My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36445 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36445 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:52:12 PM
Creation date
2/19/2025 10:49:52 AM
Metadata
Fields
Template:
Building Plans
Street #
36445
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6594
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />4 <br />5 <br />4 <br />5 <br />4 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39" AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44"AFF <br />Range 2" AFF <br />2. AJI trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. AJI work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With LIL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in LIL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSULIL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6'of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />14:�' <br />r�� <br />DUPLEX CONVENIENCE OUTLET <br />I '-�' <br />P�fF <br />DUPLEX OUTLET ABOVE COUNTER <br />w. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />_?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />3::� <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />PCH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />4( <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />/7_"�� <br />& <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />0 #14 to lights& outlets <br />NEMA 1 11 #12 to appliances and GFI <br />150AMPI <br />200AMP 0 #10toWH <br />00 #8 to Range <br />10 #6 to HVAC <br />.-7RT <br />n m <br />200 amp <br />150 amp <br />UNDERGROUND ID1s <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17,250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/LITILITY COMPANY. <br />111— 1.5" VTR <br />< <br />14 <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FOR DISPOSAL <br />DEDICATED <br />RECEPTACL <br />FOR MICRO\ <br />RANGE HOC <br />PER SPECS <br />L <br />OPTIONAL LIGHTING <br />SCALE: Y4"=l'-O" <br />— — — — — — — — — -- <br />ROUGH-IN FOR <br />I I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />BEDROOM 2 <br />L- — — — — — — — — — - 4 <br />dhEP <br />L--------------------------------------- j <br />0 <br />AC PAD <br />WP <br />_10 GFI <br />Disc. <br />DINING <br />FAMILY <br />5'-8" <br />ROUGH -IN FO <br />R <br />OPT. CLG. FAIN) DEDICATED <br />LIGHT PRE -WIRE RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />1000, 0- <br />C') <br />KO?PEN I [---,�'ITOLI HTS I <br />I I IAND SWITCH I <br />TO ABV. I I I IABOVE <br />I I I 1 11 111 11 <br />FOYER GFI <br />�GF <br />@ 44" <br />A.F.F. <br />IDB <br />I <br />0 <br />14 4, <br />JENTRY LlGi�r <br />AS PER SYECS <br />T <br />PC <br />E E <br />--------------- <br />LANAI <br />\\Wl ROUGH -IN FOF4 <br />'L -r OPT. CLG. FA�/ <br />GHT PRE-Wf RE <br />IWP <br />1 GFI <br />0 L Im M <br />W T�' — '.- <br />PENDP.NT PER SPEC <br />GFII <br />3 <br />F1 <br />LG F <br />G I I <br />I <br />IL El I <br />ITCHEN <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />WD. <br />I ' <br />,G <br />W.H. <br />_j <br />Z LU <br />0Z <br />�g <br />(5 <br />0 <br />U. <br />Fr 0 <br />LU <br />LU _j <br />> LLJ <br />GARAGE DOOR <br />GFI <br />Ir ------------ GARAGE -------------- I <br />I I <br />I I <br />I I <br />M 9 IRRIGATION <br />GFI @ 44-1 <br />A.F.F.1 <br />-------------------- V 0 <br />------------------------------- <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />ELECTRICAL PLANS <br />SCALE: Y4"=l'-O" <br />0 <br />E <br />E <br />E <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />r===zi <br />Ilf <br />I I ALT <br />11 AC PAD <br />I I <br />I <br />L=====J <br />WP <br />GFI <br />Disc. <br />W — <br />P R. <br />W <br />2- <br />0 Cr <br />W <br />U_ � a <br />R L) <br />W 0 <br />> _5 <br />co <br />C=11, <br />CD <br />0-r- <br />6a =- 9-2 <br />Cc r_� C-A <br />-0 <br />U_ 0- <br />C-4 <br />W cm <br />cc <br />'j, <br />C"> <br />C=� <br />C-1> <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineedng portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />W <br />E 'an C'j <br />0 C14 8 <br />04 <br />0) <br />6 <br />5 <br />.0 <br />00 LL <br />Cn P� —0 LL ui <br />C\l C� o. 0. <br />_j LL. Z <br />0 <br />0 <br />:2 C� 0 <br />Z <br />W <br />Z <br />IL <br />IL <br />OD Lu <br />Z� 0 <br />L0 C4) Z <br />a <br />(14 < L) co <br />17� F- <br />0 2 V <br />(1)(0 <br />u_ <br />LLJ <br />0 <br />V) <br />LLJ <br />U) <br />C) <br />LU <br />E <br />ce� <br />Z� <br />E <br />Z <br /><� <br />0 <br />F— <br />E <br />Z 0 <br />U 0 <br />0 <br />�O <br />Cn <br />- <br />1� <br />0.1 <br />0 <br />"OH, <br />Z <br />8 <br />g <br />8 M <br />0 <br />U <br />IN <br />(A) <br />C3 <br />Z <br />M <br />Mj <br />Cn <br />M 0 <br />0 <br />0 <br />M <br />0 <br />co <br />LO <br />LO <br />W <br />LO <br />0 <br />C) <br />LO <br />c) <br />CY) <br />04 <br />Lf) <br />LO <br />LO CD <br />N41 Q <br />T_ <br />E <br />> <br />CY) CY) <br />W LO <br />0 <br />M <br />Z <br />o <br />E T_ <br />CL <br />E <br />0 0 <br />_j <br />cc <br />< <br />JOB <br />NO: <br />23-06105 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />