My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38335 Springhead Ln
Zephyrhills
>
Building Department
>
Building Plans
>
38335 Springhead Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:19:22 PM
Creation date
2/19/2025 10:53:35 AM
Metadata
Fields
Template:
Building Plans
Street #
38335
Location
Springhead Ln
Contractor
D R Horton
Building Plans - Permit #
3554
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: AA010146-D199-4BBB-A59B-84ED05CCE60C <br />EXISTING EXTERIOR CMU <br />I <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/s' DIA. TAPCONS / o <br />OR CUT NAILS @ 24" O.C. COVER D <br />FLUSH w/ 3000psi CONCRETE. <br />EXISTING FOUNDATION. <br />D c <br />pl D <br />D \ \ a <br />D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDC <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVEI <br />FLUSH w/ 3000psi CONCRETE. <br />STING FOUNDATION <br />D <br />D <br />8" CMU WALL OVERHANGS 2.511 OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />_ 0' _0" A.F.F_. SEE ARCH <br />�- -a -° - - (MAX 20" <br />16° 4 ° a ° DEEP) <br />4" <br />4" EXTENSION <br />UNDER BRICK VENEER <br />F12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° \/\\ CV <br />4 ° d <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />L <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />c <br />N <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TOP OF FOOTING <br />TYPICAL STEP IN FOOTING DETAIL, <br />CMU STEMWALL MONO LITHIC SLAB <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />- - •I • a . • e , <a . #4 OR #5 <br />• < < . . e REINFORCING PER <br />° MONOLITHIC FOOTING <br />SECTION <br />`e ° . • FOOTING TO BEAR ON FIRM <br />°. UNDISTURBED SOIL <br />. a' . MIN 112" <br />//\//\//\//\//�\// <br />\-• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE VERTICAL <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />w <br />r / U <br />>/\\\// //\\ I Q Q o <br />VAPOR BARRIER LU � o LO <br />X <br />/\\ a <br />i\// <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.\/\\ <br />4 TO 5 COURSES: 48" O.C.\�/��// <br />N <br />/%\ j p• n L a %/\\% <br />FOOTING TO BEAR ON FIRM //� / ADDITIONAL #4 OR#5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT - 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY, EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />- <br />U-BLOCK W/ <br />J <br />(1)#4OR#5 <br />W <br />CONT <br />Lu Lu <br />o � <br />FINISH <br />_ O <br />GRADE <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL OR <br />#5 IN BRICK LEDGE <br />E <br />VERT REINFORCEMENT TO -- <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS -- <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />3'/i' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90' BEND @ 48" O.C. <br />°a <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION ' <br />IN BRICK LOCATIONS - b <br />ON FND PLAN <br />12" UNDER 1 STORY WALL W/ <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE <br />it <br />16" UNDER 2 STORY WALL W/ ( <br />I#4 OR (2) #5 CONT <br />MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE": IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />Ab <br />\o <br />VAPOR BARRIER \�/\ <br />\ <br />SEE NOTES (MAX 16") <br />U <br />0 <br />STUCCO OR DIRECTLY ADHERED vi <br />STONE CLADDING FINISH - MIN 6" rn <br />Cp ALL OTHER EXTERIOR WALL �' LLO <br />CLADDING - MIN 8", U.N.O. ON ARCH ti <br />/ APEX <br />W <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK U) <br />FIRM UNDISTURBED LOCATIONS ON FIND PLAN <br />SOIL m <br />12" UNDER 1 STORY WALL w/ W <br />W <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />W <br />BAR IN BRICK LEDGE <br />Z <br />16" UNDER 2 STORY WALL w/ CD <br />(2) #5 OR (3) #4 CONTINUOUS Z <br />W tds <br />1 MONOLITHIC FOOTING SECTION Q true design studios <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE 0 <br />FOLLOWING OCCUR: l0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" _j 9000 REGENCY SQUARE BLVD. <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY W SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Z 904.821.5200 <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />H <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH O <br />rORIHOMN' <br />o <br />R <br />VAPOR BARRIER i <br />LL <br />Q <br />a) <br />3 BEARING WALL FOOTING SECTION Z <br />r <br />C� <br />O <br />CONCRETE SLAB W/ 6x6 J <br />W1.4 x W1.4 WWF OR O <br />FIBERMESH Z This item has been electronically <br />= signed and sealed by Justin M Lanier, <br />0'-0" A.F.F. PE on the date and/or time stamp <br />SEE ARCH U shown using a digital signature. <br />° a \a DETAILS W Printed copies of this document are <br />F- not considered signed and sealed <br />/ nd the signature must be verified <br />8" MIN W Wby <br />a 3rd Party Certificate Authority <br />py <br />n any electronic co <br />Q U) <br />8"x8" THICKENED 8" O W <br />FTG AT <br />STEP-DOWN, SEE VAPOR BARRIER <br />PLAN m <br />CURB STEP SECTION � W4 - z o_ U) <br />8" UNDER MASONRY WALL OLU 0 <br />m o <br />> <br />CONCRETE SLAB W/ i i 6" UNDER WOOD WALL Z Q <br />6x6 W1.4 x W1.4 WWF I W <br />_ - <br />OR FIBERMESH VARIES = a U) J W <br />SEE ARCH <br />-- ° a- ° (MAX 16") 0 I ' I <br />.4 I ' ' W <br />MIN\\/\\/\\/\\/\� U W <br />VAPOR BARRIER d <br />X <br />6" OPT. EXTENSION IN BRICK i- <br />LOCATIONS ON FND PLAN U' <br />O ZO <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS - ADDITIONAL NO.4 OR NO. 5 Z 0 <br />--- BAR IN BRICK LEDGE = LLI <br />16" UNDER 2 STORY WALL w/ U <br />(2) #5 OR (3) #4 CONTINUOUS Z <br />Abbot Park Ix <br />a <br />5 GARAGE EXT WALL CURB SECTION ___ _ <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE a- LOT 004-04-1 C W <br />FOLLOWING OCCUR: Q J <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" Q <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY 0 <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />CONCRETE SLAB W/ 6x6 PROJECT NO, < <br />W1.4 x W1.4 WWF OR 2021.014964 z <br />FIBERMESH _ U' <br />I--- .___. a0'-0" A.F-.FSEE ARCH D-RAW-N- <br />: <br />MRB <br />�(MAX 20" W <br />d DEEP) <br />CHKD: <br />\/ JAC O <br />\\ \\/\\ k ° / - -- <br />/ <br />4" EXTENSION L <br />UNDER BRICK VENEER <br />U) <br />12" UNDER 1 STORY WALL ,.%�S�C�N BAN/F ��, J <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER :�� �.•�� G E N s�,9 ��' <br />Q <br />U <br />16" UNDER 2 STORY WALL ���i��ed tiy: U) <br />w/ (3) #4 OR (2) #5 CONT * ;, . ; * U) <br />BEARING CURB STEP SECTION �-° ' r.lp? Z <br />6 - qq�-�EE pp <br />Q`;••�T3F4871DPCR16�3J.. Q <br />TYPICAL REINFORCING SS,ONA' r � <br />BARS AT THICKENED W12/29/2021 O <br />FOOTING, SEE PLAN Z <br />I I I <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH REVISIONS: < <br />OF SLAB, TYP ALL _- <br />RE-ENTRANT CORNERS No. Description Date o <br />HOUSE SLAB -- - J <br />Q <br />RE-ENTRANT CORNER DETAIL U) <br />(RECOMMENDED) Z <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS ST=2mD Q <br />CMU/METAL CONNECTOR ENGINEERING <br />