />z <br />z <br />N <br />T-4 <br />2,09g <br />ujzl� <br />'= <br />LU <br />Lr) <br />< <br />< <br />z <br />�j 2 =z, <br />R�P-ZB <br />2 �� �i <br />LU �0- <br />!� z <br />C) <br />Z <br />z <br />U <br />M <br />CY <br />M Z <br />0 <br />:5 <br />Uj <br />zj 0 <br />rn <br />z <br />SCALE: AS NOTED <br />DATE 2/24/2014 <br />TECH: MJAMES <br />VERSION NO' 10 <br />SHEET NO. <br />D1 <br />z <br />