My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35965 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35965 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:15:37 PM
Creation date
2/19/2025 10:47:22 AM
Metadata
Fields
Template:
Building Plans
Street #
35965
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20740
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI1UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />F� <br />DUPLEX OUTLET ABOVE COUNTER <br />FETw P. <br />WEATHERPROOF DUPLEX OUTLET <br />K)G. F. 1. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />01 <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />LO <br />220 VOLT OUTLET <br />to <br />WALL SWITCH <br />�2 <br />C'4 <br />co <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />T3 <br />�R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />):�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />LO <br />C) <br />@) <br />RECESSED LIGHT FIXTURE <br />C*4 <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />19T;r <br />TRACK LIGHT <br />0 <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />V) <br />EXHAUST FAN/LIGHT COMBINATION <br />C-) <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[C H] <br />CHIMES (OPTIONAL) <br />C) <br />kEg <br />PUSH BUTTON SWITCH (OPTIONAL) <br />CL <br />E <br />PUSH BUTTON SWITCH - DOOR BELL <br />E <br />SMOKE DETECTOR <br />0 <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />co <br />-2 <br />LZ <br />FT <br />2 <br />TELEVISION (OPTIONAL) <br />E2 <br />FT�2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />C-3 <br />THERMOSTAT <br />ELECTRIC METER <br />0- <br />I <br />NMI <br />ELECTRIC PANEL <br />C1. <br />DISCONNECT SWITCH <br />�2 <br />1<:>% <br />SPEAKER (OPTIONAL) <br />F4 <br />04 <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />Q) <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />NEMA 1 <br />200 AMP <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />IDIsconnectl <br />POWERCO.FEED--- IT-'W <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14,250.94 <br />#14 copper to lights & outtets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />0 In <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />ENTRY LIGHT — <br />AS PER SPECS <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />(D <br />Anxi <br />�:: <br />I <br />2- C-) <br />C) <br />C> <br />C.0 <br />04 <br />I <br /><C <br />___j <br />MID <br />U)V1 2-1 <br />0 <br />0 <br />(1) C-/D- <br />LU <br />C) <br />0 U-1 <br />V) <br />E <br />0 <br />�3 Cl) <br />p <br />04 <br />'__ E <br />op Ce> <br />M ce, <br />C: ce) <br />D <br />aim <br />T C" <br />0 0 'S' <br />c) <br />00 <br />0 Co <br />C) <br />U, - 'X <br />ch < 6 <br />Al I <br />BID. <br />c"" c <br />C" F, <br />C' <br />Z Uj cj <br />U) op <br />LU <br />4) L:L <br />LU Z5 <br />in <br />Z 0 0 <br />0) <br />A <br />LL'Fa 0 i_ <br />Z <br />Uj <br />C-3 <br />U U <br />WWW.FDSENG.COM <br />C=) <br />C14 <br />C14 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineei's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 Z <br />0 <br />Z <br />Z <br />< <br />< <br />Z <br />r�80 <br />0 0 <br />U <br />unui <br />_j <br />2 'Z '� <br />0, <br />< <br />�2 <br />u_ 0 <br />04 <br />< <br />8 LU <br />Z Z <br />'ZI <br />0 <br />C) <br />_0 <br />Uj <br />CZL <br />Z <br />_j <br />4?: <br />Lu <br />0 <br />0 <br />Z <br />< <br />U <br />r1e) <br />0 <br />__j <br />00Z <br />.�_o <br />1:u- P <br />U_ <br />'- 6 <br />Q � <br />Z <br />co <br />0. 8: <br />EWo< <br />2z� j_ <br />= Z< <br />(D < <br />W <br />Z <br />8< @ * . <br />Z <br />2 8- OU <br />CY <br />LU <br />0- <br />g ZE <br />LU <br />8.1<4 < <br />1�0 <br />< <br />W Z <br />tu <br /><<O <br />CY <br />0 <br />00 <br />Z <br />:5 <br />LU <br />X: <br />V) 0 <br />� 7) <br />� F <br />< 2: <br />r7l <br />a. <br />U0 <br />�5 <br />SCALE AS NOTED <br />DATE 10/2/2018 <br />TECH: MIAMES <br />VERSION No' 42 <br />SHEEr NO. <br />4.1 <br />----------- <br />, 'i'lll 1, I__F__ IT- 11 1 111 R F _j 111. 11111 1. 1 .1. 1 � T. i I AIV <br />