My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36029 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36029 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:25:36 PM
Creation date
2/19/2025 10:48:00 AM
Metadata
Fields
Template:
Building Plans
Street #
36029
Location
Stable Wilk Ave
Contractor
Lennar Homes LLC
Building Plans - Permit #
18704
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOP THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />I . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44"AFF <br />bathroom 39"AFF <br />laundry room 36"AFF <br />exterior waterproof 12"AFF <br />garage general purpose 42"AFF <br />range 2"AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42* centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict a=.rdance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with LL 217. <br />6. Provide AFCI's (Arc-Fauft Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or U1_ 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R3115.1.2 Combination AJaffns: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical pcwer source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped With an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBAk at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible waming <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' If the outside edge of a sink. This would include the receptacle Installei for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a rango or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range Is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />I ELECTRICAL KEY I <br />I Zn!k <br />PE�_" <br />DUPLEX CONVENIENCE OUTLET <br />lzl�,_ <br />FTF <br />DUPLEX OUTLET ABOVE COUNTER <br />OW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />I O=N <br />rl=;,-G . F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />1-4:4- <br />rw- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />_$4 <br />FOUR-WAY SWITCH <br />61 <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />MD <br />Qi_� <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FC_Hj <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60- A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br /></ 1> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /><1 \> <br />OPT. CEILING FAN <br />(n <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />'"S '' F', 10"&CLAIM <br />2D --1 #12wpper1o20ampdda <br />OAMP <br />910.2coppwbDWH <br />#1043 copper to Dryw <br />MAIN <br />-4, <br />0 <br />or 410 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />—A <br />cu <br />K�_4 <br />INTERSYSTEM <br />Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />Y <br />WITH CODE APPROVED <br />NEC K 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />RUILDFR <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />0 <br />Z <br />Z co <br />V) (D <br />Z <br />Q) C—/) <br />+_j W <br />U <br />0 Lj-j <br />V) <br />0 <br />000 <br />C) <br />:6 LL Co <br />.5 <br />00) <br />05 Q-01 <br />0 -V <br />Do <br />N-C-S-D-C <br />tZ4- <br />IN- Cq __j <br />cs &I <br />Z <br />ZVE;4�; <br />Z0 <br />mr4w 2 CP F, <br />uj <br />a <br />v <br />ja #j g.r_ U. 0 <br />r <br />CL Lu <br />Z <br />4 <br />0 <br />.9C.9 <br />-.6 <br />Z <br />LL Cli <br />ix <br />In ca <br />in <br />W <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seat. <br />C) <br />,Z, <br />Z r%j <br />0 cu <br />1-4 :L-0 <br />U') :3 <br />> V) <br />0-4 <br />re) <br />M Ln <br />in <br />Z <br />CL <br />in <br />(1) —0 Ln <br />L_ U_ e-N <br />QL <br />Z < CL 00 <br />Z E <br />M <br />LZ F- <br />Li C:) <br />W <br />F- <br />5480, <br />Ce <br />< <br />Lu <br />F_ <br />Z <br />8 <br />Ln <br />C-) <br />Z <br />-.0 <br />N <br />LJLJ <br />_j <br />M <br />Lr) <br />LLI <br />0 <br />> <br />r*4 <br />I= <br />0 <br />Lu <br />Q <br />iz <br />0 <br />U- <br />Zo <br />ng <br />F- <br />Z <br />< <br />Uj ce <br />Z <br />Z <br />LLJ <br />-j <br />Ln <br />LI; <br />19ZE <br />H� <br />Cn <br />%D <br />Z <br />< <br />Z <br />I �'- 8 <br />t2 Z <br />Z <br />Z <br />0 <br />r�l <br />:5 <br />Uj <br />2 <br />ffi <br />rn <br />T-1 <br />0- <br />Z <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: ERAND <br />VERSION NO - 10 <br />SHEET NO. <br />4.0 <br />