My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6298 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6298 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:28:27 PM
Creation date
2/19/2025 10:55:22 AM
Metadata
Fields
Template:
Building Plans
Street #
6298
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
6334
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12 <br />5� <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />12 <br />�5 <br />EXTERIOR PLASTER SHUTTER <br />ON FRAME �I °0 <br />1/2 33 SH I FLASHING DETAIL 12 � -� <br />—12 <br />5� <br />- — — — '-0' -- <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />SCORED STUCCO <br />BANDS <br />ao <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />�5 <br />H 25 SH <br />— — — 2ND FIN. FLR. <br />i <br />0911 <br />HDR. HGT <br />I <br />7FE: <br />STUCCO BANDS <br />'170 <br />�Z �Dc N <br />16070 OVERHEAD DOOR <br />FRONT ELEVATION — ELEV—A <br />SCALE: 1/4" = V-0" <br />ii0 <br />00 <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />SCORED <br />STUCCO <br />BANDS <br />i <br />SILL DETAIL <br />SCALE: 3/4" = V-0" <br />SCORED <br />STUCCO <br />BANDS <br />HEAD DETAIL <br />SCALE: 3/4" = V-0" <br />SCORED <br />STUCCr <br />BAND <br />t< 1'-6" <br />DECO SHUTTER <br />SCALE: 3/4" = V-0" <br />-----------------------------T.O.P <br />HDR. <br />----------------------------------- <br />I•tH I 1 7 2023 <br />Virtual Review Assist, Inc. plans Review completed and approved <br />LEFT ELEVATION — ELEV—A �t►r c" biance wity Debra AnneeKlahr PX2300 Edition <br />SCALE: 1/4" = V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />overing <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2' lorig, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4%1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />to <br />.......... S.� <br />� <br />J <br />M <br />•Q <br />U <br />� <br />eP <br />� <br />• <br />� <br />�' <br />"tip <br />ROFESSIO14 <br />`�`'�`Rltflftllltlltee�i��! <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />a <br />o <br />0 <br />N� <br />I» <br />M C) # LL <br />Q <br />C J LL W <br />_J L <br />ti <br />Z <br />��°� a <br />o <br />W <br />_cc <br />? o <br />N <br />O <br />O' <br />ILZ <br />v�i pj Co <br />� NZa <br />ZN <br />or- <br />OU 9 U <br />W <br />0 0 <br />V M r <br />Z N ffi <br />z <br />J — <br />�.- <br />Ln <br />m <br />Z <br />0 <br />W <br />V) <br />Ly N <br />® <br />U <br />11J J <br />E <br />z 8 <br />� <br />U <br />c Cn <br />• <br />Q 0 <br />N !9 <br />M <br />J� <br />0 <br />o <br />ZZZ <br />LL <br />n. O <br />zo <br />W. <br />}� <br />E U <br />w° <br />z <br />z® <br />oa <br />~ ro <br />CC <br />O E <br />o <br />o4 <br />a Q <br />Uo <br />�Z <br />¢ Z <br />Z <br />co ro <br />a z <br />0 <br />w z <br />Cn c <br />� <br />�� <br />�S¢ <br />U <br />w� <br />°mo <br />Z <br />Z <br />Z <br />m Q% <br />J <br />N O <br />¢ <br />~°o <br />Q W <br />Zz <br />W <br />CY <br />�3 <br />LL <br />SO <br />Nw <br />LL <br />M. <br />z <br />a r <br />0 <br />c O <br />Ina <br />> (Yi <br />O <br />rn <br />m <br />m <br />C9 <br />L.n <br />Co <br />.-. <br />N <br />o <br />Q <br />Cr Y <br />o <br />N <br />U) m <br />�, <br />N <br />LO <br />O <br />ILL <br />� <br />U M <br />O <br />0000 <br />LO <br />N <br />rn N <br />04 <br />r <br />E <br />t0 <br />c <br />r <br />Z <br />Z <br />E M <br />E <br />M <br />a <br />U 0 <br />q p <br />JOB <br />NO: <br />23-00514 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.