r <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />NEMA 1 Do #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 t0 WH <br />10 #8 to Range <br />10 #6 to HVAC <br />MAIN <br />W <br />O <br />150=2l 0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />BY POWER CO. <br />INTERSYSTEM4 <br />TDisconneSERVICE <br />Bare Cu Ground <br />BONDING4GROUNDINGWIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G. F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />16 <br />EXHAUSTFAN <br />111611EXHAUST <br />FAN/LIGHT COMBINATION <br />nD <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PI3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />f a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />11 <br />II <br />II <br />II <br />11 <br />===J <br />1.5" VTR ,III <br />I� <br />I <br />I <br />I <br />I r. <br />I I I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR DI <br />o I <br />GFI <br />2X4FL. / <br />I <br />KITCHEN <br />IGFI <br />I <br />I <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />IGFI RANGE HOOD <br />PER SPECS <br />37I 1 <br />01 <br />II <br />II <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET— <br />r====-, <br />II 111 <br />I I ALT I I <br />AC PAD I <br />Il JI <br />WP <br />GFI 4 <br />DISC. <br />WZ <br />O LU <br />>_1m <br />0 <br />r <br />PER SPECS <br />ELECTRICAL PLANS <br />SCALE: %4'=1'-0" <br />N <br />z <br />c <br />CD <br />m m <br />WA <br />o t <br />�s r <br />co <br />8 <br />G <br />sr- <br />sa ..t.� . <br />2 <br />CO W U <br />Ca <br />c E <br />,y <br />M <br />O <br />CV <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing <br />pages bearing <br />Engineer's signature and seal. <br />W <br />v Ep <br />QO co U <br />00 <br />N n <br />V N 6 C: <br />Q a) <br />x* u <br />a <br />• <br />J LL <br />U) z <br />� <br />V <br />�Q/ 00 <br />� <br />0 <br />O S <br />(1' S <br />x. 4' W ink rn <br />Z Z <br />LLw <br />¢ r- z <br />O <br />N to <br />U I=— <br />Z OU <br />❑❑❑ <br />W <br />o g <br />N <br />� o <br />J <br />M <br />U)L/)Z <br />(D o <br />LL <br />A <br />LdJ M. <br />O LU oUtft <br />V) <br />c!1 � <br />f6 <br />C) C <br />=e EdJ <br />E <br />- 6 O <br />ml <br />U o N <br />N � <br />o <br />JZ <br />w <br />M <br />J <br />03 <br />z <br />a <br />`2 <br />U_ <br />EI <br />Za <br />>ro <br />Zo <br />a 0 <br />E U <br />wO <br />z <br />Z® <br />ad <br />ram— rod <br />CL <br />oa <br />�o <br />t,< <br />"':' E <br />to <br />ao <br />a <br />�z <br />w Z <br />d7 <br />Z <br />0 , <br />�Z <br />M <br />a <br />¢z <br />a <br />2U <br />m0 <br />0 <br />Ott <br />Z <br />m <br />�m <br />¢� <br /><w <br />� Z <br />C <br />o= <br />OLL <br />z <br />go <br />W <br />T ? <br />11 <br />=r <br />� O <br />1, <br />H — <br />wz <br />S� <br />d <br />Z< <br />0 <br />Oi <br />>6 <br />Orn <br />E <br />m <br />co <br />co <br />Ln <br />U') <br />Q <br />Cr t- <br />�- <br />m _ <br />Ln <br />± + _ <br />LO <br />0 <br />CD <br />N <br />N <br />N <br />Ln <br />� <br />r <br />r <br />CY) co0 <br />3 MLOZ <br />Z <br />E N :v <br />to <br />m <br />d <br />7 °? <br />M <br />U Q 0 <br />C <br />CID <br />JOB <br />NO : 23-06125 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />