My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35976 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35976 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:22:51 PM
Creation date
2/19/2025 10:47:46 AM
Metadata
Fields
Template:
Building Plans
Street #
35976
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20617
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LO <br />LO <br />M <br />4 <br />P1 <br />-8 <br />LO <br />00 <br />�R <br />Cf- <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44"AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2"AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at42"centerline above finished floor. <br />4. Electrical plan is intended forbid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance With FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoketcarbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or Window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />):�LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />Iwo <br />EXHAUST FAN/ILIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCH� <br />CHIMES (OPTIONAL) <br />[Eg <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br /><1 <br />9\> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />ME <br />TER <br />n <br />200 amp <br />150 amp <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER A <br />Q <br />NEC 14, 250.94 -/ <br />Copper to lights & outlets <br />copper to 20 amp cids <br />-2 copperto WH <br />.3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />L <br />ENTRY LIGHT — <br />AS PER SPECS <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=l'-O" <br />ova <br />2- M <br />13 <br />U) <br />a <br />Qj C—/> <br />4--J LU <br />U <br />0 LLJ <br />rU <br />CC3 <br />C4 <br />C-" <br />U. <br />Go <br />to <br />< <br />U., <br />Ci <br />A I <br />N-C-S-D-C <br />C4 `0 <br />U Z <br />LU <br />LU <br />rwk <br />Z 0 <br />1JL Z <br />LU <br />WWWLFDSENGCOM Li U <br />co <br />[To <br />the beat of the Engineer's knowledge, information'and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florrida Building Code - <br />Residential 6th Edition. Engineses signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />UJ <br />00': <br />< <br />0 <br />C—) <br />Z <br />`0 <br />%%..00 <br />Lij <br />__j <br />LJJ <br />> <br />0 <br />U*) <br />0 <br />LL <br />I"- P <br />196 <br />Jill <br />8 �t <br />C4 <br />< <br />Z <br />Ln <br />r*4 <br />Z <br />LLI <br />_j <br />Ln <br />V-1 <br />Lli <br />Z <br />LU <br />Z <br />t- <br />lZ ky <br />0 <br />Lr) <br />06 <br />Z <br />U <br />rn <br />I r_1 <br />IQ. <br />I CA 1 <br />5 <br />SCALE AS NOTED <br />DATE 4/13/2018 <br />TECH: JMUROSIC <br />VERSION NO - 4ol <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.