Laserfiche WebLink
SPED I F I GATT ONS <br />I. I. CONSTRUCTION <br />I. I. I. AGI 3 b-05 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. I. 2. AGI 530-05, A50E 5/TM5 402-05 d AGI 530.1-05, A5GE 6/TMS 602-05 <br />SPECIFICATIONS FOR MASONRY 5TRUGTURE5. <br />I. I. 3. A5TM G210-04, G416-02, AND Gq0-OI SPECIFICATIONS FOR MASONRY STRUCTURES <br />I. I. 4. NATIONAL DE516N 5PECIFIGATION5 (NDS) FOR WOOD GON5TRUGTION, 2005 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />I. I. 5. FLORIDA RESIDENTIAL CODE (FRG), FLORIDA BUILDING CODE (FBG), 2001 EDITION, <br />(INGLUDING 200q SUPPLEMENT) <br />I. 1. 6. "MANUAL OF STEEL GON5TRUGTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION, (AI5G) CITH EDITION. <br />I. I. 1. "DESIGN SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />TRU55 PLATE INSTITUTE TPI 1-02. <br />I. I. b. FLORIDA FIRE PREVENTION CODE (FFPG 2001) <br />1.2. DESIGN : <br />I. 2. I. <br />AGI 30-05 BUILDING CODE REQUIREMENT5 FOR 5TRUGTURAL CONCRETE <br />I. 2. 2. <br />AGI 550-05, ASGE 5/TM5 402-05 d AGI 550.1-05, A5GE 6/TM5 602-05 <br />SPECIFICATIONS FOR MA50NRY STRUCTURES. <br />I. 2. 3. <br />- 4 - A 4 - I SPECIFICATIONS FOR MASONRY TRUCTURE5 <br />A5TM G210 04, G 16 02, AND G O O S E 50 5 <br />I. 2. 4. <br />NATIONAL DESIGN 5PEGIFIGATION5 (NDS) FOR WOOD GON5TRUGTION, 2005 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />I. 2. 5. <br />PLYWOOD DE51ON 5PEGIFIGATION5 (APA) <br />I. 2. 6. <br />FLORIDA RESIDENTIAL GODE (FRG), FLORIDA BUILDING CODE (FBG), 2001 EDITION, <br />(INCLUDING 200q SUPPLEMENT) <br />1.5. SHOP <br />DRAWINGS : <br />I. 3. 1. <br />THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DE51ON PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP DRAWIN65 WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />I. 3. 2. <br />ALL SHOP DRAWIN65 ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE COMMENCEMENT OF GON5TRUGTION. <br />I. 3. 3. <br />ALL ROOF AND FLOOR TRU55 SHOP DRAWIN65 ARE TO BE SIGNED AND SEALED BY A <br />FLA. RE6. PE. AND SHALL INCLUDE: DRAWIN65 AND CALCULATIONS, REACTIONS AND <br />BEARING POINTS, BRACING REQUIREMENTS, AND CONNECTIONS TO <br />SUPPORTING TRUSS MEMBERS. <br />1.4. GENERAL BUILDING NOTES <br />I. 4. I. <br />OGGUPANGY CLA551FIGATON RESIDENTIAL, GROUP R-3 <br />I. 4. 2. <br />BUILDING HEIGHT IN FEET d NUMBER OF STORIES = < 60'-0", 2-STORY <br />I. 4. 3. <br />TYPE OF CONSTRUCTION: VB <br />I. 4. 4. <br />PARTY HALLS SHALL PROVIDE NOT LESS THAN A 2-HOUR FIRE RESISTANCE RATING. <br />PLUMBING, PIPING, DUCTS ELECTRICAL OR OTHER BUILDING SERVIGE5 SHALL NOT BE <br />INSTALLED WITHIN OR THROUGH THE 2-HOUR WALL UNLESS 51JCH MATERIALS AND METHODS <br />OF PENETRATION HAVE BEEN TESTED IN ACCORDANCE WITH FBG 2001, SECTION 103. <br />2. DES I GN LOADS <br />2.1. DEAD <br />LOADS: <br />2. I. I. <br />UNIT HEIGHT OF SOIL, COMPACTED : 120 PGF <br />2. I. 2. <br />UNIT HEIGHT OF REINFORCED CONCRETE : 150 PGF <br />2. 1.5. <br />UNIT WEIGHT OF b" G.M.U. BLOCK 55 PSF <br />2. I. 4. <br />15T FLOOR 50PERIMP05ED LOAD : 20 P5F <br />2. 1.5. <br />UNIT HE16HT OF 2x4 PARTITION HALLS : II PSF <br />2. I. 6. <br />UNIT HEIGHT OF 2x6 BEARING WALLS : 12 P5F <br />2. I. 1. <br />BALCONIES d DECKS : 15 P5F <br />2. I. 8. <br />TILE ROOF <br />TOP CHORD : 15 P5F <br />BOTTOM CHORD : 10 P5F <br />2. I. q. <br />SHINGLE ROOF <br />TOP CHORD 1 P5F <br />BOTTOM GHORD : 10 P5F <br />2. I. 10. <br />FLOOR TRU55E5 15 <br />2.2. <br />LIVE <br />LOADS : <br />2. 