Laserfiche WebLink
' o <br />n <br />----------------------------`- <br />L---------1------------- <br />(V <br />V-0' RIDGE VENTRIDGE4'-0'RIDGEVENTL4�`�� <br /><PE <br />\ <br />RV 1 <br />z <br />I <br />I <br />I <br />� <br />RIDGE <br />I <br />SLOPE 5:12 <br />SLOPE 5:12 _ <br />I <br />1 <br />I <br />I <br />I <br />LU <br />I <br />� <br />I <br />I <br />1 <br />I _ <br />I z <br />UIA <br />w <br />z <br />n <br />t <br />J <br />I D� <br />cx > <br />> <br />o <br />I <br />--- <br />— <br />4'-0' <br />(TYPJ <br />PF -RIDGEVENT LIA 0- <br />RV 2 <br />NOTE: � <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF ROOF FLAT I � <br />INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF <br />SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. SCALP: 3116'=i'-0' <br />Co � LU <br />> _QL <br />SLOPE 5:12 _ <br />Ji <br />0 <br />O ROOF VENT 5CNEDULE O <br />Verify with General Contractor all roof vent locations, <br />quantities, and sizes. Roof vents shall be installed <br />for a minimum of vented area as listed below or <br />equivalent system per 6TIH EDITION (2011) FRC, R8062. <br />Mark <br />Location <br />Roof vents or <br />equal system (sq. in.) <br />Soffit Vent <br />(sq. in.) <br />RV i <br />2nd Level <br />Roof <br />412 <br />412 <br />RV 2 <br />Ist Level <br />Front Roof <br />27 <br />2i <br />RV 3 <br />Ist Level <br />Gara a Roof <br />56 <br />56 <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE 15 NO <br />ACCESS TO EXTERIOR THROUGH A DOOR THE <br />WINDOW MUST HAVE A MAXIMUM SILL HEIGHT OF <br />44' MEASURED FROM THE FINISHED FLOOR OF <br />THAT PARTICULAR ROOM TO THE 130TTOM OF <br />THE CLEAR OPENING. <br />* * * * <br />STUCCO FINISH <br />4' 5CORED RAKE <br />ROOF SHINGLES PER SPEC'S <br />STUCCO FIN15H <br />SEE12 <br />'-3'-2"NEE=L NC T. PLAN SEE PLAN FOR <br />TRUSSES <br />&' -V BRG- N4GT. OLF. FLOOR ELEV. 0'-0' <br />LU <br />fL <br />Q <br />2x FRAMING AS REQ <br />2x4 (TYP) <br />SEE PLANS FOR SEAM SIZE m <br />(2) 2x4 FRAMING <br />STUCCO FINISH OVER <br />MTL. LATHE 414(o' OSS <br />SHEATHING 4 FRAMING `r <br />AS REQUIRED �r TRUSSES PER PLANS <br />SEE PLANS FOR P05T SIZE <br />P05T TO CMU CONNECTOR 5EE FAN <br />REFER TO PLANS <br />2x4 SILL FRAMING 1/2 WALL OR RAILING <br />iA (TYP) <br />2x6 (TYP.) <br />STUCCO FINISH 2xs WALL STAIR <br />MA50NRY WALL <br />SEE FOUNDATION PLANS <br />FOR FOOTER SIZE <br />0'-0" PIN, PLR.71] <br />F31 <br />SEE SHEET 1 FOR V MATERIAL INFO <br />—12 <br />51}, <br />THIGM55 OF TEXTURED FINISH OVER <br />' FRAM APPLICATION TO BE PER <br />FRC R1031 <br />NOTE: <br />,: - DIMENSION MEASURES FROM THE <br />LOWEST PART OF THE CLEAR OPENING <br />OF THE WINDOW TO THE 2ND FINISH FLOOR <br />12 <br />5 <br />F26 <br />'STUCCO FINISH <br />F28' ' F5 . <br />ISSUANCE OF PLANS FROM THIS DESIGNERS OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE <br />BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE FOR CORRECTION BEFORE <br />COMMENCEMENT OF ANY CONSTRICTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. <br />F ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE <br />DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />F23 <br />SHINGLE ROOF <br />PER SPEC'S <br />12 <br />'� 5 <br />RIDGE VENT 12 12 <br />SHINGLE ROOF PER SPECS. 