My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36537 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36537 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:17:55 PM
Creation date
2/19/2025 10:51:32 AM
Metadata
Fields
Template:
Building Plans
Street #
36537
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />i <br />AB or A.B. <br />Anchor Bolt <br />ABV or Abv. <br />Above <br />AC or A/C <br />Air -Conditioner <br />ADJorADJ. <br />Adjustable <br />AFF or A.F.F. <br />Above Finished Floor <br />AHU or A.H.U. <br />Air Handler Unit <br />ALTorALT. <br />Alternate <br />BC <br />Base Cabinet <br />BF <br />Bifold Door <br />BK SH or Bk Sh <br />BookShelf <br />BLK or BILK. <br />Block <br />BLW or BLW. <br />Below <br />BM or Bm. <br />Beam <br />BOT or Bot. <br />Bottom <br />BP or B.P. <br />Bypass (door) <br />BRG or BRG. <br />Bearing <br />C <br />Carpet <br />CAB <br />Cabinet <br />CIR or Cir. <br />Circle <br />CJ or C/J <br />Control Joint <br />CLG or Clg. <br />Ceiling <br />CMU <br />Concrete Masonry Unit <br />COFF or Coff. <br />Coffered or Tray Ceiling <br />COL or Col. <br />Column <br />COMM or Comm. <br />Community <br />COMP or Comp. <br />Compressor <br />CONNorCONN. <br />Connection <br />CONT or Cont. <br />Continuous <br />CSMT <br />Casement <br />CT or C.T. <br />Ceramic Tile <br />D or D. <br />Dryer <br />DB <br />Door Bell <br />DBL or Dbl. <br />Double <br />DCF <br />Decorative Cementitious Finish <br />DEC or Dec. <br />Decorative <br />DED or Ded. <br />Dedicated (outlet) <br />DIA or Dia. <br />Diameter <br />DISP or Disp. <br />Disposal <br />DIST or Dist. <br />Distance <br />DMF <br />Decorative Masonry Finish <br />DS or D.S. <br />Drawer Stack <br />DTL <br />Detail <br />DV or D.V. <br />Dryer Vent <br />DVP or D.V.P. <br />Diverter Valve (plumbing) <br />DW or D.W. <br />Dishwasher <br />EA or Ea. <br />Each <br />ELEC or Elec. <br />Electrical <br />ELEV or Elev. <br />Elevation <br />EQ <br />Equal <br />EW or E.W. <br />Each Way <br />EXP or Exp. <br />Expansion <br />EXT or Ext. <br />Exterior <br />FBC <br />Florida Building Code <br />FDN or Fdn. <br />Foundation <br />FFB <br />Finsh Floor Break <br />FG <br />Fiberglass (Shower Pan) <br />FIN <br />Finished <br />FIN FLR or FF or Fin. Flr. Finished Floor <br />ABBREVIATIONS <br />FIX or FXD <br />Fixed <br />FLR or Fir. <br />Floor <br />FLR SYS or Ar Sys <br />Floor System <br />FOM or F.O.M. <br />Face Of Masonry <br />FP or F.P. <br />Fireplace <br />FIR DR <br />French Door <br />FRT <br />Front <br />FT or Ft. <br />Foot/ Feet <br />FTG or Ftg. <br />Footing <br />FXD GL <br />Fixed Glass <br />GALV or Galy. <br />Galvanized <br />GC or G.C. <br />General Contractor <br />GFI or G.F.I. <br />Ground Fault Interrupter <br />GT or G.T. <br />Girder Truss <br />GYP BD or Gyp.. Bd. <br />Gypsum Board <br />HB <br />Hose Bibb <br />HC <br />Hollow Core <br />HDR or Hdr. <br />Header <br />HGT or Hgt. <br />Height <br />HH or H.H. <br />Hand Held (plumbing faucet) <br />HORIZ <br />Horizontal <br />HS <br />Hard Surface (flooring) <br />ILO <br />In Lieu Of <br />INSUL or Insul. <br />Insulation <br />INT or Int. <br />Interior <br />K/WALL or K/Wall <br />Kneewall <br />KS or K.S. <br />Knee Space <br />LAUN or Laun. <br />Laundry <br />LAV or Lay. <br />Lavatory <br />LF or L.F. <br />Linear Ft. <br />LL <br />Lintel Length <br />LT <br />Laundry Tub <br />MAS or Mas. <br />Masonry <br />MAX or Max <br />Maximum <br />MC <br />Medicine Cabinet <br />MFR or Mfr. <br />Manufacturer <br />MGT <br />Management (room) <br />MIN or Min <br />Minimum <br />MIR or Mir. <br />Mirror <br />ML or M.L. <br />Microlam <br />MONO or Mono <br />Monolithic <br />MW or MICRO or Micro. <br />Microwave <br />NTS or N.T.S. <br />Not to Scale <br />OE or O.E. <br />Owner's Entry <br />OPNG or Opn'g. <br />Opening <br />OPT or Opt. <br />Optional <br />PC <br />Pull Chain <br />PED or Ped. <br />Pedestal <br />PH <br />Phone <br />PKT or Pkt. <br />Pocket (Door) <br />PL or P.L. <br />Parallam <br />PLF <br />Pounds per linear foot <br />PLNT SHLF or Pit. Sh. <br />Plant Shelf <br />PLT HT or Pit. Ht. <br />Plate Height <br />PSF <br />Pounds per square foot <br />PT or P.T. <br />Pressure Treated <br />PW or P.W. <br />Pre -wire <br />PWDR or Pwd. <br />Powder Room <br />RA or R/A or R.A. <br />Return Air <br />RAID or Rad. <br />Radius <br />RAG or Rag. <br />Return Air Grill <br />REC or Rec. <br />Recessed <br />RECEPT <br />Receptacle <br />REF or Ref. <br />Refrigerator <br />REINF <br />Reinforcing <br />REQD or Req'd. <br />Required <br />RM or Rm. <br />Room <br />RND or Rnd. <br />Round <br />RO or R.O. <br />Rough Opening <br />IRS, R/S, R/SH or R&S <br />Rod and Shelf <br />Sc <br />Solid Core <br />SD or SD. <br />Smoke Detector <br />SGD <br />Sliding Glass Door <br />SHorSh. <br />Shelves <br />SHT <br />Sheet <br />SHWR or Shwr. <br />Shower <br />SL or S.L. <br />Side Lights <br />SPECS or SPECS. <br />Specifications <br />SPF or S.P.F. <br />Spruce Pine Fir <br />SO FT or SF or S.F. <br />Square Foot (feet) <br />SO or Sq. <br />Square <br />STO <br />Storage <br />SW or S.W. <br />Shear Wall <br />SYP or S.Y.P. <br />Southern Yellow Pine <br />TB <br />Towel Bar <br />TEMP or Temp. <br />Tempered <br />THIKN or Thik'n. <br />Thicken <br />TOB or T.O.B. <br />Top of Block <br />TOM or T.O.M. <br />Top of Masonry <br />TOP or T.O.P. <br />Top of Plate <br />TP <br />Toilet Paper Holder <br />TR <br />Towel Ring <br />TRANS WOW or Trans. <br />Transom Window <br />TYP or Typ. <br />Typical <br />UC or u.c. <br />Under Counter <br />UCL <br />Under Cabinet Lighting <br />LINO or U.N.O. <br />Unless Noted Otherwise <br />V or v. <br />Valve (shower or tub/shower) <br />VB <br />Vanity Base <br />VERTorVert. <br />Vertical <br />VL orV.L. <br />Versalam <br />VTR or VTE <br />Vent through Roof / Exterior <br />W or w <br />Washer <br />WI or w/ <br />With <br />WA or W.A. <br />Wedge Anchor <br />WC or W/C or W.C. <br />Water Closet (toilet) <br />WD or Wd <br />Wood <br />WDWHDRorWDW.HDR, <br />Window Header <br />WH or W.H. <br />Water Heater <br />WIC or W.I.C. <br />Walk-in Closet <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />WP <br />Water Proof(ing) <br />WS <br />Water Softener <br />WWF <br />Welded Wire Fabric (Mesh) <br />PLAN REVISIONS <br />DATE VERSION DESCRIPTION <br />04/25/12 1.00 NEW BASE PLAN <br />06/25/12 2.00 GRADE BEAM FOUNDATION <br />08/26/15 3.00 2015 NEW CODE UPDATE <br />REV. 06.23.22 <br />03/06/18 4.00 FBC 2017 CODE UPDATES & MODEL UPDATES <br />05/30/19 4.01 MOVE KITCHEN DOWN, ADD 6" WALL AT REF. <br />12/19/20 5.00 FBC 2020 CODE UPDATE <br />F41 41-16: 11 Z <br />S ICI <br />1525 <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance. <br />m <br />c* <br />0 <br />cv <br />C� <br />cLLa. <br />41 dLJ <br />C <br />Q� C <br />e . , CD 3 a <br />w _�.��� <br />CZ i �aC a <br />C1 <br />C l7 <br />N <br />E <br />r� .� fl <br />W N a " <br />co <br />U zco <br />W-� <br />a �BFE4ta2 <br />a' <br />\ ` � <br />40 <br />`, <br />-��: <br />�� <br />e° rya <br />•�"• <br />Y F� <br />19-1 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H <br />W E <br />0 <br />QCDo <br />0 c N <br />N U:3) <br />� LL <br />QN MN V <br />LL LL Lll <br />J <br />c � cn <br />103 Z -W —a a Y <br />W o ` CO o <br />Z n N Z ¢ J <br />LLco CP <br />0 <br />I IL <br />In N <br />Z U O U o <br />Co <br />W El <br />(D � `n <br />z N M <br />o <br />Z N <br />ML <br />M <br />; z <br />W � a <br />4—J LL <br />W W <br />WU L„ g <br />c w <br />V)co <br />uaa <br />U <br />J <br />F— <br />oil <br />r <br />U o Y <br />� U) <br />Q p 0 <br />N J <br />ts <br />.4 <br />o <br />w <br />J <br />o <br />Q <br />c, <br />w� <br />Z o <br />� <br />o� <br />z® <br />MW <br />E <br />x�o <br />Z <br />a � <br />L <br /><o <br />ww <br />co <br />¢ p <br />z <br />aoZ <br />W 0 <br />m <br />Z <br />J <br />v 3 <br />F <br />0< <br />2z <br />go <br />W <br />A <br />oLLLL <br />w <br />a <br />v w <br />� <br />0LL <br />wF <br />r7 � <br />M <br />V <br />ao <br />ZIo� <br />6 <br />U � <br />=o <br />0 <br />= <br />J <br />> Lo <br />0 <br />rn <br />C7 <br />M <br />co <br />:3 L <br />CT co <br />V J o> <br />CN <br />m — <br />LO <br />LO <br />0 <br />CV <br />'� N <br />LO <br />n O <br />LO <br />f <br />V) N <br />T <br />LO <br />a, <br />M T <br />M LO <br />o <br />Z <br />Z <br />E N y <br />CU <br />IL <br />E <br />U Q 0 <br />JOB <br />NO : 23-06125 <br />SCALE : AS NOTED <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.