Laserfiche WebLink
SPEC IFIGATIONS <br />I. I. CONSTRUCTION <br />I. I. I. AGI 30-14 BUILDING GORE REQUIREMENTS FOR 5TRUGTURAL CONCRETE <br />I. I. 2. A5GE5/AGI 530-13, TMS 402-I6 8 A5GE6/AGI 530.1-15, TM5 602-16 <br />SPECIFICATIONS FOR MA50NRY STRUCTURE5. <br />I. 1.5. ASTM G270-12a, G476-10, AND Gq0-14 SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. 1. 4. NATIONAL DESIGN 5PEGIFIGATION5 (ND5) FOR HOOD GON5TRUGTION, 2015 EDITION, AND ALL <br />AGGOMPANYING SUPPLEMENTS. <br />I. I. 5. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING GODE (FBG), 6th EDITION (2017) <br />I. 1. 6. "MANUAL OF STEEL GON5TRUGTION, ALLOHABLE 5TRE55 DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL GON5TRUGTION, (AISG) <br />"DESIGN 5PEGIFIGATION FOR LIGHT METAL PLATE GONNEGTED HOOD TRU55E5" BY THE <br />TRUSS PLATE INSTITUTE TPI 1-14. <br />I. 2 . DESIGN : <br />I. 2. I. AGI 31,5-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL GONGRETE <br />I. 2. 2. A5GE5/AGI 530-13, TMS 402-16 $ A5GE6/AGI 530.1-13, TM5 602-16 <br />5PEGIFIGATION5 FOR MASONRY 5TRUGTURE5. <br />I. 2. 3. A5TM G270-12a, G476-10, AND CAO-14 5PEGIFIGATION5 FOR MASONRY 5TRUGTURES <br />I. 2. 4. NATIONAL DESIGN 5PEGIFIGATION5 (ND5) FOR HOOD GON5TRUGTION, 2015 EDITION, AND ALL <br />AGGOMPANYING SUPPLEMENTS. <br />1. 2. 5. PLYHOOP DE51ON 5PEGIFIGATIONS (APA) <br />I. 2. 6. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), 6th EDITION (2017) <br />I. 3. SHOP DRAWINGS: <br />I. 3. I. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP DRANIN05 NITHOUT HRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />I. 5. 2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE GOMMENGEMENT OF GON5TRUGTION. <br />ALL ROOF AND FLOOR TRU55 SHOP DRAHIN65 ARE TO BE SIGNED AND SEALED BY A FLA. <br />REG. PE. AND SHALL INGLUDE : DRANIN05 AND GALGULATIONS, REAGTIONS AND BEARING <br />POINTS, BRAGING REGUIREMENT5, AND GONNEGTIONS TO SUPPORTING TRUSS MEMBERS. <br />2. DESI CN LOADS <br />TH15 5TRUGTURE HAS BEEN DESIGNED IN AGGORDANGE HITH THE 6th ED. (2017) FLORIDA <br />BUILDING CODE, RESIDENTIAL <br />BUILDING GATEGORY: II <br />2.1. DEAD LOADS : <br />ROOF <br />TILE (TG=15P5F, BG=IOP5F) 25PSF <br />ASPHALT SHINGLE (TG=7PSF, BC=IOPSF) 17P5F <br />METAL (TG=IOPSF, BG=IOPSF) 20PSF <br />FLOOR <br />TILE (GERAMIG, 1/2" MORTAR BED) 25P5F <br />CARPET OR HOOD 15PSF <br />2. 2. LIVE LOADS : <br />ROOF <br />20PSF <br />FLOOR <br />ONE- AND TWO-FAMILY DHELLING5 <br />UNINHABITABLE ATTIC, NO STORAGE <br />IOPSF <br />UNINHABITABLE ATTIC, LIMITED STORAGE <br />20P5F <br />HABITABLE ATTICS, SLEEPING AREAS <br />30P5F <br />OTHER <br />40PSF <br />EXTERIOR DECKS <br />SAME AS OGGUPANGY SERVED <br />RAILING - NONGONGURRENT <br />50PLF OR 20OLB <br />LIVE LOAD REDUGTION5 <br />PER CODE <br />2. 3, ROOF SNOW LOAD DATA: <br />GROUND SNON LOAD, Pq = N/A <br />2. 4. WIND LOADS : <br />BASIC, HIND SPEED, V (3-5EG. GUST) <br />140MPH (Va5d=108MPH) <br />HIND EXPOSURE <br />C <br />INTERNAL PRESSURE GOEFFIGIENT <br />V-0.15 <br />C&G DESIGN PRESSURE <br />SEE PLAN <br />HIND BORNE DEBRIS PROTEGTION <br />5HUTTERAMPACT GLA55 <br />2. 5. SEISMIG DESIGN DATA: <br />SEISMIC IMPORTANGE FACTOR, le <br />1.0 <br />SEISMIC, RISK CATEGORY <br />II <br />MAPPED SRA, 55, 51 <br />N/A <br />51TE GLA55 <br />A <br />DESIGN SRG, 5D5, SDI <br />WA <br />SEISMIC, DE515N CATEGORY <br />WA <br />BASIC, 5FRS <br />MASONRY HALLS <br />DE515N BASE SHEAR, (UNFACTORED) <br />WA <br />SEISMIG RESPONSE GOEFFIGIENT, G5 <br />WA <br />RESPONSE MODIFICATION FAGTOR, R <br />WA <br />ANALYSIS PROCEDURE <br />ELF <br />2. 