5� ® 12 RIDGE VENT 5 <br />12 OFF -RIDGE VENT J 12 12 <br />5� SHINGLE ROOF PER SPECS. 5 5 <br />,,T, PLATE ELEV. is' -I 1/8' <br />*- STUCCO FINISH 12 <br />OFF RIDGE VENT —� STUCCO FINISH r <br />F. FLOOR ELEV. i6-0 3/4' <br />T. BLOCK ELEV. V-8' _ <br />— — — — — EXP. JT. LINE — — — �EXP. JT. LINE <br />- LIGHT TEXTURE SEE 3/48 FOR <br />LIGHT TEXTURE <br />DECO. FINISH /� DECO. FINISH <br />�,- COLUMN DETAIL � 3-0� F23 <br />T <br />F. FLOOR ELEV. <br />12 <br />SCALP: I/S'=1'-0' SCALP: I/S'=1'-0' <br />12 12 12 <br />ROOF TSES �5 5� �5 RIDGE VENT <br />5 RUS <br />PER PLANS SHINGLE ROOF PER SPECS. <br />T. PLATE ELEV. I5-1 <br />AEG <br />""',BATH - To TRUSSED PER PLAN STUCCO FIN15H <br />E7 12 5 F. FLOOR ELEV.10'-0 3/4' <br />T. BLOCK ELEV. 8'1 <br />— — — — <br />FLOOR SYSTEM MA50NRY WALL EXP, JT, LINE 12 <br />1/2 WALL OR RAILING LIGHT TEXiURE t 35 <br />DECO. FINISH 0, <br />jFAMILO <br />2x4 WALL GARAGE MOM: 12- <br />F23 <br />F. FLOOR ELEV. 6-0' <br />SCALP: I/8'=1'-0' <br />SCALE: 1/8'=I'-0' <br />T� <br />,,�yg Via': ;•.y``•`\••,`jay,�' �'% ss .�Y <br />ui <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineedng.com <br />CA 25948 <br />o <br />CD <br />N <br />Z w <br />O <br />o^ <br />M <br />Z <br />M COD <br />Q � J � <br />�ww� <br />ZFa-'aaM <br />a�a00 <br />WLU <br />Z LU <br />J 3: <br />O <br />O <br />LU <br />1211::� m W <br />V ^p <br />Q <br />HZ <br />,V) <br />/ v I <br />LU <br />LU I - J <br />LJJ U m <br />Q Lu LU <br />(� w m <br />Q Q O <br />U � v <br />o00• <br />N Q r- <br />W <br />cU �O <br />Q <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd=108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IF IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWING ONLY. <br />® 2019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019-THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />12.13.17 <br />1.00 6TH ED. (2017) FBC <br />UPDATES <br />12.29.17 <br />1.01 PLAN REVISIONS TO HVAC <br />SPACE & ELECTRICAL <br />04.30.18 <br />1.02 REV. FLOOR TURSS LAYOUT <br />02.07.19 <br />1.03 USE SIMPSONH10ILO <br />USP RT16A <br />VERSION NO. T.03`/ 02A7,19 <br />Ir <br />J' t <br />Q_ <br />O <br />w <br />m <br />z O <br />Q = U <br />W U' ZN _ <br />h Q� =N A04 <br />LUw _� <br />:20 <br />LUw <br />Z <br />QLLl =Lj NLLi <br />C <br />2 <br />to a_ T— a- a- <br />❑ ❑ <br />W <br />SHEET TITLE: <br />ELEVATION "B" EXTERIOR <br />ELEVATIONS & ROOF PLAN <br />SHEET INFORMATION: <br />JOB NO.: 390443 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: JH <br />REVIEWED BY: TH <br />46 <br />r— <br />01-1 <br />O <br />I <br />1 <br />00 <br />04 <br />L0 <br />rl— <br />