OPTIONAL OVERHEAD SERVICE SAME AS <br />UNDERGROUND 150 OR 200 AMP SERVICE <br />REFER TO FLOOR PLAN FOR <br />NOTED AMPS, REQUIRED <br />UNDERGROUND SERVICE <br />BY POWER COMPANY <br />150 = »I COPPER OR 2/0 ALUMINUM <br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT. <br />"12 COPPER TO APPLIANCES AND GFI <br />14 COPPER TO LIGHTS AND OUTLETS <br />MO COPPER TO WATER HEATER <br />18 COPPER TO RANGE <br />06 COPPER TO HVAC <br />TOP RAILING <br />NOTE: SUBFLOOR ADHESIVE IS USED IN ADDITION <br />BALUSTERS TO NAILS ON WOOD COMPONENTS, <br />MAX SPACING 4" <br />1 X 8 PAINTED IUD. CAP STRINGER IS LAMINATED TO A THICKNESS EQUIVALENT TO <br />OGEE STOP THE SIZE OF A 2 X 12 S.Y.P. AND IS NAILED TO EACH <br />TREAD W/ 16d NAILS FROM THIRD LAMINATE TO TREAD- <br />OPT, 2 X 2 BLOCKING NAILED <br />TO TREAD AND RISER, <br />04 GROUNDING WIRE WITH CODE I <br />APPROVED CLAMP PER 250.50 17 <br />3-2 X 12 STRINGER 2 X BLOCKING NAILED TO STRINGER, <br />AND 250.52 OF THE 2014 NEC. ]][�� � o <br />M 3/4" RISERS RISER, AND TREAD. <br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 250.94 <br />ELECTRICAL RISER DIAGRAM - <br />NOTE: <br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS <br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/`UTILITY COMPANY <br />5TAIR NOTE5 <br />RAILING <br />BALUSTERS SHALL BE SPACED SO THAT A 4" SPHERE CANNOT PA55 THROUGH. <br />HANDRAILS <br />HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR <br />SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS. <br />CONTINUOUS GRASPABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER -STAIR PROTECTION <br />ENCLOSED ACCE551BLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACE AND ANY SOFFIT PROTECTED ON THE <br />ENCLOSED SIDE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11 <br />5TAIRWALL FRAME NOTE <br />ALL STAIRWELL SURROUNDING WALLS AND KNEE WALLS ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD <br />OCCUPANCY AND CON5TRUCTION TYPE: <br />THIS UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-B CLASSIFICATION. <br />CEILING CONSTRUCTION: <br />I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED <br />TO THE GARAGE SIDE, GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HA ITABLE ROOMS ABOVE BY NOT LESS THAN <br />5/8 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE <br />SUPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LESS THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT. <br />DWELLING / GARAGE OPENING5: <br />I. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LESS THAN 1 3/8" IN THICKNESS, <br />SOLID CORE (S.C.) OR HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1 3/5" THICK, OR 20 MINUTE FIRE RATED DOORS, <br />2, ALL DOORS FROM GARAGE ADJACENT TO LIVING SPACE MUST BE EITHER A 50LID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTES. <br />EGRE55: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCESS TO EXTERIOR THROUGH A DOOR. THE <br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR ROOM, <br />WINDOW IN5TALLATION: <br />WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN <br />INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. <br />TERMITE PROTECTION: <br />I. PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE <br />CONTAINING MATERIALS. IF SOIL TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL <br />THICKNE55 OF 0.010 INCH, AND BE SEALED WITHIN THE SLAB USING A NON -CORROSIVE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE <br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDE5 SHALL BE APPLIED INSIDE THE SLEEVE. <br />2. PROTECTION AGAINST DECAY AND TERMITES. - CONDENSATE LINES, IRRIGATION / SPRINKLER SYSTEM RISERS FOR SPRAY HEADS, AND ROOF <br />DOWNSPOUTS SHALL DISCHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTENSIONS, OR SPLASH BLOCKS. GUTTERS WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. <br />2 X TREADS± RIP FROM 2x12 <br />TO SIZE NOTED ON PLAN <br />TYP. OPT. RAILING ELEVATION <br />SCALE: 1/2" = 1411 <br />NEWEL P05T <br />TOP RAILING <br />BALUSTER 4" O.C. <br />SHOE RAIL (REMOVE <br />W/ METAL SPINDLES) <br />I X 8 PAINTED WD. CAP <br />OGEE STOP <br />r QUK LINt _ <br />OPTIONAL <br />,, RAILING DETAIL <br />SCALE. I - I 0 <br />I X SPRUCE "3 OR 3/4" CDX. <br />PLYWD, RISER. <br />2 X SOUTHERN YELLOW PINE $1 <br />(ACTUAL THICKNESS IS 1 1/2") TREAD, <br />CLOSED RISER DETAIL <br />SCALE: 1/2" = 1'-0" <br />CARP[ <br />CARP[ <br />TREAC <br />RISER <br />2X4WALL <br />1/2" GYP BD. <br />3/4" SKIRT BD. <br />2 X 4 SPACER <br />2X12 <br />STRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B SCALE: 3/4" : I4" <br />GENERAL CONSTRUCTION NOTES <br />CHAPTERS AND SECTIONS REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011) <br />MECHANICAL AND HVAC: <br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO <br />TH15 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, <br />REPAIRED, OR REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30 INCHES (162 mm) WIDE SHALL BE PROVIDED IN <br />FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE <br />CONSTRUCTED OF A MIN. "26 GAUGE (0,48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (1(o mm) ABOVE THE FINISHED <br />GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF 5ECTION5 M14113, <br />EXHAU5T FAN5 AND VENTING <br />1.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL <br />NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND <br />SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, <br />CRAWL SPACE, OR OTHER AREAS INSIDE THE BUILDING, <br />3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAID) BEND <br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (Ilo RAD) BEND, THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE <br />LABEL SHALL BEAR THE WORDS "TH15 DRYER EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." <br />4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH <br />AMIGA STANDARD 550 IN FBC. <br />ROUGH- IN INSPECTION REQUE5T NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE <br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE <br />FRAMING INSPECTION. <br />WINDOW FALL PROTECTION <br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS <br />LOCATED MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR <br />SURFACE BELOW, THE LOUDEST PART OF THE CLEAR OPENING OF THE <br />WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED, OPERABLE <br />SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW <br />PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER F.B.C. <br />RESIDENTIAL 6th EDITION (2011) - SECTION R312.2. <br />WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE <br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENTS OF ASTM F 2090 <br />PER F.B.C. RESIDENTIAL bth EDITION (2011) - SECTION R312.2. <br />IN5ULATION NOTE5 <br />• CMU WALLS:----- R-FOIL 4.1 • KNEE WALLS THAT <br />BACK UP TO CEILING <br />• FRAME WALLS:-------- R-13 AREA ONLY:----------- R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URVEY NOTE <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE <br />SURVEY SHALL BE ON THE 51TE FOR THE BUILDING INSPECTOR'S USE, <br />OR ALL PROPERTY MARKERS SHALL BE EXP05ED AND A STRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />SETBACKS. <br />CELING AT ENTRY NOTE <br />ALL ENTRY CLGS. TO BE 15/32 05B. CEMENTITOUS FINISH (UN.0) <br />G45 APPLIANCE PROTECTION IN GARAGE NOTE <br />PROTECTION OF GAS APPLIANCES IN RESIDENTIAL GARAGES: <br />MINIMUM 3" DIAMETER SCH 40 STEEL PIPE, 2 FT. BELOW CONCRETE <br />SLAB AND 3 FT. ABOVE FINISHED FLOOR. <br />GENERAL NOTE5 <br />• DUE TO VARIATIONS IN CITY REQUIREMENTS, SUBDIVISION <br />SPECIFICATIONS, CONSTRUCTION TECHNIQUES, DIVERSITY IN <br />MATERIALS, AND PLAN REVISIONS, ALL DIMENSIONS AND <br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN, ACTUAL FIELD <br />CONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE <br />PROCEEDING WITH CONSTRUCTION. <br />• ELECTRICAL LOCATIONS SHOWN ON DRAWINGS MAY BE CHANGED <br />AT THE SOLE DISCRETION OF CALATLANTIC HOMES OR ITS <br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODES. CALATLANTIC <br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLETS <br />AND / OR SWITCHES SHOWN. <br />• ALL PLUMBING DIMENSIONS ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR SLAB EDGE. IT IS THE <br />RESPONSIBILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMENSIONS. <br />NOTE: ANY DIMENSIONS AND/OR CALLOUT5 WITHIN TH15 SET OF DRAWINGS REFERENCING <br />LUMBER SIZES OR WALL THICKNESSES ARE TO BE CONSIDERED "NOMINAL DIMENSIONS" <br />CHIMNEY HEIGHT REQUIREMENT5: <br />WHEN STANDARD OR OPTIONAL FIREPLACE IS TO BE INSTALLED THE CHIMNEY MUST EXTEND Y-0" PAST THE HIGHER POINT WHERE IT <br />EXTENDS THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'-0" AWAY OR CLOSER. <br />TUB AND SHOWER AREA5: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1286, GI325, OR CI118 <br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND <br />SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS. <br />FLOOD ZONE REQUIREMENT5: <br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION, <br />DAVIS BEWS <br />DESIGN GROUP <br />�.so sr�`rE STREET Fi�.sr <br />of os�n�, r�.oRro� a��n <br />813 . 925 . L300 TFL <br />813. was . isoo FAX <br />W W W.D.'�VISBEWS.COM <br />TAMPA • DELAYER. <br />-�=� FST.1994 �ti-�-- <br />0 <br />Z N <br />O °r o <br />� M O <br />j M Ln <br />gQoLn <br />Q a� <br />M <br />z < E <br />U o- 00 <br />Z��`. <br />w <br />wo <br />J o <br />�o <br />�o <br />w� <br />z0. <br />Q� <br />'^ OQQ,o <br />�zz <br />I-1 o W z <br />J <br />OLu <br />celLL0 <br />W o� <br />0 zo <br />av <br />r zZ <br />z Z <br />O Q <br />H <br />Z <br />oQ <br />.~� UJ <br />z Q�W <br />z <br />z U z zo <br />J 0 <br />Lu z I z <br />0 <br />z a L 0 <br />co z <br />° g w �m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />iso <br />SHEET NO. <br />DT1 <br />