Laserfiche WebLink
A/C <br />DISCONNECT <br />WP <br />GFI <br />HDMI <br />LIVING <br />ROOMi <br />.1 <br />rvvvrt <br />BATHS <br />2'-6" �L� <br />ENTRY GFI <br />_ - - -WP <br />FI <br />bo <br />GFI AT <br />30" A F.F. <br />FII 1 GFIf <br />I PANTRY <br />I� <br />DW ' �- <br />® 1 <br />_TO <br />- ISP <br />LIL <br />GFI AT I ! <br />30 A. . F. <br />'4 <br />— .5--Vl 4'-3" <br />KITCHEN <br />6'-0" - <br />A <br />co . GFI <br />DINING <br />ROOM <br />FI <br />GFI n 0 _U <br />/ C <br />ELEC <br />PANEL <br />TWO CAR GARAGE I <br />I. <br />48 <br />o I <br />`V I GFI <br />GFI <br />110V CLG <br />I <br />i MNT. <br />---!--- OUTLET---- <br />I I I <br />I � I <br />L------------------- I <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /4" = 1 '-0" <br />ELEC <br />METER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NCTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL, BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />C <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />AUG 2 4 222 <br />\v/-R,A <br />vIRTUAL REVIEW ASSf, <br />Virtual Revle'uv <br />Plans Review ccm ., <br />for compliance wrO� kr.r 2 t, Lf rl1 <br />Edition by Debra Anne-- K4a�7w <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH-,,— <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />kS�' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�{ TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />i 3 WAY SWITCH AT 36" <br />-E4- 4 WAY SWITCH AT 36" <br />--C PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />-�- CLG MNT LT FIXTURE <br />-}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-}- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />4) " USED IF 50W PAR30 NFL 6WHITE BAFFLE <br />C APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />moo) 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-�- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SS SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />I- 48 48"CLG MNT WRAPPED FLUOR LIGHT <br />IF 24 :R 24" VANITY LIGHTING <br />9;;F36:FFR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />LC_ DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />IZ VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />M A/C REGISTER <br />(T� THERMOSTAT <br />TO SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />to <br />N L0 E <br />r-'? o <br />Q\� L <br />c;.M <br />4__;� <br />to <br />) <br />tj (y) <br />V <br />A' •L.� L O <br />U� <br />—s <br />•N <br />U W Q N C <br />7W� <br />L 0 E v� m <br />w <br />w <br />❑LLI LL1 Uj wOf- <br />H~ w�� 0 ¢<Z= Z <br />ofom�<cQwU-p00-j0 <br />Q la- <br />U <br />00p0fo�oEoom❑zaa <br />O <br />OZ <br />UOa�ZYw❑�_ w<00 <br />Z�YZQQ❑Q <br />a <br />¢0W0�~F <br />p� 0 ❑ ❑Q CC <br />`� <br />LL Q 0 tL <br />O <br />O <br />Z N <br />Ow <br />F- <br />C ti <br />- <br />FM O <br />Q L') <br />w LL <br />ti <br />W <br />I- of a. M <br />O <br />Z V <br />Z <br />w <br />w� <br />J O <br />N <br />I <br />I <br />I <br />N <br />N <br />00000 <br />ti <br />N <br />N <br />O <br />� <br />O <br />O <br />o <br />C, <br />O <br />N <br />O <br />' <br />z <br />O <br />wLo <br />0 <br />0 <br />0 <br />0 <br />0 <br />1 <br />> <br />N <br />M <br />d' <br />6 <br />CO <br />w <br />}~ <br />ZZ <br />a w <br />o�--+ <br />}� <br />W <br />Z <br />O <br />U <br />�00 <br />UvZ;5 <br />�. <br />z)z j <br />O <br />g <br />ooLr <br />Q <br />Za�a <br />N <br />� <br />��w <br />N <br />ZO <br />== <br />w <br />� <br />Q�� <br />Q <br />U <br />:5zLL <br />aLL <br />ry.� <br />Q <br />tom - <br />� <br />OU <br />_0 <br />W <br />z <br />Z <br />z <br />w <br />w <br />J <br />N <br />N <br />LAST PLOT DATE <br />O <br />• <br />April 25, 2022 <br />z <br />0 <br />1 ST FLOOR <br />'= <br />ELECTRICAL PLAN B <br />■R11■ <br />