Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />014 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />0,912 copper to 20 amp ckta <br />01 Y10.2 copper to WH <br />00 #10.3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Au, <br />amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER <br />NEC 14, 250.94 JJ <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed In corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />F I GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />g SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />0 <br />WALL SWITCH <br />THREE-WAY SWITCH <br />F3 <br />Q ?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />$ WALL MOUNTED LIGHT FIXTURE <br />J <br />o @)RECESSED LIGHT FIXTURE <br />P c LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�, ®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />4 <br />CH CHIMES (OPTIONAL) <br />N <br />HP PUSH BUTTON SWITCH (OPTIONAL) <br />o PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />e <br />ELECTRIC METER <br />.a ELECTRIC PANEL <br />DISCONNECT SWITCH <br />N <br />� ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J OPT. CEILING FAN <br />5 GD (1) PHONE LINE, (1) DATA PORT <br />AC PAD <br />DISC. <br />WP <br />GFI <br />►LV& <br />H.B. <br />W.I.C. ):�_ -- — , <br />I <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />' LIGHT PRE -WIRE <br />1 11�1 12 <br />OWiRt�, <br />SUITE <br />I <br />k � <br />S.D <br />VERIFY METER LOCATION <br />WITH BUILDER <br />I <br />BEDROOM 2 BEDOOM <br />ROUGH -IN FOR ROUGH -IN FOR <br />- _-- — ' I OPT. CLG. FAN/ f/ OPT. CLG. FAN/ <br />0CMII I LIGHT PRE-WIR&\ %% ` LIGHT PRE -WIRE <br />ROUGH -IN FOR"" 12 I I / 11_� 12 <br />•��- - -�- OPT. CLG.�tD*OM <br />-WN/ r LIG <br />� I 4HTPRE-IR <br />l/ <br />IiI <br />S.D S.D <br />DEDICATED RECEPTACLE / <br />O FOR MICROWAVE RANGE G <br />HOOD PER SPECS_- - / HALL / <br />- - --- <br />�I- - - �I_ _ .-. G I -�-- FI @ 44"7�1—__ 1_- _ ____ - A.F.F. <br />a la�ll, <br />.. r <br />400, <br />;�a • ;ail, �DISP FS <br />I Ii\ <br />Ely <br />--- — -- - -- L I _ <br />I � / <br />I / <br />/ ROUGH -IN F�R / <br />/ OPT. CLG. F N/ LIGHT / 7-0" <br />/ PRE -WIRE I <br />/-- --------------------------------- <br />PATIO <br />PENDANT AS <br />/ PER SPECS <br />tr�/ FAMILY ROOM <br />CAFE <br />/ <br />i <br />3 i <br />i <br />i <br />i <br />i <br />1T' <br />L i i <br />D <br />ow------------ <br />�a I <br />V a I <br />OJ U I <br />I <br />it I <br />WV I <br />W 2-CAR GARAGE <br />FI @ 44" <br />A.F.F. <br />/ GARAGE 1 I <br />/ LIGHT AS I GARAGE <br />/ PER SPECS DOOR <br />/ I GFI <br />� � I <br />I <br />I <br />I A I <br />I l l I <br />II <br />I <br />I 1 11lI <br />I <br />L------------ <br />GFI @ 44" A.F.F. <br />(� IRRIGATION <br />'WWP <br />--{ --- - - r- - -- - - - GFI I <br />- - - ENTRY <br />H.B. <br />MAIN ELECTRICAL PLAN <br />Z g <br />Z <br />Q <br />13 <br />Z <br />c9 <br />L^n' <br />aj cn <br />w <br />�o <br />•V — <br />OLU <br />rz <br />� � <br />,N U <br />LLJ <br />' — <br />= <br />M <br />mN <br />{p <br />r N <br />r�prNyfy <br />U <br />LL� <br />� o <br />�Npp• N <br />Z ` 1„92Z <br />U <br />12 <br />r yLJL. <br />W a_ 2 <br />10go¢¢ <br />p <br />i^m <br />LLto . Z H R<� a <br />10 a Nab. o <br />U <br />WWW,FDSENG.COM <br />00 <br />w <br />N <br />To the best of the Engineers knowledge, information and belief. <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />ReNdential 0th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33601 <br />www.LennarTampa.com <br />W <br />ung <br />O11 <br />W <br />Qz <br />� <br />r <br />> <br />CL <br />Z <br />oC <br />e"'\ <br />Q <br />w <br />W <br />. <br />pg� <br />F P <br />y <br />J `a. <br />Z <br />r-1 <br />Lij <br />z <br />Z8 <br />tj <br />o <br />m <br />O <br />Z <br />g <br />= <br />T-4 <br />a <br />V) <br />o <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION N0. 4nO <br />SHEET NO. <br />4.0 <br />