My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36363 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36363 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:46:02 PM
Creation date
2/19/2025 10:49:27 AM
Metadata
Fields
Template:
Building Plans
Street #
36363
Location
Camp Fire Ter
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2, All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Are -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />tk:::;'-G F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />k�;= <br />HALF -SWITCHED DUPLEX OUTLET <br />L.r_'h <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />m?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />MQ <br />Llz�_ <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FC�H <br />CHIMES (OPTIONAL) <br />kE <br />PUSH BUTTON SWITCH (OPTIONAL) <br />ko <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />V� <br />TELEVISION (OPTIONAL) <br />FTV] 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />JIL. <br />r <br />LAV -r---. <br />I <br />3" VTR <br />JIL <br />OPT. <br />LAV <br />LAV I <br />PLUMBING RISER. <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />- <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />__T0_000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />1 <br />Power Co. Feed <br />NEM <br />3R <br />200A <br />Indoor Panel <br />Center <br />]N <br />P <br />I Cable <br />#4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT WP <br />GFI <br />I 11K <br />26 <br />DINING <br />KI TCHEN <br />F - - - <br />F <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />_1 <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT <br />< <br />FOYERI�. <br />DB <br />�13 <br />ENtRY WP 0— <br />LIG[ITAS (!�kGFI@ <br />PER SPECS <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />LU <br />LU <br />0 x <br />LU <br />LU 0 <br />> <br />00 <br />I <br />qF-L —.j <br />I <br />I UPSTAIRS L <br />GFI <br />@ 44" <br />�,W.H <br />A.F.F. <br />0 <br />]GARAGE <br />GARAGE <br />LIGHT AS <br />TER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r— — — <br />— — <br />— — — — — — — — — — — -- <br />�z Uj <br />P: < <br />X <br />< <br />0 <br />0 <br />LU <br />_j <br />> U.1 <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1.532. <br />SCALE: y4"= V-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />F_ <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />—7 <br />2ND ELECTRICAL - UNIT -A 1532_ <br />SCALE: A"= V-0" <br />CV11 <br />C_j <br />C= <br />LU <br />Q_ <br />LU <br />Zn <br />LL. <br />C' = <br />F4 <br />CC'.24 <br />2 W <br />CL W <br />r <br />CD <br />Z5 <br />co <br />13 <br />E <br />CD- <br />cv-> <br />cli <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition, Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />.4 <br />E <br />c:, Om 8 ED <br />0 N <br />CN a) <br />0 <br />L <br />N 0 a_ LU <br />M LL LL <br />- <br />U) Z <br />_j - 3: 0 <br />:� -': �; 0 <br />Z <br />I% <br />C) <br />6 = <br />LLJ <br />W <br />G M <br />0 M <br />W <br />Z <br />LL <br />(0 1 <br />-L o' 0 �.j <br />a <br />0 " < < 0 = <br />Z <br />N 0 U) <br />B Z <br />0 (5 El r-1 E] <br />W <br />< < <br />W V) <br />W <br />0 <br />'2 <br />(a) <br />. <br />4-J <br />LU <br />u <br />0 <br />Ul <br />LIJ <br />V) <br />170 <br />U) <br />C) 6 <br />E <br />C) 2 Z6 <br />U) <br />I <br />< 0 <br />cl_� <br />0 <br />Z< <br />U_ <br />c6 E <br />E <br />CU <br />C1 <br />'0 <br />00 <br />C8 E <br />co <br />0' <br />"0' <br />0 < <br />Z <br />ro <br />4B t <br /><1 . <br />.0 <br />Z <br />Z� <br />CJ3 <br />C <br />co <br />�0 <br />3: <br />0 <br />0 <br />'Z <br />3: <br />2 <br />W <br />M <br />< <br />'0 <br />00 <br />L) <br />co <br />CN <br />C-0 <br />LO <br />0_ <br />Cy- <br />E <br />0') <br />60 <br />W .2 <br />ca <br />L) <br />ML) <br />4_j <br />*-j <br />0 <br />LO <br />CY) <br />CO <br />LO <br />C; C\1 <br />C:) <br />C=:) <br />co 04 <br />(M <br />LO <br />N <br />(0 <br />coT_ <br />"rl— <br />E <br />'E <br />C10 <br />L0 <br />0 <br />;E <br />M <br />Z <br />:3 <br />E <br />CU <br />r_ <br />ca <br />E <br />0 0 <br />-0 cu <br />a) <br />0 _j <br />< 0 1 <br />_j <br />30B <br />NO: 23-05719-05724 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />--I _11--__TN <br />I - ' - I. �� � 11, 111[10� , �_l 11 11 Vdh_ �F 1__LU�1' � <br />