Laserfiche WebLink
ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />13/4 x 11- <br />JVL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2X4 UNDER STRINGER GLUED AND <br />NAILED TO LANDING BLOCKING <br />D <br />2X4 PT NOTC <br />INTO STRINGER <br />L <br />I,---2X8 BLOCKING FOR STRAP <br />Z - I I I I - <br />M <br />_�IX4 bloCking <br />m I � I nAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD (USP <br />MTW12) <br />PLAN VIEW <br />SCALE.T"=V-5� <br />NOTE: <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />FOR RISE AND RUN INFORMATION. <br />3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN T' <br />AND �'GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x1 2 TREAD <br />GLUED AND <br />NAILED <br />2X4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE -AT <br />STRINGER CONTACT <br />POINTS <br />2X4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />'�-2x8 SYP DRYWALL STOP MUST <br />�/NOT TOUCH STRINGERS <br />2X4 BLOCK IN KNEEWALL FOR 2X12 NAILING <br />IX4 GLUED AND NAILED TO STRINGER <br />FOR DRYWALL SPACING <br />SECTION VIEW <br />SCALE: 1'-0" <br />SCAB 2x4 GLUED AND NAILED (EACH <br />2x12 SYP SIDE) TO BOTTOM EDGE OF 2x12 <br />ALIGN THIS STUD WITH 3/4" RISER CUT TO FIT STRINGER STRINGER <br />FACE OF 2ND RISER <br />MAINTAIN BETWEEN <br />A AND "' GAP TOP AND <br />I'll BOTTOM, GLUED AND <br />STRINGER MUST MAKE FUL NAILED TO STRINGER 2x4 BEHIND RISER <br />CONTACT WITH LAN DING 77c\ BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO <br />2x4 DRAFT RISER AND TREAD <br />2 <br />FLOOR STOP <br />JOIST x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />Nh <br />777777777/ <br />F/77777 <br />SYP <br />2X8 SYP <br />2x8 <br />SYP <br />PT NOTCHED INTO STRINGER - <br />D NAILED TO FLOOR WITH GLUE <br />STRINGER CONTACT POINTS <br />2x4 CUT <br />DOES NOT BEAR IN <br />WALL GLUED TO <br />2x8 <br />F <br />SECTION VIEW "All <br />SCALE: 1 V-0" <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />E <br />2X4 PT NOTCHED INTO STRINGER <br />< AND NAILED TO FLOOR WITH GLU <br />I I I <br />AT STRINGER CONTACT POINTS <br />DOES NOT B <br />2X4 CUT ON BEVEL - <br />EAR I N <br />WALL <br />SECTION VIEW "D <br />SCALE: 1 V-0" <br />FILLER STRIPS ADDED 'PLYWOOD <br />GLUED & SCREWED TO <br />4 <br />PLYWOOD DECKING <br />PC <br />X-2x SYP CUT TO FIT <br />BEARS IN WALL <br />___2xl2 SYP <br />B <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1 V-0" <br />NGER <br />3LUED <br />NAILED <br />SECTION D-D <br />SCALE: 1"= V-0" <br />-3/4 PLYWOOD <br />ON DECK <br />__2x8 SYP GLUED <br />AND NAILED TO <br />FRAMING <br />2X4 DRAFT 2x12 <br />STOP TREAD <br />GLUED <br />AND <br />2X4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE -AT <br />STRINGER CONTACT <br />POINTS <br />H <br />H <br />BLOCKINP FOR <br />SID <br />11 <br />10 <br />x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />GLUED AND NAILED TO STRINGER <br />OR DRYWALL SPACING <br />2x4 SYP BLOCKING <br />FOR STRAP <br />(USP MTW12) BEHIND <br />RISER <br />SECTION VIEW 111311 <br />SCALE: 1 V-0" <br />-ALIGN THIS STUD WITH FACE OF 2nd RISER <br />2X4 SYP <br />BLOCKING <br />STRAP(Uq <br />MTW12) <br />SECTION VIEW "Ell <br />SCALE: 1 V-0" <br />E SECTION VIEW <br />SCALE: F0,; <br />-3/4 PLYA <br />ON DECH <br />—2x8 SYF <br />AND N� <br />FRAMIIS <br />-2x4 DRAF" <br />STOP <br />2X4 