Laserfiche WebLink
m <br />�Ia <br />E <br />I <br />N <br />r7 <br />w <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />914 copper to lights & outlets <br />1 <br />20000 4MP #12 copper to 20 amp ckts <br />A <br /># 10-2 copper to W H <br />#10-3 copper,o Dryer <br />METER II <br />MAIN V <br />2/0 or 4I0 SER AIu <br />200 amp <br />150 amp <br />I <br />POWER CO. FEED <br />I <br />t <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER 5P WITH CODE APPROVED <br />NEC 14,250.94 J CLAMP PER 250.50 AND <br />r <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />WP DISC. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />GFI H.B. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an AC PAD <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing - <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY PA ro <br />DUPLEX CONVENIENCE OUTLET 1 <br />DUPLEX OUTLET ABOVE COUNTER \ <br />� w P WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />I� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />\ 3 - xGFI ' U TP L --'WGFI <br />\ c- RANGE <br />\ \ PENDANT AS / ` PER SPECS *Tc' <br />HEr <br />U. . SWITCH <br />/ - — F R DISPOSAL <br />\ SINK Vvl DISP <br />F <br />\ I I D.W. I o GI <br />\ ' \ GFI L= _�-------- GF--- <br />__--_--T <br />GFl <br />r-� : OPT.I <br />REF. <br />U.C. OUTLET <br />U.C. OUTLET <br />I FOR DW <br />WALL MOUNTED LIGHT FIXTURE C.M <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS CSD <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />,Q EXHAUST FAN/LIGHT COMBINATION <br />rs <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />�Eg PUSH BUTTON SWITCH (OPTIONAL) <br />�D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />-j DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />it J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />A9 (1) PHONE LINE, (1) DATA PORT <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />12 <br />FA RM <br />ROUGH -IN FOR \ <br />OPT. CL(;i. FAN/ <br />GHT PRE -WIRED <br />BEDROOM 2\\� <br />� I00 <br />ROUGH -IN FOR 1 - <br />OPT. CLG. FAN/ I / <br />/ LIGHT PRE -WIRE <br />I <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />G I B A PRE -WIRE <br />BED OOM I j'�BE(jRAOL'GHT <br />4 <br />II II 111IMP <br />III �1111111 <br />ala �a � Ilt► ��� <br />S — - — GFI @ 44'r <br />AHU A.F.F. <br />_— — — — — — — — — — — <br />� F- <br />- -�iFI <br />e <br />OPT. � T ; _ ` I} ► I � ` I <br />-I YI ll I <br />D.Ind <br />I I I I <br />\ `---------- <br />VP <br />\ \ � <br />GFI @ 44" <br />ROUGH -IN FOR l A.F.F. <br />OPT. CLG. FAN/ I I GFI FOR <br />\ LIGHT PRE -WIRE I GAR. DOO2 <br />j j j GFI I <br />1 2 CAR GARAGE <br />/ I I <br />OWNERS SUITE -- �1TO q�� i W.I.C. 1 <br />- - 1 0 <br />W H VERIFY LOCATION j <br />I <br />_ _ _ _ IRRIGATION _ _ _ _ <br />I i <br />GFI -----J ELECTRICAL PANEL " <br />�j � � �_, �FI @-44 A.F.F. <br />RECEPT. '—' <br />FOR ALARM VERIFY METER H.B. <br />SYSTEM LOCATION WITH <br />BUILDER <br />GFI <br />I <br />�- ENTRY <br />II <br />MAIN FLOOR ELECTRICAL PLAN_ <br />CD !2 <br />Z <br />Z <br />Z <br />Q <br />d <br />U) zCZ^V), CD <br />W C <br />w <br />(1)(10oU <br />__ <br />0 w <br />U <br />W <br />I r— <br />mN <br />y M <br />m M <br />5 N <br />CD <br />U <br />Q <br />12 <br />o <br />N �O <br />_ p ► <br />yy ((QVn 7, N Z W o0 <br />N�z4't z <br />a � � w <br />o <br />W <br />Uj <br />d <br />Z Q g U3a, Q 50 Z <br />m <br />ZN�ati�, <br />Z Q C <br />LL g � <br />WaN¢ r 94o <br />o Lj U O <br />❑ <br />WWW.FDSENG.COM <br />0 <br />CV <br />N <br />a <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Resldential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L E N N A R <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />5 <br />'o <br />Z d <br />f <br />Z <br />r <br />Wa <br />Q <br />Zoo <br />QayOO� <br />Lu <br />O LLo <br />L <br />c <br />Z <br />^<^ <br />W <br />�S <br />J <br />w <br />rn 3 <br />O <br />i <br />vW <br />U <br />= <br />O <br />g oa <br />P <br />J 0 <br />U- <br />U O <br />T} <br />Z <br />�Z.51 <br />t{,� <br />�7<a <br />aa� <br />Z <br />LL I <br />In <br />Ljj <br />it i <br />a z g <br />J <br />'r <br />!11 <br />X <br />Q <br />U <br />$~� <br />O <br />k <br />00 <br />Z <br />tj <br />se 0 8 <br />co00 <br />Z <br />2 <br />a 2:rn <br />,--1 <br />10. <br />Ln <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION NO. 4n0 <br />SHEET NO. <br />4.0 <br />I .' <br />