Laserfiche WebLink
/ <br />/ <br />/ <br />/ z <br />/ MINIMUM <br />HEADROOM <br />Q OR (2) <br />u SLOPED PLANE <br />w ADJOINING <br />n TREAD N051NG <br />(U � <br />FROM FLOOR a / <br />SURFACE OF / <br />LANDING / <br />FOR 61: 1 INCH = 25A mm, 1 FOOT = 304.8 mm. <br />MINIMUt-1 HEAD I�f <br />FOR 51: 1 INCH = 25.4 mm, <br />CONVENT I ON,4L e7,41 fRuJ,4' ' <br />EAC✓a FLIGHT <br />REGULATED ON ITS OUN <br />DIFFERENCE BETWEEN <br />GREATEST AND SMALLEST <br />ID <br />TREAD DEPTH WITHIN A <br />In P==1 <br />FLIGHT OF STAIRS 15 <br />LIMITED TO 3/8 <br />DIFFERENCE BETWEEN HIGHE5T AND <br />LOWEST RISERS WITHIN A FLIGHT OF <br />STAIRS IS LIMITED TO 3/S'. <br />FOR 51; 1 INCH = 25.4 mm. <br />5T,41 fR TOLEFANCE& <br />41REAR UNIT ONLY, <br />REAR UNIT CONFIG. - ST. CROIX <br />SCALE:: 1/4" = 1'-0" <br />6'-1 1/' <br />L <br />9'-4 1/4' <br />1 <br />T/ <br />2x6 P.T. LEDGER <br />0 <br />2xb GONV. FRAMING 6 16' <br />0/C W/ U5P HU526 <br />/ <br />W/ I/4' 0 x 2 3/4' <br />n <br />HANGER AT EACH END / <br />TAPGONS a 16' 0/C <br />_ <br />g 3/4' / <br />/ <br />14 RI5ER5 9 1 1/2" EACH PLUS <br />/ <br />�. <br />1 R15ER 9 13/4" <br />/ <br />14 TREADS g 9.15° EACH <br />HALF WALL W/ Ix6 <br />WOOD CAP (5EE I <br />TOTAL HEIGHT = 9'-4 3/4' <br />STAIR PAGE FOR 1 <br />/ <br />2 RISERS + 1 TREAD <br />= <br />HANDRAIL INFO.) i <br />/ <br />GREATER THAN 24' S NOT TO EXCEED 25' <br />/ <br />(2)1 112' + 9 3/4' <br />= 24 3/4" <br />L4NDIN6 <br />NOT TO INCLUDE <br />I' N051NG, <br />STAIR DETAIL - 1370/1371 - ST. CROIX <br />SCALE: 1/4' = l'-O" REFER TO SHEET 'STAIR' FOR INFORMATION NOT 5HOIN <br />R-10 112' <br />3'-II 1/2' <br />B <br />1A <br />LANDING I <br />s <br />ti= <br />LIVING ROOM <br />uP <br />n <br />c <br />7 r <br />KNEE <br />I <br />N w <br />WALL <br />m <br />14'-2' <br />DRAIN PAN,--, <br />r <br />DRAIN TO <br />m <br />OUT SIDE OF <br />- <br />W.N. <br />51.0 FOR <br />I N <br />o? <br />c0 <br />= <br />LAY UT <br />1'-4- I'-V 2'-10' '-0' <br />10'-4" <br />PRES <br />URE <br />BELIE <br />- <br />O <br />A T.P. <br />-A <br />,4TN 1/2 5 <br />I <br />- <br />m <br />FOYER <br />T.B. - � <br />a <br />",+� <br />N <br /><r <br />Z o <br />TILE CF <br />T, = <br />I x 1-I1 a Z <br />� <br />12" x 12' <br />IK, o <br />n, <br />3'-10--8'-4 <br />1/2' <br />O.N.G. 1'-11 1/2 <br />1 4'-5 1/2'T-11 <br />1/2" <br />1/2 WALL o 39 1/2' <br />42" KNEE WALL <br />— — — — <br />W/ I" x 6" <br />W/COUNTER <br />�-1 <br />1 OPEN'G8 1 �? <br />s <br />= WOOD CAP <br />ABOVE a 42' A.F.F. <br />p <br />l FLAT NOR. l o <br />cD <br />16" WIDTH <br />N, I <br />L <br />N <br />COUNTER ABOVE. <br />I <br />`n <br />o <br />NZ II <br />Z <br />to c0 <br />O <br />(DD 0 <br />- <br />KITCHEN 1 u <br />I <br />12' x 12° <br />DINING ROOM <br />12'-21/2' <br />21' <br />1'-51/2" <br />SEE DETAIL A" _ <br />FOR REAR UNIT <br />1 <br />> <br />L <br />112 34 514 <br />Al <br />(2) 25 514 <br />3'-0'x3'-0' <br />CONC. PAD <br />b'-S° <br />10'-4' 4'-10' <br />21'-10' <br />Ir <br />1 st FLOOR PLAN - 1370/1371 - ST. CROIX <br />SCALE:: 1/4" = 1'-0" <br />5'-4' <br />I' 2' OPENING I'-6' 3'-0 112' <br />I II I <br />I II <br />I II <br />I II <br />I II <br />II <br />KITCITIEN <br />KITCHEN PASS-THRU - ST. CROIX <br />SCALE : I/4" = I'-m" <br />TO WATER <br />SERVICE <br />r <br />- - - - � - - <br />T.B. <br />s+s M. 54TH <br />CPT. TILE o m <br />30" <br />-2BASE VANITY . `V ° <br />aT�f <br />= M,45TER 51JITE M.c. / <br />�o <br />_ B <br />I <br />UB/SHOWER <br />TILE TO 71-0 A <br />m <br />A50VE TUB----, <br />T.P. <br />�o <br />5'-10 1/2' 3'-2' 3'-o 1/4' 5' 3 3/4" <br />6,4TH 0 <br />5 1/2' WALL �s+ 30' 5A50 <br />s VANITY <br />a <br />2-4x6-,5 <br />I BF m Q° <br />n I HANSEN+�D <br />I BOX IS) Q '� <br />DRYER x v M.G. b n <br />1' <br />I VENT <br />LOCATE IN.(5EE <br />NOTES 1n, OIELD 2I <br />tw- KNEE WALLILE <br />G T MIN21"X36" <br />R/S <br />=T <br />� R/5 <br />-------- Xx2 - - - - <br />1 A <br />5-0x6-8ry <br />_ <br />BF `., v <br />2-6x6-S 3-0x6-S <br />BF <br />r <br />8'-0" 3'-21/2' 3'-5' 3'-3 1/2' <br />a, <br />I <br />a <br />BEDROOM 3 BEDROOM 2 <br />I <br />25 SH HD. 25 5H HD. <br />HGT.6'-10" HGT 6'-10" <br />6' 3" *EGRESS 9' s' *EGRESS 5'-11" <br />21'-10' <br />2nd FLO��� PL�N-�1370/1371 - S�T.CROIX <br />2 <br />ALE SC <br />WASHER <br />LAV l <br />W \ 1/2" <br />TUB <br />LAV. <br />_ Tr+ <br />TUB <br />WC \� <br />H.W.H. <br />PLUMBING LEGEND <br />------------- = VENT LINE <br />= SANITARY WASTE LINE <br />= COLD WATER SUPPLY <br />—�--� = HOT WATER SUPPLY <br />NOTE: LICENSED PLUMBER TO VERIFY <br />AND HAS THE AUTHORITY TO <br />CHANGE A5 NEEDED. <br />KIT. <br />LAV <br />WC <br />� Lei <br />112" <br />DOMESTIC WATER SUPPLY <br />SCALE: N.T.5. <br />To <br />�4" VTR <br />J' <br />I <br />I <br />2" <br />2" <br />� I I <br />I i VASH <br />I � <br />211 <br />FL00R I=L,4N NOTFES <br />1. WALL DIMENSIONS ARE FROM OUTSIDE FACE <br />OF BLOCK WALL TO IN511DE FACE OF <br />INTERIOR WALL. <br />2. DETERMINE THE LOCATION OF PARTITIONS <br />NOT DIMENSIONED BY THEIR RELATION TO <br />COLUMN FACE OR CENTER WINDOW JAMB <br />OR OTHER SIMILAR FIXED ITEM. <br />I. EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW <br />THAT COMPLIES WITH EGRESS CODES, IF <br />THERE 15 NO ACCESS TO EXTERIOR <br />THROUGH A DOOR, THE WINDOW MUST HAVE <br />A MAXIMUM SILL HEIGHT OF 44" ABOVE <br />FINISH FLOOR LINE OF THAT PARTICULAR <br />ROOM <br />2. ALL INTERIOR ANGLED WALLS ARE AT 45• <br />U.N.O. <br />3. ISSUANCE OF PLANS FROM THIS DESIGNERS <br />OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY <br />ALL NOTES, DIMEN51ON5, AND ADHERENCE <br />TO APPLICABLE BUILDING CODES PRIOR TO <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, <br />D IMEN51ONS, OR ADHERENCE TO <br />APPLICABLE