6. FLOOD DESIGN DATA: <br />DATUM NAVD88 <br />FLOOD ZONE "X" <br />BASE FLOOD ELEVATION: N/A <br />LOWEST PROPOSED FLOOR ELEVATIONS WA <br />3. DEFLECTIONS: <br />LIVE LOAD L/360 <br />TOTAL LOAD L/240 <br />4. MATERIALS <br />4.1. RE I NFORG I NG STEEL <br />4. <br />I. I. REINFORGING STEEL SHALL BE A5TM A615/A615M-Og GRADE 40, f'y = 40 Ksi <br />4. <br />1.2. LAP 5PLIGE SHALL BE AS FOLLOH5: #5 BAR 25", #4 BAR 20", #3 BAR 15" <br />4. <br />I. 3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORGING ARE TO THE CENTERLINE OF <br />EACH BAR EXGEPT HHERE THE COVER DIMENSION IS 5HONN TO THE FACE OF THE GONGRETE. <br />4. <br />1.4. REINFORGING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. <br />1.5. REINFORGING MEGHANIGAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. <br />4. <br />I. 6. DESIGN COVER REQUIREMENT5 : <br />G-I-P GONGRETE FORMED AGAINST EARTH 3" <br />G-I-P GONGRETE EXPOSED TO EXTERIOR : 2" <br />G-I-P GONGRETE NOT EXPOSED V2" <br />GROUT FILLED MASONRY : 3/4 <br />HELPED HIRE FABRIC, (HHF): A1064/A1064M-16a <br />4. <br />I. 5. DETAIL REINFORGEMENT IN AGGORDANGE HITH AGI 315-LATEST EDITION. <br />4. 2. GONGRETE : <br />MODULES OF <br />4. 2. I. <br />CONCRETE TYPE <br />MIN. 28 DAY <br />DESIGN (f'c) <br />ELASTIGITY <br />DESIGN (E) <br />C-I-P GONGRETE (NORMAL WEIGHT) <br />2,500 Psl <br />2,850 K51 <br />G-I-P GONGRETE (NORMAL WEIGHT) HERNANDO CO. ONLY <br />5,000 Psi <br />5,122 K51 <br />G-I-P GROUT <br />1 5,000 P5I <br />I 3,122 K51 <br />4. 2. 2. <br />GONGRETE SHALL GONSI5T OF I" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 7" AT TIME OF PLAGEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4. 2. 3. <br />GROUT SHALL GON515T OF PEA ROGK (3/5" MAXIMUM AGGREGATE) GONGRETE MIX <br />WITH SLUMP BETWEEN &" AND 10" AT TIME OF PLAGEMENT. SEE 5PEGIFIGATION5 FOR <br />ADDITIONAL GRITERIA. <br />4. 2. 4. <br />GON5TRUGTION JOINTS HILL BE PERMITTED <br />4. 2. 5. <br />METHOD OF GONGRETE FORMING, PLAGEMENT AND GURING SHALL BE GONDUGTED IN <br />AGGORDANGE HITH THE 5PEGIFIGATIONS AS STATED. <br />4. 2. 6. <br />EARTH SUPPORTED SLAB5 (EXGLUDING EXTERIOR NALKHAY5 $ DRIVEHAY5) <br />3 1/2" MIN. THIGKNE55 W MIN. REINFORGEMENT OF 6.0 x 6.0 H/ 1.4 x 1.4 HHF <br />IN TOP OF 1-1/2" OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. HHF <br />GONTRAGTORS DISGRETION. <br />4. 2. 7. <br />CONCRETE PLAGEMENT PRAGTIGES SHALL BE IN AGGORDANGE H/ ALL <br />AGI- MGP 2017 STANDARDS. <br />4.5. GONGRETE MASONRY : <br />4. 3. I. <br />FILLED CELLS H/ (1) #5 BAR SHALL BE LOCATED PER PLAN. <br />4. 3. 2. <br />LOAD BEARING GONGRETE MASONRY BLOCK SHALL BE A5TM Gq0-14, TYPE II <br />NON -MOISTURE CONTROLLED. <br />4. 5. 3. <br />ALL GELL5 8 GAVITIE5 BELON GRADE HILL BE FILLED H/ GONGRETE IN ALL STEM HALLS <br />4. 3. 4. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 2,000 PSI MINIMUM <br />4. 3. 5. <br />METHOD OF GONGRETE MASONRY PLAGEMENT AND GON5TRUGTION SHALL BE <br />GONDUGTED IN AGGORDANGE HITH THE 5PEGIFIGATIONS AS STATED. <br />4. 3. 6. <br />MORTAR SHALL BE TYPE S" FOR ALL MASONRY GON5TRUGTION. <br />4. 3. 7. <br />MASONRY ROUGH OPENING MAY VARY IN THE GRO55 5EGTION DIMENSION OR ELEVATION <br />DIMEN51ON 5PEGIFIED ON THE APPROVED PLANS FROM -1/4" TO +1/2" PER 5EGTION R606.3.1.1 <br />4.4. STRUCTURAL LUMBER : <br />4. 4. 1.1. <br />INTERIOR LOAD BEARING HALLS SPF STUD OR BETTER, fib = 675 PSI, E = 1200 Ksi <br />ALL EXTERIOR FRAMING 5PF #2 OR BETTER, fb = 875 PSI, E = 1,40OK51 <br />4. 4. 1.2. <br />ALL FRAME HALLS TO BE GON5TRUGTED USING SPF , <br />STUD QUALITY OR BETTER, UNLESS NOTED OTHERHISE <br />4. 4. 2. <br />ALL PLYNOOD USED FOR EXTERIOR APPLICATIONS <br />SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4. 4. 3. <br />ALL PLYNOOD USED FOR INTERIOR APPLICATIONS 5UGH AS SUB FLOORING AND <br />SHEAR HALLS SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4. 4. 4. <br />IF OSB BOARD IS TO BE USED IN PLAGE OF PLYHOOD 15 TO HAVE SIMILAR OR <br />GREATER 5EGTION PROPERTIES. <br />4. 4. 5. <br />ONLY STRUGTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. HOOD IN <br />GONTAGT HITH GONGRETE 15 TO REGEIVE A STANDARD GRADE PRESSURE TREATING. <br />4. 4. 6. <br />HHEN PRE ENGINEERED TRUSSES ARE GALLED FOR ON THE PLANS THE <br />MANUFAGTURER 15 TO SUBMIT SHOP DRANIN05 TO THE ENGINEER OF RECORD. <br />4. 4. 7. <br />DESIGN, FABRIGATE AND ERECT HOOD TRUSSES IN AGGORDANGE HITH THE "DESIGN <br />5PEGIFIGATION FOR LIGHT METAL PLATE GONNEGTED HOOD TRUSSES" BY THE <br />ANSI/TPI 1-14, BG51 2013 <br />4. 