My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36071 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36071 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:27:46 PM
Creation date
2/19/2025 10:48:25 AM
Metadata
Fields
Template:
Building Plans
Street #
36071
Location
Carriage Pine Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
18534
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />�@W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />kz=_ <br />r'ZV-G . F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I /-\ <br />pi -IF <br />HALF -SWITCHED DUPLEX OUTLET <br />L.,�;Ih <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08,250.94 —/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />opper to lights & outlets <br />opper to 20 amp clas <br />copper to WH <br />copper to Dryer <br />t Alu <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />EXHAUSTFAN <br />GFI <br />F1 <br />___Wj <br />F _IM�4114 <br />APFI:11 <br />1 Ak <br />11 <br />F-1 <br />I tLLU I HIUAL FANtL <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />DEDICATED RECEPTACLE <br />VERIFY METER <br />FOR MICROWAVE RANGE <br />ICH <br />CHIMES (OPTIONAL) <br />HOOD PER SPECS <br />LOCATION WITH <br />BUILDER <br />11 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />@ <br />SMOKE DETECTOR <br />SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />W 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />__M1=L <br />DISCONNECT SWITCH <br />llc�% <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: )/4"=1'-0" <br />0 <br />Z <br />Z <br />Z <br />Z <br />V) (D <br />Q) C-111) <br />u, <br />0 LLJ <br />L104) 1(2� <br />D U <br />E <br />0 <br />2 <br />V) <br />M <br />.2 8 <br />4) cn <br />E <br />8 <br />C" (1) <br />C M Cl) <br />�MS 0 <br />000 <br />- <br />= LL 00 <br />= - 00 <br />0 M <br />< 00) <br />CD <br />D,j <br />C,4 <br />to <br />.00, <br />04 Z <br />Z <br />cS <br />Z <br />r, <br />c—.3 <br />WIN 04.)! 2 T rZ 4M. <br />ILL ILL <br />in <br />J, <br />LU LLI <br />a- CL <br />2� <br />0 <br />'M It` <br />Zco <br />LL <br />X co <br />IM <br />cm <br />X < M <br />_j <br />W UJI Pn <br />El 11 0 <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal Is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />Z <br />0 <br />> C� <br />V) p <br />M Ln <br />V) 0 <br />U_ <br />F- a> � <br />fo <br />ct� U a 00 <br />Z < <br />. E <br />Z3: <br />Z <br />LU C� <br />_j 0 <br />W 11.0 <br />lir <br />mi <br />Z,< <br />Z <br />Z <br />bZ80 <br />ce <br />U, <br />Z <br />0 <br />Ln <br />b <br />Z <br />-0 <br />(0 <br />N <br />Ln <br />LLJ <br />__j <br />Uj <br />> <br />0 <br />U <br />0 <br />0 <br />_j <br />U_ <br />0 <br />i:-U <br />agg <br />:Z <br />0 <br />CLY_ <br />< <br />Z <br />a uj be <br />Z <br />Uj <br />Ln <br />LU <br />Z <br />< <br />< <br />Z <br />LU;5 <br />r_j <br />Z <br />Z <br />0 <br />N <br />:5 <br />LU <br />rn <br />T-4 <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: FLORES <br />VERSION NO' 10 <br />SHEET NO. <br />4.0 <br />