36101 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36101 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:37:05 PM
Creation date
2/19/2025 10:49:07 AM
Metadata
Fields
Template:
Building Plans
Street #
36101
Location
Stable Wilk Ave
Contractor
Lennar Homes LLC
Building Plans - Permit #
18398
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />ELECTRICAL SPECIFICATION <br />NO -TES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />015 copper to lights & outlets <br />NEMA 1 <br />200 AMP #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN <br />0 <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Isconnect <br />POWER CO. FEED <br />_It <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />[;P <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC, <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />S. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFC1 protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />Within 6' if the outside edge of a sink. This would include the receptacle Installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />Lj=� . <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE5w.P. <br />WEATHERPROOF DUPLEX OUTLET <br />OG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />N�-- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />_�)4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />@) <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />W—W <br />EXHAUST FANILIGHT COMBINATION <br />mr) <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RCH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />1/\ 1> <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FC <br />L <br />L _j <br />UPPER ELECTRICAL PLAN <br />SCALE: )/4"=V-0" <br />(D <br />0 <br />CO <br />Q <br />V) (D <br />Q) <br />C—/) <br />4—J LU <br />0 LU <br />I <br />0 <br />Ce) <br />V) F___ <br />00 <br />Fn r- <br />U <br />04 <br />M <br />E <br />0) C0 <br />I= 04 <br />8 <br />oil <br />000 <br />M Qi <br />r- FL Co <br />ci!� <br />0) <br />-.e <br />CL 6 <br />Lo 0 't <br />< 0 <br />tm <br />q 0. <br />ch< <br />N C B-D-c <br />to M <br />C14 LO <br />zi; M <br />CN <br />L0 12 <br />00, 4;; <br />6 CS <br />Z Lo <br />C0 0 <br />0 C-4 04 <br />r- Z <br />;Z <br />W 41F 1— .9 2) T c <br />jL - 0 <br />.1 <br />. - <br />LU <br />C' <br />14 <br />Lu <br />L� <br />a_ <br />LL c, <br />< CL — Z <br />ot <br /><= <br />Z 0 <br />L. N <br />j5 In to 9 <br />M <br />Z 44 31 E I.- P <br />44 c, Is -1 8 <br />N <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />CD <br />C) <br />Z r-4 <br />0 (3) r-, <br />4-0 C=) <br />5 t�o <br />c) <br />> V) M <br />ro CD <br />U-) ro Lr) <br />Z '2'�: <br />< -0 <br />0- ul C: <br />(n 0 <br />a) — Lr) <br />L_ <br />< L.L <br />CL I re) <br />U CL <br />Z <br />< OC) <br />Z § E <br />Z <br />C) <br />WIJj <br />_j C:) <br />01 <br />Z <br />1 <br />EZ80 <br />0 <br />U, = <br />CL <br />ZZ Z< <br />�E.,Z <br />Q � U., <br />0Z <br />Lu <br />on <br />8 V,) <br />Z Z <br />8 <br />Lr) <br />c) <br />Z <br />Z <br />Z <br />LU <br />L2 <br />Lr) <br />_j <br />LU <br />0 <br />0 <br />U <br />U') <br />0 <br />LLJ <br />_j <br />LL. <br />0 Z <br />IU 0 <br />0 <br />U, 0 <br />U <br />C� E <br />< < <br /><Z <br />u, �: <br />2: 80 <br />mgce <br />IM <br />Z <br />0 <br />Z <br />Lu a u- <br />U-1 <br />_j <br />Ln <br />L]j <br />C) Z <br />g T, :,:) <br />0 Z <br />0 uJ <br />u_ 14 <br />< <br />01 <br />Z <br />i� <br />< uJ Z <br />Q� <br />re) <br />Z <br />ITJ <br />I <br />CY < <br />V) L0 <br />Z <br />M <br />Z <br />LU <br />�O <br /><M <br />Z <br />LU <br />SCALE AS NOTED <br />DATE 2/24/2014 <br />TECH: WAMES <br />VERSION NO - 10 <br />SHEET NO. <br />4.1 <br />f <br />. I . 1� I , � I I , . � -F-U7, FT-, f , i I I.. 1� � Al 4 1 . I I I I I I I I I <br />