4. 6. <br />UNTREATED HOOD SHALL NOT BE IN DIREGT GONTAGT HITH GONGRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS HITHOUT NOODEN TOP PLATES. <br />4. 4. q. <br />ALL EXTERIOR FRAME HALLS SHALL BE 5TUGGO FINISH AND SHALL BE APPLIED IN 5TRIGT <br />AGGORDANGE HITH THE FRG SECTION Ri0532 AND WITH ASTM Gc126 INGLUDING THE <br />REFERENGE IN ASTM Gg26 5EGTION b TO 5EGTION X1.4.2 OF THE APPENDIX - 7/8" TOTAL <br />THIGKNE55 APPLIED IN THREE LAYERS (515" - 5/5" - W5") OVER METAL LATH OVER HATER <br />RE515TIVE BARRIER. THE HATER RESISTIVE BARRIER SHALL INGLUDE A HATER-RE515TIVE <br />VAPOR -PERMEABLE BARRIER HITH A PERFORMANGE AT LEAST EQUIVALENT TO TNO <br />LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />INDEPENDENTLY 5UGH THAT EAGH LAYER PROVIDES A SEPARATE GONTINUOU5 PLANE AND <br />SHALL BE ATTAGHED DIREGTLY TO THE SHEATHING OVER FLASHING INSTALLED IN <br />AGGORDANGE WITH THE APPLICABLE BUILDING CODE AND MANUFAGTURER'S <br />SPECIFICATIONS. GURING TIME FOR 3-GOAT STUGGO, EAGH GOAT SHALL BE KEPT IN A MOIST <br />GONDITION FOR AT LEAST 4b HOURS PRIOR TO THE APPLIGATION OF THE NEXT GOAT. THE <br />2ND GOAT SHALL NOT BE APPLIED SOONER THAN 48 HR5 AFTER APPLIGATION OF THE 15T <br />GOAT. THE FINISH GOAT SHALL NOT BE APPLIED SOONER THAN 7 DAYS AFTER THE <br />APPLIGATION OF THE 2ND GOAT. UNLESS APPLIGATIONS INSTALLED IN AGGORDANGE HITH <br />A5TM Gc126 INGLUDING THE REFERENGE IN ASTM Cc126 5EGTION 8 TO SEGTION XI.4.2 OF THE <br />APPENDIX <br />4. 4. 10. <br />INSTALLATION OF EXTERIOR LATHING a FRAMING SHALL COMPLY TO ASTM G 1063 <br />PER FLORIDA RESIDENTIAL CODE R703.7.1 <br />4. 4. 11. <br />FIELD GUT ENDS, NOTGHES AND DRILLED HOLES OF PRESERVATIVELY TREATED HOOD <br />SHALL BE TREATED IN THE FIELD IN AGGORDANGE HITH ANPA M 4 <br />4. 5. FASTENERS AND TIE DOWNS : <br />4. 5. 1. <br />FASTENERS AND TIE DOHN5 SHALL CONSIST OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, GHANNEL5 : ASTM A36/36M 05 Fy = 36 Ksi <br />ROUND METAL PIPE : ASTM A53/A53M-12, GRADE B Fy = 35 Ksi <br />SQUARE METAL TUBING : A5TM A500-13, GRADE B Fy = 46K51 <br />HIGH STRENGTH BOLTS : ASTM A325-14 <br />MACHINE BOLTS : GALVANIZED ASTM A307-12 <br />4. 5. 2• <br />SHEET METAL AGGE55ORIES SHALL CONFORM TO : Fy = 33K51NITH Gq0 <br />GALVANIZED GOATINO IN AGGORDANGE HITH ASTM A525-g3. <br />4. 5. 3. <br />NAILS SHALL GON515T OF : COMMON HIRE NAILS WITH MINIMUM DIAMETER A5 <br />FOLLOH5 : 8d = 0.131 ", IOd = 0.148", 12d = 0.145", 16d = 0.162" <br />4. 5. 4. <br />ALL FASTENERS AND TIE DOHN5 EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO REGEIVE AN ANTI -GORROS IVE GOATIN6 BY MANUFAGTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DONN5 ARE TO PROVIDE THE UPLIFT GAPAGITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4. 5. 6. <br />ALL FASTENER TIE DOHN5, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN AGGORDANGE HITH THE PLANS AND 5PEGIFIGATION5. <br />4. 5. 7. <br />CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE NET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPAGING AND ALIGNMENT ARE TO BE IN AGGORDANGE <br />HITH THE DE51ON PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. <br />4. 5. b. <br />GONGRETE EMBEDDED TIE DOHN5 USED FOR TRUSS AND HALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORGING PRIOR TO OR WHILE PLAGINS GROUT. <br />4. 5. q. <br />P05T-INSTALLED ANGHOR5 INTO CONCRETE <br />I. POST -INSTALLED ANGHOR5 SHALL ONLY BE USED HHERE 5PEGIFIED ON THE <br />GON5TRUGTION DOGUMENTS. THE GONTRAGTOR SHALL OBTAIN APPROVAL FROM DANSGO <br />ENGINEERING, LEG PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLAGE OF <br />MISSING OR MI5PLAGED CAST-IN-PLAGE ANGHOR5. <br />2. CARE SHALL BE TAKEN IN PLAGINS POST -INSTALLED ANCHORS TO AVOID GONFLIGT5 <br />HITH EXISTING REBAR. <br />3. HOLES SHALL BE DRILLED AND GLEANED IN AGGORDANGE HITH THE MANUFAGTURER'S <br />PRINTED IN5TRUGTION5 (MPII). <br />4. SUBSTITUTION REQUESTS FOR PRODUGT5 