BUILDING CODES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE <br />DESIGNERS OFFICE FOR CORRECTION <br />BEFORE COMMENCEMENT OF ANY <br />CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT <br />RELATED TO THE CORRECTION OF ERRORS <br />THAT ARE MADE AFTER THE FINAL PLAN5 <br />HAVE BEEN COMPLETED SHALL BE SUBJECT <br />TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO <br />THESE PL,4N5 BY ANY OTHER PARTY OTHER <br />THAN THE DESIGNERS OFFICE, THE DESIGNER <br />SHALL NOT BE HELD RESPONSIBLE. <br />4. EACH DWELLING UNIT & GARAGE UNIT TO BE <br />EQUIPTED W/ PORTABLE FIRE EXTINGUISHER <br />IN ACCORDANCE W/ NFPAI0 <br />5. DRYER VENT NOTE: <br />INSTALL BOOSTER FAN IN THE ATTIC TO <br />ACCOMMODATE THE EXCE55 LENGTH OF <br />THE DRYER VENT TO COMPLY WITH <br />SECTION M1501.3 F.R.C. LOCATE 50 AS TO <br />BE ACCESSIBLE, <br />DIMEN51ON CONVENTION <br />OVERALL 8 EXTERIOR OPENING DIMENSION <br />FROM OUTSIDE OF BLOCK <br />OUTSIDE FACE OF <br />8" <br />NOMINAL BLOCK <br />3 1/2" FRAME WALL <br />U.N.O. <br />,4iRE,4 T,45UL,4TION <br />UNIT 5T. CROIX <br />let FLOOR LIVING 691 5F. <br />2nd FLOOR LIVING b80 SF. <br />TOTAL LIVING 1311 5F. <br />ENTRY 21 5F, <br />GARAGE 0 6F. <br />TOTAL. 50. FT, 1392 5F. <br />I . I <br />V I 2" <br />LAV <br />BUILDING <br />WALL <br />TO <br />SEWER <br />SYSTEM <br />I - <br />2" _i-,--2" I <br />! I KIT. <br />SANITARY WASTE RISER DIAGRAM <br />SCALE: K15. <br />I <br />I <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineering.com <br />M� <br />0 <br />Ln <br />w <br />z�0 <br />ojrn� <br />QQPAmCeM 00Z OI00ZJ <br />Q� nw <br />ZL <br />LIJ <br />W3~ <br />W <br />z <br />o <br />0 <br />�o <br />V) �--� <br />w U <br />0 U <br />ZI <br />i <br />O Z <br />0 <br />i <br />V) <br />V) <br />Z <br />Q U <br />V <br />W <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH'i <br />2007 FLORIDA RESIDENTIAL BUILDING CODE, <br />(INCLUDING 2009 SUPPLEMENT) SECTION <br />R301 FOR 120 MPH, 3 SEC. GUST, EXPOSURE <br />"C" ENCLOSED (INTERNAL PRESSURE <br />COEFFICIENT = ±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />2009 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LEN NAR CORPORATION. <br />2009-THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING, LLC AND THE <br />CUENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED._ <br />- - <br />REVISION: <br />DATE <br />DESCRIPTION <br />09-29-09 <br />1.00 2007 FBC UPDTATES <br />VERSION NO. 1.00 / 09.29.09 <br />CA 25948 <br />❑ SAMUEL A. GREENBERG, <br />P.E. #34245 <br />THUY H. HUYNH, <br />P.E. #60122 <br />❑ IRWIN J. BENSON, <br />P.E. #49758 <br />ANDREW D. HAROLD, <br />P.E. #66715 - <br />ENGINEER SEAL: <br />, x <br />l 1-6 --- - <br />SHEET TITLE: <br />INDIVIDUAL UNIT <br />1370/1371 -ST. CROIX <br />SHEET INFORMATION: <br />JOB NO.: 290941 <br />DATE ISSUED: 09.28.09 <br />DRAWN BY: DZ <br />REVIEWED BY: TH <br />1 A j <br />