ROOF FINISH <br />PER ELEVATION <br />12 <br />15 ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL <br />6 <br />4 =1 <br />1-011 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5 MANUFACTURED <br />ROOF TRUSS <br />e; MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL <br />713/4 <br />= <br />- <br />(V <br />o <br />N <br />CV <br />N <br />at <br />1,-4„ <br />FALSE FOAM LOUVER DETAIL TYP <br />28 <br />OL 6" <br />1" <br />4„ 1" 4, <br />fV <br />CV <br />O QO <br />O 00 <br />EPS <br />iv <br />FOAM <br />BRACKET DETAIL <br />9 <br />NOT USED <br />10 <br />4 = 1V Oil <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />STAGGERED <br />CV <br />0 o 0 <br />o " <br />8" <br />LEDGER DETAIL <br />11 <br />1 CASING BEAD <br />7/8" STUCCO WITH WEEP <br />4" STUCCO OVER FRAME SCREED OVER <br />BAND FLASHING <br />WEEP <br />SCREED <br />2 <br />o W <br />N = <br />z <br />2 1'-1 <br />4" STUCCO <br />BAND <br />5/8" <br />STUCCO <br />OVER <br />MASONRY <br />12 <br />51 __ <br />■ <br />FRONT ELEVATION B <br />1 /4" = 1'-011 <br />ELEV AT 8'-8" <br />T.O.M. V <br />—MID WALL <br />WEEP SCREED <br />5/8" STUCCO <br />�_ OVER <br />MASONRY <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />`—GRADE LINE <br />3 REAR ELEVATION B <br />1 /8 = 11-011 <br />_ m�N <br />Il�liil �p 1 � ,■ <br />ill l■IIIII ■IIIII■II <br />III IIIIIII11111■1111 <br />I'p 11 II�I�I 1111 • - • OINT <br />11 I■I■111nn 11■111■11 <br />n m■n�■�ui <br />. STUCCO ■ <br />OVER ■ <br />■ <br />1 /811 = 1 '-011 <br />F- Ir <br />12'-0" <br />N = <br />z <br />12 <br />51 <br />A/C UNIT 2'-0" <br />AND PADtT <br />- <br />i` <br />2h <br />%/8" STUCCO <br />OVER <br />MASONRY <br />LEFT ELEVATION B <br />1 /811 = 1 1-011 <br />13'-4" <br />1 <br />SHINGLE <br />ROOF <br />12 <br />16'-8" <br />�-7/8" STUCCO <br />OVER FRAME <br />CONTROL JOINT <br />MID WALL <br />WEEP SCREED 9 <br />GRADE LINE <br />A5 <br />_ ELEV AT 18'-0" <br />T.O.P. <br />CASING BEAD WITH <br />—WEEP SCREED OVER <br />FLASHING <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />_ ELEV AT 8'-8" <br />T.O.M. <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />-� ELEV AT 8'-8" <br />® T.O.M. <br />2'-0" <br />--A/C UNIT <br />AND PAD <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />WEEP SCREED <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />�I�111�1�111�1�111�1111�:'�I�I�III�I�III�I�III�I�III�I�III�IIIII�I�11m ELEV AT , <br />� III■IIIU.,_ <br />■IIIII■Illli�,_ <br />111111■IIIII■11111�,. <br />1111■IIIII■IIIII■IIIII■IIIII■U111■IIIII■IIIII■IIIII■1111 � � � <br />• •" STUCCO <br />- ' III■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIIIL,. <br />1■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■111 . .. - FF\ <br />111111■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII■IIIII <br />CONTROL • � 1�giliii�:imil: <br />I■IIIII■IIIII■I■III■II11111.11111■11111■IIIII.IIIII■III , <br />��■.nr1nnr,n■1r,■auum■u�rumn■inn■�■nnrIun <br />• \ <br />MID WALL <br />WEEP SCREED <br />------------------ <br />GRADE LINE <br />_ ELEV AT 0'-0" <br />1 ST FLOOR FF <br />APR 0 8 2023 <br />VR//\ <br />Virtual Review Assist, Inc. <br />Plans Review cc!npleted and appro <br />for c0 r,pliance with the 2020 FBC 7th Edition <br />bY, Debra Anne Klahr PX2300 <br />A