OTHER THAN TH05E 5PEGIFIED BELOH SHALL BE <br />SUBMITTED BY THE GONTRAGTOR TO DE ALONG HITH GALGULATION5 THAT ARE <br />PREPARED $ SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE GALGULATIONS <br />SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUGT IS CAPABLE OF AGHIEVINO <br />EQUIVALENT PERFORMANCE (MINIMUM) VALUES OF THE 5PEGIFIED PRODUGT USING THE <br />APPROPRIATE DE51ON PROGEDURE AND/OR STANDARD(5) AS REQUIRED BY THE FLORIDA <br />BUILDING GORE. <br />5. PROVIDE PERIODIC, 5PEGIAL IN5PEGTION FOR THRESHOLD BUILDINGS FOR ALL ADHESIVE <br />AND MEGHANIGAL ANGHOR5 PER THE PRODUGT'S FLORIDA PRODUGT APPROVAL. <br />6. GONTAGT MANUFAGTURER'S REPRESENTATIVE FOR THE INITIAL TRAINING AND <br />INSTALLATION OF ANGHORS AND FOR PRODUGT RELATED QUESTIONS AND AVAILABILITY. <br />GALL SIMPSON 5TRONG-TIE AT (800) qqq-50gg. GALL HILTI AT (866) 445-8827. <br />7. MEGHANIGAL ANCHORS SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE HITH AGI <br />355.2 AND IGG-ES AGIg3 FOR GRAGKED AND UNGRAGKED GONGRETE RECOGNITION. <br />PRE -APPROVED MEGHANIGAL ANGHORS INGLUDE: <br />A) SGREH: SIMP50N STRONG -TIE "TITEN-HD" OR HILTI "KNIK HU5-EZ" <br />B) EXPAN51ON: SIMPSON STRONG -TIE "STRONG -BOLT 2" OR HILTI "KNIK BOLT TZ" <br />8. ADHESIVE ANCHORS SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE HITH AGI <br />355.4 AND IGG-E5 AG305 FOR GRAGKED AND UNGRAGKED CONCRETE RECOGNITION. <br />ADHESIVE ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF 21 <br />DAYS PER AGI 30-14 D.2.2. HOLES SHALL BE DRY AT THE TIME OF INSTALLATION. <br />ADHESIVES SHALL HAVE MAX. IN-5ERVIGE SHORT-TERM TEMPERATURE OF 150°F, AND <br />MAX. IN-5ERVIGE LONG-TERM TEMPERATURE OF 110°F (AGI 315 DA.2.0. PRE -APPROVED <br />ADHESIVE ANGHOR5 INGLUDE: <br />A) EPDXY: SIMP50N STRONG -TIE "5ET-XP" OR HILTI "HIT -RE 500-517" <br />B) FAST GURE: SIMPSON STRONG -TIE "AT-XP" OR HILTI "HIT-HY 200" <br />4.5. 10. <br />POST -INSTALLED ANGHOR5 INTO MA50NRY <br />I. MEGHANIGAL ANCHORS INSTALLED IN SOLID -GROUTED GONGRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 AGOI OR AG10(q. <br />PRE -APPROVED MEGHANIGAL ANCHORS INGLUDE: <br />A) SGREH: 51MP50N STRONG -TIE "TITEN-HD" OR HILTI "KNIK HU5-EZ" <br />B) EXPANSION: SIMP50N STRONG -TIE "5TRON5-BOLT 2", "HEDGE -ALL" OR HILTI <br />"KNIK BOLT 3" <br />2. ADHESIVE ANGHOR5 INSTALLED IN SOLID -GROUTED GONGRETE MASONRY SHALL HAVE <br />BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 AG58. PRE -APPROVED <br />ADHESIVE ANGHOR5 INGLUDE: <br />A) EPDXY: SIMPSON STRONG -TIE "SET-XP" <br />B) FAST CURE: SIMP50N STRONG -TIE "AT-XP" OR HILTI "HIT-HY 70" <br />3. ADHESIVE ANGHOR5 INSTALLED IN HOLLOW CONCRETE MASONRY $ UNREINFORGED CLAY <br />BRIGK MASONRY SHALL HAVE BEEN QUALIFIED FOR USE IN AGGORDANGE HITH IGG-E5 <br />AG58 OR AC60, RE5PEGTIVELY. PRE -APPROVED ADHESIVE ANGHOR5 INGLUDE: <br />A) 51MP50N 5TRONG-TIE "SET" OR HILTI "HIT-HY 70" <br />4. THE APPROPRIATE SCREEN TUBE SHALL BE USED FOR ALL ADHESIVE ANCHORS <br />INSTALLED IN HOLLON GONGRETE MASONRY OR UNREINFORGED CLAY BRIGK MASONRY <br />AS REQUIRED BY THE ADHESIVE MANUFAGTURER. <br />4. 6. MICRO -LAM LUMBER: <br />4. 6. I. <br />MIGRO-LAM 5TRE55 GRADES SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: <br />E = 2,000,000 P51 <br />Fb = 2,g50 P51 <br />Ft = 1,850 PSI <br />Fr_ = 500 PSI (PERPENDIGULAR) <br />Fr_ = 2,700 (PARALLEL) <br />4.1. STEEL: <br />Fv = 255 PSI <br />4. 7. I. <br />INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4. 7. 2• <br />FABRIGATE AND EREGT ALL 5TRUGTURAL STEEL IN AGGORDANGE WITH A.I.S.G. <br />"5PEGIFIGATION FOR THE DESIGN, FABRIGATION, AND EREGTION OF 5TRUGTURAL <br />STEEL FOR BUILDINGS" <br />4. 7. 3. <br />5TRUGTURAL STEEL: A5TM A36/36M 085. <br />4.1. 4. <br />STEEL TUBING: A5TM A500-10, GRADE B. <br />4. T 5. <br />HELPED GONNEGTION5: E70XX ELECTRODES, MINIMUM 5IZE FILLET HELPS 3/16", AHS <br />GERTIFIED HELDER5. GERTIFIGATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4.1. 