My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36446-36468 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36446-36468 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:58:57 PM
Creation date
2/19/2025 10:50:17 AM
Metadata
Fields
Template:
Building Plans
Street #
36456-36468
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
7504-7507
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DIFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12"AFF <br />Garage - general purpose 44"AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centedine above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />I zE DUPLEX OUTLET ABOVE COUNTER <br />PqT <br />K)W:.pl WEATHERPROOF DUPLEX OUTLET <br />1 4:� GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />r'Z:;'-G . F. 1. <br />[Q-- HALF -SWITCHED DUPLEX OUTLET <br />I ah SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ WALL SWITCH <br />$3 THREE-WAY SWITCH <br />14 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o WALL MOUNTED LIGHT FIXTURE <br />(§) RECESSED LIGHT FIXTURE <br />+P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />% WIP <br />o ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RCH CHIMES (OPTIONAL) <br />H9 PUSH BUTTON SWITCH (OPTIONAL) <br />�0 PUSH BUTTON SWITCH - DOOR BELL <br />@ SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />awn ELECTRIC PANEL <br />Mai DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR <br />OPT. <br />LAV LAV <br />v <br />IHANSON <br />BOX <br />BOX <br />3" <br />W/C <br />LAV -r--_ <br />SHOWER <br />'U TUB/ - <br />W/C SHOWER <br />STUDOR DBIL SINK <br />VENT L 0 "\ <br />1_ W71 DISP. <br />21, <br />LAV 3" <br />1 W/C <br />PLUMBING RISER. <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS- <br />LINIT-A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATffR_ AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />LOAD WATTS <br />0 <br />-OTHER <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st10KWat100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS -- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE I <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />�TEOR MA N <br />1 0_2 0 A P JT /—Serial Cable <br />3R <br />Power Co. Feed _--� 11 [ #4 Solid COPPER Ground <br />C.O. <br />Intersystem Bonding -7 <br />Termination Per Z. <br />NEC 17,250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />r I <br />L j <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />WP <br />I <br />GFI <br />Im <br />0 8GFI <br />P <br />I <br />I <br />nININr. I <br />KITCHEN <br />T-1 <br />FI 0 <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />194 <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT <br />FAN/LIGH*T <br />\01 <br />FOYER <.-- <br />DB <br />EN <br />P& <br />Y W 0 <br />L I GVT A S G F I <br />PER SPECS; <br />DB & GFI TO - / <br />----------- <br />BE ALIGNED <br />VERTICALLY <br />W <br />F- 3: <br />W <br />Z <br />0 IC4 <br />W <br />Ft d <br />W 0 <br />> <br />__j <br />qEL — _j <br />rA <br />.1 UPSTAIRS t <br />GFI <br />@ 44" LW..H. <br />A.F.F. 0 <br />GARAGE <br />GARAGE <br />LIGHT AS <br />TER SPECS <br />\-,,, GARAGE <br />=li�51DOOR <br />GFI <br />r ----------------- 1 <br />1 1 <br />1 <br />W <br />Z <br />LLi <br />j <br />> LLi <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532. <br />SCALE: A"=V-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />F_ <br />OWNERS <br />BEDROOM <br />/,>ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />IN11 <br />0. BATH <br />BATH 2 <br />'11;� �, 7 <br />WIC <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />---------- <br />/P <br />__w I C <br />V_ - <br />---------- <br />\LOFT <br />S.D <br />/,>ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />\BEDROOM 2 <br />L_ - . - - <br />— __1 <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: X"=V-0" <br />C3 <br />C2 <br />2C <br />C= M <br />CL a <br />E <br />CJ <br />> <br />E <br />Cc C) <br />C."I <br />cli <br />C> <br />P11 <br />L E <br />E <br />d IV&` <br />Cj <br />No <br />750- <br />C) - STATIE <br />OF <br />% <br />1-v <br />A L <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />M�1111 a <br />All W <br />E 5? <br />8 <br />04 <br />(0 <br />60 <br />LU <br />04 C, <br />LL tL <br />LL . <br />=C0 <br />Z <br />cd 0 <br />M 0 <br />= X 0 <br />'Fo 04 M <br />Z <br />LLILW <br />L0 Z <br />-C4 0 <br />Z <br />CD <br />a) <br />4-J <br />0 <br />V) <br />U <br />d <br />U_ <br />2i E <br />0 <br />E u <br />C, <br />8 E <br />0 <br />t <br />W Z <br />C <br />C <br />W <br />MO <br />ff <br />Z <br />Z <br />Cl> <br />A <br />0 <br />0 <br />L I <br />,-(6 <br />F_ <br />C�4 <br />C_� <br />CID 00 <br />C`4 <br />00 <br />LO <br />W <br />50 <br />co <br />00 <br />4_j <br />4-J <br />0 <br />CN <br />E <br />0 <br />C� <br />C:) <br />04 <br />Ln <br />C:> <br />01) <br />< <br />C) <br />Lc') <br />N <br />CD <br />E <br />M <br />0 <br />Z <br />r_ <br />M <br />E <br />E <br />0 <br />2 4i <br />'D - <br />M <br />CL <br />0 <br />M <br />:�o 0 <br />(D <br />_j <br />30B <br />NO: 23-13121-13124 <br />SCALE <br />AS NOTED <br />SHEEr NO. <br />