My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6309 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6309 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:53:19 AM
Creation date
2/19/2025 10:56:01 AM
Metadata
Fields
Template:
Building Plans
Street #
6309
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5277
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r; <br />4' <br />6'-7" <br />DISCONNECT <br />WP <br />GFI <br />FAMILY <br />ROOM <br />- F •�� <br />C V <br />OWNER <br />SUITE <br />KITCHEN <br />GFI AT <br />77 <br />30" A.F.F. db <br />I <br />I <br />III1U <br />I <br />I <br />I <br />I <br />o <br />TO <br />co <br />� <br />I <br />' <br />7PP <br />B <br />0 <br />0 <br />C5. <br />DINING. <br />' <br />---- <br />ROOM <br />GFI A <br />I <br />: <br />- <br />30" A.F.F.: <br />__p_ <br />I <br />v <br />T-8" <br />T. <br />?P4W�D <br />2'-3" <br />A <br />N <br />OS.� M <br />TO 2ND <br />FLR ELEC <br />l <br />' LINE OF <br />FLOOR <br />ABOVE <br />0 <br />FOYER <br />I <br />r <br />�a <br />ENTRY [�WP <br />ANTRY UTILITY <br />J�GFV <br />A A <br />2'-4" r3'-l" �, N G <br />6'-5" <br />ail <br />LIGHT AND <br />_ SWITCH IN 0 <br />�- — ATTIC <br />10 <br />I L—'— — J ELEC <br />I PANEL <br />110V CLG <br />9 ' MNT. <br />OUTLET <br />I <br />GFI <br />i <br />I <br />I i <br />I _ I <br />C) I <br />I 4 <br />uo <br />I I <br />i <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0" <br />METER <br />LINE OF ROOF <br />Mr[ �IAI <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /411 = 11-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />01 <br />#15 copper to lights & outlets <br />NEMA 1 01 <br />200 AMP <br />#12 copper to 20 amp ckts <br />10 <br />#10-2 copper to WH <br />01 <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Aiu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />SEP 0 8 2022 <br />> <br />VIRTUAL Rc�!LW A 31e\3. r <br />Virtual Rev i(1: w A s Q . <br />Plans Review' c-omoleted ai,d <br />for compliance'with the 2020 FBC 7', <br />Edition by Debra Anne Klahr PX2'-: o <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1 /2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM --- <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />{- CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />-} SURFACE MNT FIXTURE <br />}- WALL MNT FIXTURE <br />NOTE: <br />0 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />60 50W MR16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />�} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />-U-18m UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9F24:R 24" VANITY LIGHTING <br />5;;;: 36 :FR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />ti� DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />11&3 ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />ED A/C REGISTER <br />l0 THERMOSTAT <br />ED SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br /><55 <br /><Z50 <br />" o <br />a0 <br />LO <br />t _3 <br />z <br />Uj <br />'. <br />0 <br />w <br />0 <br />z <br />Q <br />V) 4)E <br />a) 6. 'O C`? U <br />`T M v ai <br />me. <br />rMO <br />B <br />_O <br />U <br />.t <br />•nN` LU Q'N C <br />W i 00 EM <br />70 a ^1)aac <br />LU W <br />Lu <br />JwZXU_?�z <br />0 LU <br />OaU_VO_,0 <br />aWw 0LL <br />0 <br />0 Z <br />0n.�V5wwWV5It <br />_~WO<0zizowVw� <br />¢0 <br />LL <br />O o =5HP <br />LL� 0 �QLL <br />0 <br />Z w <br />01-- <br />(n O <br />CY) <br />Q i/d. LO <br />H w M_ <br />Q>- <br />QQO <br />Z U <br />w <br />W <br />J O <br />0 <br />N <br />N <br />0 <br />N <br />ti <br />N <br />O <br />O <br />ao <br />CO <br />o0 <br />O <br />O <br />O <br />r- <br />•" <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />o <br />N <br />0 <br />CV <br />0 <br />N <br />0 <br />N <br />6 <br />N <br />00 <br />O <br />Lh <br />I*M <br />O <br />� <br />N <br />O <br />M <br />N <br />a� <br />o <br />O <br />cfl <br />C <br />'^ <br />Y / <br />; <br />0 <br />0 <br />0 <br />M <br />0 <br />0 <br />0 <br />0 <br />N <br />d <br />tci <br />C0 <br />I� <br />Cr <br />CO <br />(n <br />Z Z <br />owO <br />_ <br />e <br />O <br />vo�� <br />�O00 <br />Q <br />d <br />Lr)Z <br />^ <br />i.� <br />rr�� <br />V / <br />O <br />W x: '7 <br />H <br />Q <br />F- W <br />N <br />l�nm0Z <br />V <br />Z W <br />00 <br />5.<W0 <br />iYi <br />�ZZLL <br />CV <br />w N <br />Og2z <br />z <br />U�->_C0 <br />=<O <br />U <br />3i <br />Z <br />:5Ov <br />O <br />W <br />� <br />Z <br />Uj <br />w <br />J <br />N <br />W <br />N <br />t— <br />LAST PLOT DATE <br />Apr. 26, 22 <br />z <br />0 <br />1 ST & 2ND FLOOR <br />J <br />ELECTRICAL <br />PLAN <br />B <br />
The URL can be used to link to this page
Your browser does not support the video tag.