6. <br />NHERE STEEL BEAMS ARE GONTINUOU5 OVER COLUMNS, PROVIDE NEB STIFFENER <br />PLATES ON EAGH 51DE OF THE WEB, OF A THIGKNE55 EQUAL TO BEAM FLANGE <br />THIGKNE55, LOCATED AT THE GENTER LINE OF THE TUBE COLUMN. <br />THE STEEL FRAME IS "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE GONTRAGTOR UNTIL REQUIRED GONNEGTION5 OR <br />ELEMENTS ARE IN PLAGE. <br />4. 8. SOIL: <br />4. 8. I. THE FOOTING 15 DESIGNED BASE ON 2000 P5F 501L BEARING PRESSURE. <br />GONTRAGTOR/OHNER SHALL VERIFY SOIL BEARING PRESSURE OF THE PROPOSED SITE, <br />4. 8. 2. ALL SOIL 15 TO BE GLEAN 8 POISONED FOR TERMITES PER FBG 6TH EDITION (2017) <br />RESIDENTIAL 5EGTION5 R30.1, R50.2, R318.3, 6 R30.7 <br />TERMITE PROTECTION - <br />PLANS MUST SPECIFY TYPE OF TERMITE TREATMENT <br />• 501L GHEMIGAL BARRIER METHOD <br />• OTHER TREATMENT - MUST 5PEGIFY PROPOSED METHOD AND SUBMIT DOGUMENTATION, HHIG <br />SUBSTANTIATES THE PROPOSED METHOD, 15 AN APPROVED TERMITE PROTEGTION SYSTEM <br />OR METHOD. <br />-IF CHEM I GAL SOIL TERMITE TREATMENT 15 USED <br />I. FBG 105.11- "A PERMANENT SIGN NHIGH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPEGTION AND TREATMENT GONTRAGT RENEHAL SHALL BE <br />PROVIDED. THE 51ON SHALL BE P05TED NEAR THE HATER HEATER OR ELEGTRIG PANEL" <br />2. GONDEN5ATE AND ROOF DOHN5POUT5 SHALL 015GHARSE AT LEAST 1'-0" AWAY FROM <br />THE BUILDING 51DE HALLS. <br />3. IRRIGATION/5PRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE HALL. <br />4. FBG R318.7 - IN ORDER TO PROVIDE FOR INSPEGTION FOR TERMITE INFESTATION, <br />GLEARANGE BETWEEN EXTERIOR WALL GOVERINNS AND FINAL EARTH ORAC7E ON <br />THE EXTERIOR OF A BUILDING HALL NOT BE LE55 THAN 6 INGHES (152 MM) <br />EXGEPTI ON5: <br />I. PAINT OR DEGORATIVE GEMENTITIOU5 FIN15H LE55 THAN g INGH (17.1 MM) THICK <br />ADHERED DIREGTLY TO THE MA50NRY H FOUNDATION 51DENALL. <br />2. AGGE55 OR VEHIGLE RAMPS WHIGH RISE TO THE INTERIOR FINISH FLOOR <br />ELEVATION FOR THE WIDTH OF 5UGH RAMPS ONLY. <br />3. A 4-INGH (102 MM) INSPEGTION SPACE ABOVE PATIO AND GARAGE 5LA65 AND <br />ENTRY AREAS. <br />4. IF THE PATIO HAS BEEN 501L TREATED FOR TERMITES, THE FINISH ELEVATION MAY <br />MATGH THE BUILDING INTERIOR FINISH FLOOR ELEVATIONS ON MASONRY <br />GONSTRUGTION ONLY. <br />5. MASONRY VENEERS GON5TRUGTED IN AGGORDANGE HITH SECTION R30.4. <br />5. R50.1.1 IF SOIL TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL <br />GHEMIGAL SOIL TREATMENT INSIDE THE FOUNDATION PERIMETER SHALL BE <br />DONE AFTER ALL EXCAVATION, BAGKFILLING, AND GOMPAGTION 15 COMPLETE. <br />6. R30.1.2 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 501L <br />AREA DISTURBED AFTER INITIAL GHEMIGAL SOIL TREATMENT SHALL BE RETREATED HITH <br />A GHEMIGAL SOIL TREATMENT INCLUDING SPAGE5 BOXED OR FORMED. <br />T R30.1.3 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 5PAGE IN <br />GONGRETE FLOORS BOXED OUT OR FORMED FOR THE SUBSEQUENT INSTALLATION OF <br />PLUMBING TRAPS, DRAINS OR ANY OTHER PURPOSE SHALL BE CREATED BY U51NO <br />PLASTIC, OR METAL PERMANENTLY PLAGED FORMS OF SUFFIGIENT DEPTH TO ELIMINATE <br />ANY PLANNED SOIL DI5TURBANGE AFTER INITIAL GHEMIGAL SOIL TREATMENT. <br />8. R315.1.4 IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />GHEMIGALLY TREATED SOIL SHALL BE PROTEGTED HITH A MINIMUM 6 MIL VAPOR <br />RETARDER TO PROTEGT AGAINST RAINFALL DILUTION. IF RAINFALL OGGURS BEFORE <br />VAPOR RETARDER PLAGEMENT, RETREATMENT 15 REQUIRED. ANY HORK, INCLUDING <br />PLAGEMENT OF REINFORGING STEEL, DONE AFTER GHEMIGAL TREATMENT UNTIL THE <br />CONCRETE FLOOR 15 POURED, SHALL BE DONE IN SUGH MANNER AS TO AVOID <br />PENETRATING OR DISTURBING TREATED SOIL. <br />q. R318.1.5 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />GONGRETE OVERPOUR OR MORTAR AGGUMULATED ALONG THE EXTERIOR FOUNDATION <br />PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR GHEMIGAL 501L TREATMENT, TO <br />ENHANGE VERTICAL PENETRATION OF THE GHEMIGALS. <br />10. R30.1.6 IF SOIL TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PREVENTION, GHEMIGAL <br />501L TREATMENTS