G, n', <br />ROOF PLAN B <br />1 /811 = 1'-011 <br />G,1 A A" <br />1'-0" <br />1'-0'0�yr <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM)) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2, AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />ROOF GENERAL NOTES: <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER 7TH EDITION (2020) FBC, SECTION R806 <br />FORMULA = S.F. / 300 (1 /300) * 144 (TO CONVERT TO SQ. INCHES) _ <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA 1 = 1268 SQ FT <br />VENTILATION REQUIRED = 609 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 306 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =1197 SQ IN <br />ATTIC AREA 2 = 445 SQ FT <br />VENTILATION REQUIRED = 214 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 108 SQ IN <br />VENTILATION PROVIDED AT SOFFI\T,=425 SQ IN <br />ATTIC V <br />VENTILATION <br />ATTIC VENTILATION TOBCOMPLIANCE LORIDA <br />BUILDING CODE 7TH EDITION (2020) RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1 /300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET MEASURE <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />(VALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />* RIDGE VENTS - 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />* OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />* SOFFIT VENTS - 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />* LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACEABILITY TO MANUFACTURER AND PRODUCT <br />3. C7 <br />N <br />• <br />J DOy , .. <br />1' • <br />►O <br />00 <br />� A <br />G <br />0 <br />w <br />0 <br />Q <br />0 <br />N 1 E <br />i o o 0 <br />_W <br />L <br />M N ti <br />5 `0 2 8 <br />U�0 Q <br />_S <br />• L^n` <br />V w a <br />0 E� <br />7W <br />>. .m <br />w <br />O�LL(DW 02<X<UO0jO <br />�JLL <br />QI- <br />a <br />3WO9ZztRooJ9k <br />L(LmWWWMX<O <br />~U <br />O CY <br />Z <br />�z9KwzwUO0 <br />JO <br />aQ <br />LL <br />< 2co gLU23p <br />Ow O z <br />Q <br />0 <br />w <br />R <br />0 <br />0 <br />z W <br />O F- <br />( Z) ti <br />0 <br />0 ( <br />Q w M � <br />LL <br />W ti <br />F_ W m M <br />Z U <br />W <br />J <br />N <br />N <br />N <br />N <br />N <br />N <br />ti <br />N <br />4 <br />� <br />4 <br />� <br />000 <br />O <br />CD <br />o <br />c6 <br />6 <br />co <br />Cfl <br />Op <br />O <br />N <br />O <br />N <br />O <br />N <br />r <br />N <br />� <br />N <br />O <br />CV <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />CV <br />O <br />N <br />CA <br />CV <br />o0 <br />O <br />L6 <br />00 <br />O <br />A <br />, <br />r <br />N <br />O <br />M <br />OO <br />C D <br />O <br />.- <br />�- <br />O <br />O <br />NLo <br />; <br />o <br />0 <br />0 <br />0 <br />'IT <br />0 <br />0 <br />0 <br />Lo <br />N <br />m <br />Lo <br />O <br />1`�_ <br />COtn <br />z Z <br />-Zo <br />_ <br />O-� <br />WU�'- <br />oW�n <br />�0 <br />LAD M <br />ZWF=-Q <br />co <br />�Z� <br />�mzIx <br />0_zzu- <br />W <br />O�2z <br />O <br />M <br />U�>_W <br />z <br />�QO <br />� <br />z <br />U <br />v <br />:5O <br />O <br />F- W <br />< <br />Q <br />Z <br />Z <br />z <br />W <br />J <br />M <br />N <br />W <br />V-- <br />LAST PLOT DATE <br />Mar. 9, 23 ' <br />O <br />z 0 <br />EXTERIOR <br />ELEVATIONS B & <br />ROOF PLAN <br />