2. I. <br />51DEHALK AND DRIVEWAY LOAD: 250 PSF <br />2. 2. 2. <br />GARAGE LOADS; 40 PSF <br />2. 2. 3. <br />PARTITIONED ROOMS: 40 PSF <br />2. 2. 4. <br />BALCONY AND DECKS : 60 P5F <br />2. 2. 5. <br />5TAIRWAY5 AND LANDINGS : 40 P5F <br />2. 2. 6. <br />2. 2.1. <br />FLOOR TRUSS <br />TOP CHORD MINIMUM : 40 PSF <br />2. 2. 8. <br />ROOF TRUSS <br />TOP CHORD MINIMUM 20 P5F <br />BOTTOM GHORD (H/O STORAGE) 10 P5F (NON -CONCURRENT) <br />2 3 <br />RAILING LOADS : <br />2. 3. 1. <br />ALL RAILING AND GUARD RAIL 5Y5TEM'5 ARE TO BE DESIGNED TO HITHSTAND A <br />CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY <br />DIRECTION ON THE RAILING. <br />2. 3. 2. <br />ALL RAILING AND GUARD RAIL 5Y5TEM'S ARE TO BE DESIGNED TO WITHSTAND A <br />HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD <br />OF 100 PLF APPLIED VERTICALLY DOWNWARD AT THE TOP OF THE GUARDRAIL <br />2. 3. 3. <br />GUARDRAIL SYSTEM SHALL BE DE516NED TO WITHSTAND 2001b CONCENTRATED <br />HORIZONTAL LOAD APPLIED ON 1 50. FT. AT ANY POINT IN THE SYSTEM. <br />2. 3. 4. <br />2.3.1., 2.3.2 d 2.3.3. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH <br />SHALL BE APPLIED TO PRODUCE THE MAXIMUM 5TRE55E5 IN THE MEMBER GOMPONENT5. <br />2.4. <br />HI ND <br />LOADS : <br />2. 4. I. <br />HIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH SEGT. R501 OF THE FRG 2001 <br />EDITION (INCLUDING 200q SUPPLEMENT), AND CONDUCTED BASED ON A 120 MPH, 3 <br />SECOND &U5T, EXPOSURE "C", IMPORTANCE FACTOR "I" = I.O. ENCLOSED BUILDING <br />2. 4. 2. <br />NET UPLIFT DEAD LOADS - 10 P5F SHINGLE, 15 P5F TILE <br />2. 4. 3. <br />WIND LOAD DETERMINATION BASED ON ASGE 1-05 <br />2.5. <br />DEFLECTIONS : <br />FLOOR TRUSSES SHALL LIMIT DEFLECTION TO 1/560 TIMES THE SPAN FOR LIVE LOADS <br />ND /240 TIMES THE SPAN FOR TOTAL LOAD. <br />3. DESIGN <br />M THOD <br />3. I. <br />LOAD FACTOR DESIGN <br />3. I. I. <br />THE LOAD FACTOR DESIGN METHOD WAS USED TO DE510N <br />GA5T-IN-PLAGE CONCRETE 5LA55 AND FOOTIN05 <br />3 2. <br />SERVICE LOAD DESIGN : <br />3. 2. I. THE SERVICE LOAD DE51ON METHOD HAS USED TO DE51ON <br />MASONRY WALLS AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING <br />STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UPLIFT <br />3 3 LOAD COMBINATIONS FOR LRFD DESIGNS <br />3. 3. I. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR <br />TOTAL DL + FLOOR LL + ROOF LL <br />TOTAL DL + FLOOR LL + HL <br />TOTAL DL + HL <br />3. 3. 2. ALL ROOF AND FLOOR TRUSSES SHALL BE DE51ONED TO RE515T THE HOR5T LOAD <br />COMBINATION RESULTING IN THE MAXIMUM STRE55ES PLACED ON THAT COMPONENT. <br />BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. <br />3 4. DESIGN ASSUMPTIONS : <br />3. 4. I. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS <br />SHOWN OTHERWISE IN THE DE51ON PLANS. <br />4. MATERIALS <br />4. 1. RE I NFORG I NG STEEL <br />4. I. I. REINFORCING STEEL SHALL BE A5TM A615-04a GRADE 40, f'y = 40 Ksi <br />4. I. 2. LAP SPLICE SHALL BE A5 FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 15". <br />4, 1.3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE <br />CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION 15 SHOWN TO THE <br />FACE OF THE CONCRETE. <br />4. 