BLOCP <br />BLOCKING FOR 2x12 <br />PT UNDER 2x12 C <br />ATTACH ALL COMPONENTS <br />I W/.'"x <br />OF STAIR TO CONC- 4 <br />2 T'TAPCONS @ MAX. 32" O.C. <br />- 1X4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP <br />-2x8 SYP DRYWALL STOP <br />MUSTNOTTOUCH <br />STRINGERS <br />L--2x4 BLOCKING FOR 2X12 <br />2x4 PT UNDER 2x12 <br />2X4 CUT ON <br />BEVEL GLUED - <br />AND NAILED TO <br />LVL <br />---PROVIDE MOISTURE <br />PROTECTION <br />ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/ T'X <br />2 t'TAPCONS @ MAX. 32" O.C. <br />_1x4 GLUED AND <br />NAILED TO STRINGER <br />11CIII <br />SECTION VIEW <br />SCALE: 1"= 11-01, <br />TOP OF <br />/-STRINGER <br />CONN. TO BOTTOM NEWEL POST LET INTO <br />OF NEWEL POST THE BLOCK <br />PER CONTRACTOR <br />PROVIDE <br />zz� BLOCKING <br />__-�2X8 BLOCKING <br />FOR NEWEL POST <br />TO ANCHOR TO. <br />I nr),; PROVIDE SOLID BLOCKING (GLUED AND NAILEDI <br />FLOOR GIRDER <br />BELOW ALL NEWEL POST <br />OR 1 x 16" VL FROM JOIST TO JOIST. USE <br />2 X 12 BLOCKS, GLUED AND FLOOR <br />NAILED TO JOIST. TRUSSES <br />NEWEL POST <br />SECTION VIEW "G <br />bL <br />ll <br />SCALE: 1 V-0" <br />OCKING <br />SCALE: 1 V-0" <br />0 1 /Alrx koUINO I MUk.# I IUIN UE I /AILO <br />(IF 1 1X1 7 REDUCE SCALE.5) SCALE: AS NOTED <br />JOINT <br />. TO <br />)ISTS) <br />NAILED AND <br />TOP PLATE <br />qTO RIM BAND, <br />ID NAILED TO <br />NALL BELOW <br />JOINT <br />-TO <br />)ISTS) <br />2X <br />USP <br />ECTION VIEW 111-Ill <br />SCALE: 1 V-0"' <br />< <br />__j <br />U) z <br />V) (D <br />Q) <br />U <br />0 U_j <br />�e <br />1- E <br />V) �_ <br />0 <br />W <br />'m <br />CD <br />LU <br />E <br />0 <br />N <br />(u co <br />0) CQ <br />C C', C', <br />2:2 M <br />0 <br />(D <br />ely a) <br />-r- E 00 <br />*5 j !� <br />0 <br />c T <br />-.e <br />U) CL 0 <br />LO 0 -,t <br />< 0 <br />CM <br />a 0. <br />< <br />A I <br />0 D. <br />N-C-B D-C <br />CO <br />r- <br />U) <br />z <br />z M Z� <br />:9 2 .�< <br />=Lj__ <br />` " <br />- C11 <br />W <br />W eb <br />I <br />J <br />�vj - a? <br />a- <br />9d <br />�Rt <br />— <br />z <br />2q-.9 <br />Ac). <br />E. <br />Z 01 2 <br />IL <br />�, �1.2 <br />12 lic; 7-2 <br />W <br />%"�j <br />V <br />IS, <br />To the bes <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C:) <br />0 <br />Z r'j <br />0 a) N <br />1­4 4-j C:) <br />U0 'S ;,0 <br />> U.) rt) C:) <br />C:) <br />f0 Lr) <br />< <br />z <br />L <br />a) Ln <br />L <br />0. LL <br />Q� U <br />z <br />0-00 <br />< %­00 <br />E <br />z <br />LU C) <br />_j C) <br />W t.0 <br />zz g <br />-< <br /><z O'� WL <br />8,0, <br />'. 0<� <br />UZ <br />=) z Z <br />a z <br />W� <br />0 10 <br />2 0 <br />@ <br />z <br />8 <br />Ln <br />C <br />n <br />z <br />z <br />0 <br />Uj <br />> <br />A <br />0 <br />U <br />ur) <br />5 <br />LU <br />8 <br />< <br />< <br />U, 5 <br />LL_ <br />P <br />0 <!Z< <br />-. g <br />< <br />u<1 �1: <br />z 0 <br />1 -0� <br />z <br />71 <br />=0, <br />W Zz. " <br />LU <br />_j <br />Lr) <br />?--I <br />1 1 <br />Llj <br />3 I<D <br />28Z8 <br />LLJ <br />< <br />0 Uj <br />t.0 <br />z <br />8 <br />z <br /><� <br />v--4 <br />z <br />Z <br />t <br />M <br />cy;� <br />V1 Z <br />0 <br />0 <br />LU <br />z <br />LU <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: MIAMES <br />VERSION NO 10 <br />SHEE­r NO. <br />ST <br />