SHALL ALSO BE APPLIED UNDER ALL EXTERIOR GONGRETE OF GRADE <br />HITH I FOOT (505 MM) OF THE PRIMARY 5TRUGTURE 51DEHALLS. ALSO, A VERTICAL <br />GHEMIGAL BARRIER SHALL BE APPLIED PROMPTLY AFTER GON5TRUGTION 15 COMPLETED, <br />INGLUDING INITIAL LANDSGAPING AND IRRIGATION/5PRINKLER INSTALLATION. ANY 501L <br />DISTURBED AFTER THE GHEMIGAL VERTICAL BARRIER 15 APPLIED SHALL BE PROMPTLY <br />RETREATED. <br />II. R318.17 IF A REGISTERED TERMITIGIDE FORMULATED AND REGISTERED AS A BAIT SYSTEM <br />15 USED FOR SUBTERRANEAN TERMITE PREVENTION, 5EGTION 1`230 1.1, THROUGH 5EGTION <br />R30.1.6 DO NOT APPLY; HOHEVER, A SIGNED GONTRAGT ASSURING THE INSTALLATION, <br />MAINTENANGE AND MONITORING OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS <br />FROM THE I55UE OF THE GERTIFIGATE OF OGGUPANGY SHALL BE PROVIDED TO THE <br />BUILDING OFFIGIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE <br />INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />IF THE BAITING SYSTEM DIREGTION5 FOR US REQUIRE A MONITORING PHASE PRIOR TO <br />INSTALLATION OF THE PE5TIGIDE ACTIVE INGREDIENT, THE INSTALLATION OF THE <br />MONITORING PHASE GOMPONENT5 SHALL BE DEEMED TO CONSTITUTE INSTALLATION OF <br />THE SYSTEM. <br />12. R315.1.5 IF A REGISTERED TERMITIGIDE FORMULATED AND REGISTERED AS A HOOD <br />TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SEGTION5 R30.1.1 <br />THROUGH R318.1.6 DO NOT APPLY. APPLICATION OF THE HOOD TREATMENT TERMITIGIDE5 <br />SHALL BE AS REQUIRED BY LABEL DIREGTIONS FOR USE, AND MUST BE GOMPLETED <br />PRIOR TO FINAL BUILDING APPROVAL. <br />13. R315.1 TERMITE PROTEGTION. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED <br />TERMITIGIDE5, INGLUDING SOIL APPLIED PE5TIGIDE5, BAITING SYSTEMS, AND PESTIGIDES <br />APPLIED TO HOOD, OR OTHER APPROVED METHODS OF TERMITE PROTEGTION LABELED <br />FOR USE AS A PREVENTATIVE TREATMENT TO NEN GON5TRUGTION. SEE SEGTION 202, <br />REGISTERED TERMITIGIDE. UPON GOMPLETION OF THE APPLIGATION OF THE TERMITE <br />PROTEGTIVE TREATMENT, A GERTIFIGATE OF GOMPLIANGE SHALL BE 155UED TO THE <br />BUILDING DEPARTMENT BY THE LIGEN5ED PEST GONTROL GOMPANY THAT GONTAIN5 THE <br />FOLLOWIN5 STATEMENT: "THE BUILDIN5 HAS REGEIVED A COMPLETE TREATMENT FOR <br />THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN AGGORDANGE WITH <br />RULES AND LAHS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRIGULTURE AND <br />GON5UMER 5ERVIGE5." <br />14. R315.2 PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING GONGRETE <br />SLAB -ON -GRADE FLOORS SHALL NOT BE OF GELLUL05E-GONTAINING MATERIALS. IF <br />SOIL TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTEGTION, THE SLEEVE SHALL <br />HAVE A MAXIMUM NALL THIGKNE55 OF 0.010 INGH (0.25 MM), AND BE SEALED HITHIN THE <br />SLAB U51N6 A NON-GORROSIVE GLAMPIN6 DEVIGE TO ELIMINATE THE ANNULAR 51PAGE <br />BETNEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 SHALL BE APPLIED IN51DE THE <br />SLEEVE. <br />15. R50.3 GLEANING. GELL5 AND GAVITIE5 IN MASONRY UNITS AND AIR GAPS BETNEEN <br />BRICK, STONE OR MASONRY VENEERS AND THE STRUGTURE SHALL BE GLEANED OF ALL <br />NON -PRESERVATIVE TREATED OR NON -NATURALLY DURABLE WOOD, OR OTHER <br />GELLUL05E-GONTAININ6 MATERIAL PRIOR TO GONGRETE PLAGEMENT. <br />EXCEPTION: INOR6ANIG MATERIAL MANUFAGTURER FOR GLO5ING GELL5 IN FOUNDATION <br />GONGRETE MASONRY UNIT GON5TRUGTION OR GLEAN EARTH FILL PLAGED IN GONGI ETE <br />MA50NRY UNIT VOIDS BELON SLAB LEVEL BEFORE TERMITE TREATMENT IS PERFORMED. <br />4. B .5. SOIL 15 TO BE GOMPAGTED TO q5% MODIFIED PROGTOR AS DEFINED BY ASTM D 1557-12el <br />NOTE: BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. OR <br />SENTRIGON SYSTEM TO BE USED <br />1) METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDIGTION "LIQUID BORATE OR <br />BOR-A-GOR" PRODUGT OR 5ENTRIGON SYSTEM, METHODS MUST BE DETERMINED AT PERMIT STAGE . <br />2) PRESSURE TREATED LUMBER THAT HAS BEEN GUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF <br />HOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT IN5EGT INFESTATION. <br />REOU I RED SAFETY C LAZ I NG IN HAZARDOUS LOGAT IONS <br />SAFETY GLAZING (RE: FRG R308.4) <br />R305.4 HAZARDOUS LOGATION5. THE FOLLOWING SHALL BE GON5IDERED SPEGIFIG HAZARDOUS LOGATIONS <br />FOR THE PURPOSES OF GLAZING: <br />I. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLP DOORS. <br />EXGEPTI ONS: <br />I. GLAZED OPENINGS OF A 5IZE THROUGH WHIGH A 3-INGH DIAMETER Orb mm) <br />SPHERE 15 UNABLE TO PASS. <br />2. DEGORATIVE GLAZING. <br />2. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJAGENT TO A DOOR SHALL BE GON51DERED TO <br />BE A HAZARDOUS LOCATION WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN 60 <br />INGHES (1524 MM) ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING <br />GONDITI ON5: <br />I. WHERE THE GLAZING IS WITHIN 24 INGHES ((910 MM) OF EITHER SIDE OF THE DOOR IN THE PLANE OF <br />THE DOOR IN A GLOSED POSITION. <br />2. WHERE THE GLAZING 15 ON A HALL PERPENDIGULAR TO THE PLANE OF THE DOOR IN A CLOSED <br />POSITION AND HITHIN 24 INGHES (6I0 MM) OF THE HINGE SIDE OF AN IN-51^1INSINS DOOR. <br />EXGEPTI ON5: <br />I. DEGORATIVE GLAZING. <br />2. HHERE THERE 15 AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETNEEN THE DOOR AND THE <br />GLAZING. <br />3. HHERE AGGE55 THROUGH THE DOOR 15 TO A GLO5ET OR STORAGE AREA 3 FEET (c114 MM) OR LE55 IN <br />DEPTH. GLAZING IN THIS APPLICATION SHALL GOMPLY HITH 5EGTION R308.4.3. <br />4. GLAZING THAT 15 ADJAGENT TO THE FIXED PANEL OF PATIO DOORS <br />3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE WINDOH THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />I. THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN q SQUARE FEET (0.536m2); AND <br />2. THE BOTTOM EDGE OF THE GLAZING IS LE55 THAN IS INGHES (457 mm) ABOVE THE FLOOR; AND <br />3. THE TOP EDGE OF THE GLAZING 15 MORE THAN 36 INGHES (q14 mm) ABOVE THE FLOOR; AND <br />4. ONE OR MORE HALKING 5URFAGE ARE HITHIN 36 INGHES (q14 mm), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, OF THE GLAZING. <br />EXGEPTI ONS: <br />I. DEGORATIVE GLAZING. <br />2. WHEN A HORIZONTAL RAIL IS INSTALLED ON THE AGGESSIBLE SIDE(5) OF <br />THE GLAZING 34 TO 3& INGHES (546 TO q65) ABOVE THE HALKING <br />5URFAGE. THE RAIL SHALL BE CAPABLE OF NITHSTANDING A HORIZONTAL <br />LOAD OF 50 POUNDS PER LINEAR FOOT (730 N/m) NITHOUT GONTAGTING <br />THE GLASS AND BE A MINIMUM OF 1 1/2" INGHES (55 mm) IN GROSS 5EGTIONAL HEIGHT. <br />3. OUTBOARD PANES IN INSULATING OLA55 UNITS AND OTHER MULTIPLE GLAZED PANELS WHEN THE <br />BOTTOM EDGE OF THE 6LAS5 15 25 FEET (7620 mm) OR MORE ABOVE GRADE, A ROOF, HALKING <br />5URFAGE5 OR OTHER HORIZONTAL (HITHIN 45 DEGREES (O.q7 RAD) OR HORIZONTAL) SURFACE <br />ADJAGENT TO THE OLA55 EXTERIOR. <br />4. ALL GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A HALKING 5URFAGE. INGLUDED ARE <br />5TRUGTURAL BALUSTER PANELS AND NON5TRUGTURAL INFILL PANELS. <br />5. GLAZING IN HALLS, ENGLO5URE5 OR FENGE5 CONTAINING OR FAGING HOT TUBS, SPAS, WHIRLPOOLS, <br />SAUNAS, STEAM ROOMS, BATHTU55, 5HOHER5 AND INDOOR OR OUTDOOR SHIMMING POOLS HHERE THE <br />BOTTOM EXP05ED EDGE OF THE GLAZING IS LE55 THAN 60 INGHES (1524 MM) MEASURED VERTICALLY <br />ABOVE ANY STANDING OR HALKING 5URFAGE SHALL BE CONSIDERED TO BE A HAZARDOUS LOGATION. <br />THIS SHALL APPLY TO SINGLE GLAZING AND EAGH PANE IN MULTIPLE GLAZING. <br />EXCEPTION: GLAZING THAT IS MORE THAN 60 INGHES (1524 MM), MEASURED HORIZONTALLY AND IN A <br />STRAIGHT LINE, FROM THE HATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SWIMMING POOL OR <br />FROM THE EDGE OF A 5HOHER, SAUNA OR STEAM ROOM. <br />(q. GLAZING WHERE THE BOTTOM EXP05ED EDGE OF THE GLAZING 15 LESS THAN 36 INGHES N14 MM) ABOVE <br />THE PLANE OF THE ADJAGENT HALKING 5URFAGE OF 5TAIRHAY5, LANDINGS BETNEEN FLIGHTS OF 5TAIR5 <br />AND RAMPS SHALL BE GON5IDERED TO BE A HAZARDOUS LOGATION. <br />EXGEPTI ONS: <br />I. HHERE A RAIL IS INSTALLED ON THE AGGESSIBLE 51DE(5) OF THE GLAZING 34 TO 3B INGHES (864 TO <br />q65 MM) ABOVE THE WALKING 5URFAGE. THE RAIL SHALL BE GAPABLE OF HITH5TANDING A <br />HORIZONTAL LOAD OF 50 POUNDS PER LINEAR FOOT (730 N/M) HITHOUT GONTAGTIN5 THE GLA55 AND <br />HAVE A GRO55-5ECTIONAL HEIGHT OF NOT LESS THAN 1 1/2 INGHES (38 MM). <br />2. GLAZING 36 INGHES NA MM) OR MORE MEASURED HORIZONTALLY FROM THE NALKINS SURFACE. <br />7. GLAZING ADJAGENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE SLAZIN6 IS LESS THAN <br />36 INGHES M14 MM) ABOVE THE LANDING AND HITHIN A 60-INGH (1524 MM) HORIZONTAL ARG LE55 THAN <br />180 DEGREES FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. <br />EXCEPTION: THE GLAZING IS PROTEGTED BY A GUARD COMPLYING HITH 5EGTION R512 AND THE PLANE OF <br />THE GLA55 15 MORE THAN 0 INGHES (457 MM) FROM THE GUARD. <br />NOTE: <br />IT 15 THE GONTRAGTORS RESPONSIBILITY TO REVIEW ALL PRANIN65 BEFORE GON5TRUCTION BEGINS. <br />DAN5GO ENGINEERING, LLC, 15 RESPONSIBLE FOR THE 5TRUGTURAL INTEGRITY OF THIS PROJECT ONLY. ANY <br />D15GREPANGY BETWEEN FIELD GONDITION5, OTHER DE510N PROFE5510NAL5' SHOP DRAHIN65, <br />GONTRAGTOR5' BUILDING METHODS, AND THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE <br />ATTENTION OF FLORIDA DESIGN SOLUTIONS, ING. PRIOR TO THE GOMMENGEMENT OF GON5TRUGTION. <br />ATTENTION: GHEMIGAL GHANGES IN PRESSURE TREATED WOODS <br />AS OF DEGEMBER 315T, 2003, GHROMATED COPPER ARSENATE (GGA-G) HILL NO LONGER BE PRODUGED FOR <br />RESIDENTIAL OR GENERAL CONSUMER USE SEVERAL NEW PRESSURE TREATED HOOD ALTERNATIVES HAVE <br />BEEN GREATED TO REPLAGE GGA-G. MANY OF THE NEW PRESSURE TREATED WOODS USE GHEMIGALS THAT <br />ARE GORRO51VE TO STEEL. IT 15 THE GONTRAGTOR'5 RESPONSIBILITY TO VERIFY THE TYPE OF HOOD <br />TREATMENT AND TO 5ELEGT APPROPRIATE GONNEGTOR5 THAT RESIST GORROSION. FOR EXAMPLE, AGO-G, <br />AGO-0, GBA-A, OR GA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM <br />BORATE (SBX) DOES NOT. <br />NORST GASE DES I ON PRESSURE TABLE <br />BUILDING DATA <br />WIND SPEED 140 MPH (Vasd 108 MPH) <br />WIND EXPOSURE -- 'C' (FRC R301) <br />INTERNAL PRESSURE COEFFICIENT= +/- 0.18 ENCLOSED BLDG) <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />0 END ZONE IS ONLY WITHIN 5'-O' <br />OF ALL EXTERIOR BUILDING CORNERS <br />WINDOWS AND DOORS (ASD PRESSURES) <br />140 MPH + 25b PSF / - 343 PSF (END) UNLESS NOTED ON FLOOR PLANS <br />+ 25.6 PSF / - 21.1 PSF ( INTERIOR) UNLESS NOTED ON FLOOR PLANS <br />GARAGE DOORS (ASD PRESSURES) <br />SINGLE 130 + 223 PSF / - 253 PSF <br />DOUBLE 16x-I + 21.4 PSF / - 23.8 PSF <br />':: �'ziai:.r.F�.:s,:.�a^?ow.tiYS..,%• <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineering.com <br />CA 25948 <br />O <br />O <br />N <br />Z Lu <br />O�^ <br />O <br />tD <br />z <br />CD <br />p(AMN <br />LL <br />Q N J Ln <br />W aLL^ <br />z <br />IQ-aar'� <br />00 <br />00 <br />Z �j3 Q <br />W <br />W� <br />J <br />O <br />J%D <br />d' <br />U <br />u4) Lu Lu <br />Lu <br />W � C/) <br />O V) <br />Q m <br />V) W <br />Q O °° <br />co <br />O <br />w <br />Z U <br />F_ Z � <br />O <br />t) M <br />U <br />C <br />V) <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = 108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = 30.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />©M19 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER W1rHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019 -THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CUENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 <br />1.02 ROOF UNDERLAYMENT REV. <br />02.11.19 <br />1.03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERS19,�0 40. 1,.03 /.02 1,1.19 <br />07 <br />c� <br />c� <br />CL <br />0 <br />rxLLJ O <br />cc J <br />z O <br />�i Lu <br />W } 3 <br />CieQN 2N _3� <br />W wM =10 �Do <br />Lu �* }* W* <br />Z <br />Q LLI = LLI � LLI <br />W ❑ Lam_ ❑ <br />SHEET TITLE: <br />STRUCTURAL NOTES <br />SHEET INFORMATION: <br />JOB NO.: 390443 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />SN <br />i�-rli :u oT�Lllnic:-. <br />