My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39631 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39631 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:09:47 PM
Creation date
2/19/2025 10:54:01 AM
Metadata
Fields
Template:
Building Plans
Street #
39631
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20889
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
's <br />o2 <br />i <br />3 <br />a <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />x <br />w <br />g <br />0 <br />t <br />a <br />00 <br />EI <br />c: <br />J <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" <br />11 <br />STUB -OUT FOR O — o <br />1 �-0�� q 9 in <br />GAS METER 8 <br />O 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'4" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />W-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />" TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />k+ <br />w <br />4J <br />V <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIrN;F I INF <br />+ + <br />+ + + t_ + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + 4. <br />+ + + + + + +- + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +� <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ t <br />+ <br />+ + <br />++ <br />+ + <br />+ <br />++ <br />+ + + + + <br />+ <br />+ <br />++ + + + + + + <br />+ <br />+ <br />+ + + + + o <br />+ + <br />+ + + + + .+ <br />+ + + <br />} <br />+ <br />+ + + + + <br />++ <br />+ + + + <br />+ + <br />+ ++++ <br />++ <br />+++ + <br />++++++++ <br />+ <br />U1 <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />BRIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x — lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />+ i max. 4 max. Web Stiffener Fastener Schedule <br />1/8" gap � � -- --- <br />+ Joist Bearing Lo_ cation <br />i Series. Depth End Intermediate <br />+ / -4 BCI 5000s® 111--7/8" 2-8d 3 8d -- <br />Clinch nails '� 9 -1/2- 2-8d — 2-8d <br />when BCI 6000s® 11-7/8" 2-8d 3-8d <br />l "2-8d 5-8d <br />possible BCI 6500s® 14 <br />16" 2-8d __ 6-8d- <br />1) Support back of web during nailing to prevent damage to _— 11-7/8" 2-8d _S_ d <br />web -flange connection. _ O <br />h BCI 14" 2-8d_ 5-8d <br />Ti <br />2) Block solid between joists for full length of span, Tight fit —" __ 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. ] 1-7/8"' 3-16d 3-16d <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2�' min. BCI 90s® 14' 5-16d _5-16d___ <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4 max. 16" 6-16d 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING Ys" GAP - Hangers with side nailing. <br />@ TOP sides b Y 6". -Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />FILL CELL STD. 90D HOOK BOND BEAM <br />kn __.. <br />w <br />a STD. 900 CONT. #5 <br />BAR >I HOOK BAR <br />BOND BEAM STEP <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />code for appropriate <br />1/16" <br />details in <br />One 10d box <br />areas--20 of high <br />or--20 sinker <br />lateral load. <br />nail each side <br />�. <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Provide adequate bearing <br />J for each lapped joist. <br />10d nails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES _\CJ D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />iD " '—' ❑ iD <br />6,A 1Y2" ROUND HOLE MAY s,-76r, DO NOT CUT HOLES <br />BE CUT ANYWHERE 1N CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT OUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D �_SHEATHING <br />i-% <br />PER PLAN <br />COLUMN AND %' <br />CONNECTION ! T` <br />% <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2" ) gap <br />9 <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />8 <br />V-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />V-3" <br />1'-3" <br />V-7" <br />1'-11" <br />2'-4" <br />2'-9" <br />3'-2" <br />3'-7" <br />---- Any 16" joist 12 <br />1'-0" <br />1'-l" <br />1'-2" <br />1'-2" <br />V-3" <br />1'-9" <br />2'•4" <br />2'-11" <br />3'-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />v_ Span (1t) _ 16 <br />V-0" <br />1'-l" <br />1!-2" <br />1'-2" <br />V-7" <br />2'-0" <br />3'-2" <br />W-10" <br />4'-9" <br />5'-7" <br />6'4" <br />7'-2" <br />T <br />20 <br />V-0" <br />1'-l" <br />1'-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'40" <br />5'-11" <br />W-11" <br />7'-11" <br />8'-11" <br />-- 24 <br />V-0" <br />1'4" <br />1'-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />W-10" <br />7'-2" <br />8'-4" <br />W-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %22" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. <br />GIRDER TRUSS <br />7�1 <br />— r 2X TOP PLATE <br />5/8"0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />SIMPSON H10A <br />w/ (18)10d x 1 1/2" <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />REQUIRED) <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />A <br />Backer block (12" wide min.) — SEE FND. PLN. <br />Nail with 10-10d nails. — — SIZE & REINF. <br />\� all tight to top flange. SLEEVE THRU STEM ' ' <br />\\ • .. r G BELOW PIPE VERTICAL THRU FND. <br />SEE PLAN FOR •. . • • • GRADE <br />Joist hanger \ FOUNDATION INFO <br />STEM FOUNDATION <br />rI.� PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4'-0" <br />GRADE @ <br />Filler block. REINF. SEE PLAN CENETERED PIPE <br />�.� ` PLUMBING LINE <br />��, Nail with PENETRATION <br />10-10d nails. ArBacker block required where top N " dmount hanger load exceeds 250 lbs. • ` ° <br />Install tight to top flange. <br />° <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />� �0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />II— • a <br />'00E <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />is Z ••e, • ., <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />°a 1. <br />G °/ as G <br />.a <br />e G <br />° ° o a <br />v <br />SEE FND. PLN. <br />SIZE & REINF. <br />U W <br />z� <br />z <br />a <br />Z <br />c/) C9 <br />Cl <br />Q� <br />C <br />w <br />o <br />,O <br />w <br />(A = <br />U <br />IU <br />mo <br />M M <br />= <br />N <br />¢ <br />�o <br />U�f � <br />Oi d <br />D D. <br />N _C . B ;D•fC <br />A N <br />M0z'' ki z <br />IJL t+ Lo <br />a <br />�Z0 <br />� WWW.CD C M � • �•� <br />OF �. <br />. M <br />ol <br />sllo��� <br />To the best of ft Engineers knowledge, Information and ballet, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential eth Edition. Engineers signature and seal Is only for <br />the structural engineedng portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />g I", <br />P <br />g$ <br />Sao <br />�o v <br />L_ <br />> <br />LLJ <br />F— <br />g® <br />o <br />U <br />0+ <br />N <br />U) <br />J <br />ri <br />r-I <br />LJ.I <br />41` <br />O <br />Z <br />Z� <br />itn <br />O <br />r <br />00 <br />Z <br />g <br />ICL <br />W <br />= <br />.--+ <br />in <br />o <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION N0. 4n0 <br />SHEET NO. <br />SIN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.