My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35885 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35885 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:46:07 PM
Creation date
2/19/2025 10:44:14 AM
Metadata
Fields
Template:
Building Plans
Street #
35885
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
21166
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-TEMPORARY TAPE <br />r-LAP' Z/ TO HOLD FLAP 2HOU5E <br />4,1 WRAP 7 <br />bH A NG <br />ROUGH <br />OPENING <br />HOUSE <br />WRAP <br />SHEATHING <br />-TEMPORARY TAPE <br />'TFLAP' _\ X/ TO HOLD FLAP /wOU6E <br />WRAP/ <br />SHEATHING <br />ROUGH <br />OPENING <br />141 <br />HOUSE SILL WRAP __\ i-,ILL FLASHING <br />WRAP INSTALL FLEXIBLE <br />FLASHING <br />SHEATHING WI;NEI;6 AT <br />WINDOW SILL <br />WINDOW IFLAN( ;;E <br />WRAP <br />'FLAP' <br />TEMPORARY TAPE <br />TO HOLD FLAP <br />4,1 /wm6E <br />WRAP7 <br />SHEATHING <br />CAULK BEHIND <br />WINDOW FLANGE <br />BEFORE <br />INSTALLATION. <br />r--51LL FLASHING <br />WINDOW FLASHING METHOD -A-1- 3-STEP PROCESS: WINDOW FLASHING METHOD -A-1- WINDOW FLASHING METHOD -A-I' <br />A A WINDOW INSTALLER WILL CUT THE BUILDING PAPER AT A 45. ANGLE TO A POINT V UP AND 9' OUT A. INSTALL SILL FLASHING (EXTENDING 4'BEYONE) THE ROUGH OPENING ON EACH SIDE) A, APPLY A CONTINUOUS BEAD OF CAULKING ON THE BACK SIDE OF THE WINDOW FLANGE. <br />FROM THE UPPER COI;NER5 OF THE ROUGH OPENING, (�) 5. INSTALL CORNER SHIELD FLASHING (FASTEN WITH MOISTOP SEALANT OR EQUAL) B. INSTALL THE WINDOW ACCORDIWG TO THE MANUFACTURERS SPECIFICATIONS. <br />5. TH15 WILL MAKE A 'FLAP' THAT WILL BE USED TO COVER THE HEAD FLASHING IN STEP 6, C. INSTALL SILL WRAP (MUST COMPLETELY COVER ROUGH OPENING SILL (INCLUDING COI;NER SHIELDS) <br />METAL FLASHING <br />DOUBLE LAYER SPLINE APPLIED <br />VERTICALLY (IF U51NG FELT, SPLIT <br />3V - WIDE SHEET IN HALF) <br />2' TO 4' LAP AT <br />HORIZONTAL JOIN <br />2' TO 4' LAP AT <br />IN IN <br />HORIZONTAL JOINT <br />IN <br />614EATHING__�� <br />IN <br />BUILDING PAPER <br />HOU6EWRAP <br />"IN <br />I -CUT <br />IN <br />WINDOW <br />OPENING5 IN <br />SHEATHING WRAP <br />(BUILDING PAPER <br />OR HOU5EWRAP) <br />CARRIED V TO 2' <br />IN <br />BELOW 50TTOM <br />OF SHEATHING <br />IN <br />I <br />4' TO 6' LAP AT <br />VERTICAL JOINT <br />9'(6' MIN.) BEYOND <br />COI;NER 5OAFV <br />WRAP DETAIL <br />,SHEATHING <br />SCALE: N.T.5. <br />TEMPORARY TAPE <br />%AP' TO HOLD FLAP /WOJSE <br />WRAP7 <br />HEAD FLASHING <br />JAM FLASHING <br />WINDOW FLANGE <br />HOUSE <br />WRAP <br />SILL FLASHING <br />WINDOW FLASHING METHOD 'A-1- <br />A. INSTALL HEAD FLASHING OVER THE WINDOW FLANGE. <br />B. EXTEND THE HEAD FLASHING VIBEYOND THE ROUGH OPENING ON EACH SIDE. <br />To Z(�,M_0,1,5,T`U,Rf`T"O' WE D'1vERTiD`T`O T_H,EO,UT51E3E5`UW,, A"C"i <br />-TEMPORARY TAPE <br />'FLA <br />; P' TO HOLD FLAP <br />4N1 /WCU6E <br />WRAP/ <br />SHEATHING <br />'10 /—JAM FLASHING <br />WINDOW FLANGE <br />WRAP <br />SILL FLASHIING <br />SHEATHING <br />WINDOW FLASHING METHOD 'A-1- <br />A INSTALL JAMB FLASHING OVER THE WINDOW FLANGE ON EACH SIDE. <br />B. EXTEND THE JAMB FLASHING 4' A13OVE THE ROUGH OPENING AND 8' BELOW THE ROUGH OPENING. <br />C. INSTALL THE WINDOW ACCORDING TO THE MANUFACTURERS SPECIFICATIONS. <br />HOUSE <br />WRAP <br />/WOUSE <br />WRAP <br />'FLAP' <br />- ------------------------------- <br />EAD FLASHING <br />\_5ILL FLASHING <br />WINDOW FL44GE <br />/,--JAM FLASHING <br />WINDOW FLASHING METHOD 'A -I' <br />A. ALLOW THE BUILDING PAPER r-LAP'TO DRAPE OVER THE HEAD FLASHING. <br />ZWOUSE <br />WRAP <br />r-LAP' <br />---- ---------------------------- <br />WEATHER RESISTANT EAD FLASHIW-i <br />CONSTRUCTION TAPE <br />JAM FLASHING <br />HOUSE L <br />WRAP \—SILL FLASHING <br />SHEATHING WINDOW FLANGE <br />WINDOW FLASHING METHOD 'A -I' <br />A. APPLY WEATHER RESISTANT TAPE OVER THE 45. ANGLE CUT ON THE BUILDING PAPER, <br />5. ON INSIDE PERIMETER OF WINDOW APPLY CONTINUOU5 BEAD OF SEALANT OR EXPANDA13LE FOAM <br />.................. <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineenng.com <br />CA 25948 <br />CD <br />C:) <br />z <br />V) <br />z <br />� _: 'COD g). <br />Ln <br />mi <br />z <br />CL <br />00 <br />t� 9 <br />w <br />z <br />Z uj <br />Lu <br />Q <br />a <br />t.0 <br />IL <br />x <br />Lu <br />w <br />Lij CL <br />C:) <br />EL <br />Q <br />Lu <br />V) _j <br />z Q <br />< 9 <br />0 <br />P- < <br />C) <br />Z Lu V) <br />< z <br />z011 <br />00 <br />0 <br />LO <br />U CY) <br />n <br />V) <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = ±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />02019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />@2019 - THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, ULC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBI[TED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />STAIR STRAP <br />— <br />01.09.19 <br />—AND — <br />1.02 ROOF UNDERLAYMENT REV. <br />02.11.19 <br />1.03 UPDATED CONNECTION <br />I CROSS-REFERENCE TABLE <br />I <br />— <br />V E IRS I �N Q.1 5 �L QQ /,Q2.11.19 <br />0 <br />LJ <br />21, <br />C14 <br />d <br />Lu <br />00 V <br />i <br />z 0 <br />ILI <br />z <br />Lu 0 <br />R <br />L40 <br />t —<I F4 <br />�! <br />Im C14 /) 't <br />__J 'It 0 >- -0 <br />uj Lu (f) 'a :2 <br />*01) <br />Lu :::) * * L1.J <br />z 12i uj w <br />F3 V<) ['L� <br />z <br />Lu E1 El <br />SHEET TITLE: <br />WINDOW FLASHING <br />DETAILS & NOTES <br />SHEET INFORMATION: <br />JOB NO.: 390221 <br />DATE ISSUED: 02.20.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />WF-1 <br />LO <br />a <br />I <br />CNI <br />co <br />CN <br />LO <br />r__ <br />
The URL can be used to link to this page
Your browser does not support the video tag.