1.4. REINFORCING PETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. 1.5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF <br />RECORD. <br />4. 1.6. DE51ON COVER REQUIREMENT5 <br />G-I-P CONCRETE FORMED AGAINST EARTH 31, <br />C-I-P CONCRETE EXPOSED TO EXTERIOR : 2" <br />G-I-P CONCRETE NOT EXPOSED : IY211 <br />GROUT FILLED MASONRY : 314 <br />4. I. 1. WELDED WIRE FABRIC (WWF): A5TM A05-01 <br />4. I. 8. DETAIL REINFORCEMENT IN ACCORDANCE WITH AGI 315-LATE5T EDITION. <br />4.2. CONCRETE : <br />4.2.1. <br />CONCRETE TYPE <br />MIN. 25 DAY <br />DE51ON (Fc.) <br />MODULES OF <br />ELASTICITY <br />DESIGN (E) <br />G-I-P CONCRETE (NORMAL HEIGHT) <br />2,500 Psi <br />2,550 Ksi <br />G-I-P CONCRETE (NORMAL HEIGHT) HERNANDO GO. ONLY <br />5,000 Psi <br />5,122 Ksi <br />G-I-P GROUT <br />3,000 Psi <br />3,122 K51 <br />4. 2. 2. <br />CONCRETE SHALL 6ON515T OF I" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 1" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4. 2. 3. <br />GROUT SHALL C-ON515T OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX <br />WITH SLUMP BETWEEN ,5" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR <br />ADDITIONAL CRITERIA. <br />4. 2. 4. <br />CONSTRUCTION JOINTS WILL BE PERMITTED <br />4. 2. 5. <br />METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />4. 2. 6. <br />EARTH SUPPORTED 5LAB5 (EXCLUDING EXTERIOR WALKWAYS d DRIVEWAYS) <br />3 1 2" MIN. THICKNESS MIN. REINFORCEMENT OF 6.0 x 6.0 1 4 x l 4 F <br />/ W/ W/ WW <br />IN TOP I-1/2" OF SLAB. FIBER MESH PER DESIGN MIX MAY BE USED I.L.O. HHF <br />CONTRACTORS DISCRETION. <br />4. 2. 1. <br />CONCRETE PLACEMENT PRA TI HA E IN ACCORDANCE <br />G GES S LLB H/ ALL <br />AGI- MCP 2004 STANDARDS. <br />4.3. CONCRETE MASONRY : <br />4. 3. I. <br />FILLED CELLS H/ (1) #5 BAR SHALL BE LOCATED PER PLAN. <br />4. 3. 2. <br />LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE A5TM Gq0-01, TYPE II <br />NON-MO15TURE CONTROLLED. <br />4. 3. 3. <br />ALL CELLS d CAVITIES BELOW GRADE HILL BE FILLED W/ CONCRETE IN ALL <br />STEM WALLS. <br />4.3.4. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI <br />MINIMUM. <br />4. 3. 5. <br />METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE <br />CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />4. 3. 6. <br />MORTAR SHALL BE TYPE "5" FOR ALL MASONRY GON5TRUGTION. <br />4. 3. 1. <br />MASONRY ROUGH OPENING MAY VARY IN THE GROSS SECTION DIMENSION OR ELEVATION <br />DIMENSION 5PEGIFIED ON THE APPROVED PLANS FROM -1/4" TO +1/2" PER SECTION R606.13 <br />4.4. STRUCTURAL LUMBER <br />4. 4. I.I. <br />INTERIOR LOAD BEARING HALLS 5PF, fb = 615 PSI, E = 1200 Ksi <br />ALL EXTERIOR FRAMING 5PF, fb = 615 PSI, E = 1200 Ksi <br />4. 4. 1.2. <br />ALL FRAME WALLS TO BE CONSTRUCTED USING SPF , <br />STUD QUALITY OR BETTER <br />4.4.2. <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS <br />SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4.4.3. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS 5UGH A5 SUB FLOORING AND <br />SHEAR HALLS SHALL BE APA RATED 5HEATHIN6 EXP I U.N.O. <br />4.4.4. <br />IF 05D BOARD 15 TO BE USED IN PLACE OF PLYWOOD 15 TO HAVE SIMILAR OR <br />GREATER SECTION PROPERTIES. <br />4. 4. 5. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN <br />CONTACT WITH CONCRETE 15 TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4. 4. 6. <br />WHEN PRE ENGINEERED TRU55E5 ARE GALLED FOR ON THE PLANS THE <br />MANUFACTURER 15 TO SUBMIT 5HOP DRAWIN65 TO THE ENGINEER OF RECORD. <br />4. 4. 1. <br />DESIGN, FABRICATE AND ERECT WOOD TRU55E5 IN ACCORDANCE WITH THE "DESIGN <br />SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />AN51/TPI 1-02, 5651 1 - 03 <br />4.4.5. <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />4. 4. q. <br />ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 1/b" STUCCO FINISH PER <br />A5TM G. q26, APPLY 3 LAYERS H/ TOTAL THICKNESS 1/5" OVER METAL LATH. FIRST <br />2 LAYERS 3/8" THICK EACH. 31RD LAYER 1/9," THICK <br />4. 4. 10. <br />INSTALLATION OF EXTERIOR LATHING 4 FRAMING SHALL COMPLY TO A5TM G 1063 <br />PER FLORIDA RESIDENTIAL CODE R103.6.2 <br />4. 4. II. <br />FIELD GUT ENDS, NOTCHES AND DRILLED HOLES OF PRE5ERVATIVELY TREATED <br />WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M 4 <br />4.5. FASTENERS AND TIE DOWNS : <br />4. 5. I. <br />FASTENERS AND TIE DOWN5 SHALL GON515T OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS : ASTM A36/361-1 04 Fy = 36 K51 <br />ROUND METAL PIPE : A5TM A53-02, GRADE B Fy = 35 Ksi <br />5QUARE METAL TUBING : A5TM A500-03a, GRADE B Fy = 46K51 <br />HIGH STRENGTH BOLTS : A5TM A325-q4 <br />MACHINE BOLTS : GALVANIZED A5TM A301-03 <br />4. 5. 2. <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fy = 331<51HITH G40 <br />GALVANIZED COATING IN ACCORDANCE WITH A5TM A525-21. <br />4. 5. 3. <br />NAILS SHALL CON515T OF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOWS : Sd = 0.151", IOd = 0.14b", 12d = 0.145", 16d = 0.162". <br />4. 5. 4. <br />ALL FASTENERS AND TIE DOHN5 EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4. 5. 6. <br />ALL FASTENER TIE DOHN5, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRU55 <br />STRAPPING ARE TO BE INSTALLED IN AGGORDANGE WITH THE PLANS AND <br />SPECIFICATIONS. <br />4. 5. 1. <br />CONCRETE EMBEDDED 'J' BOLT5 USED FOR UPLIFT ARE TO BE HET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, 5PAGIN6 AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J" BOLTS ARE NOTED ON PLANS. <br />4. 5. 5. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRU55 AND WALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. <br />4.6. MIGRO-LAM LUMBER: <br />4. 6. I. <br />MICRO -LAM STRESS 6RADE5 SHALL PROVIDE THE FOLLOWING MINIMUM PROPERTIES: <br />E = 2,000,000 P51 <br />Fb = 2,150 PSI <br />Ft = 1850 P51 <br />Fc = 500 PSI (PERPENDICULAR) <br />Fc = 2,100 (PARALLEL) <br />4.1. STEEL: <br />Fv = 255 PSI <br />4. 1. I. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4.1 2. FABRICATE AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH A.I.S.G. <br />"5PEGIFIGATION FOR THE DESIGN, FABRICATION, AND ERECTION OF 5TRUGTURAL <br />STEEL FOR BUILDINGS". <br />4.13. STRUCTURAL STEEL: A5TM A36/36M 04. <br />4. 1. 4. STEEL TUBING: A5TM A500-03a, &RAPE B. <br />4. 1. 5. WELDED CONNECTIONS: EIOXX ELECTRODES, MINIMUM 51ZE FILLET HELDS 3/16", AW5 <br />CERTIFIED HELPERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4,1.6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE HEB STIFFENER <br />PLATES ON EACH 51DE OF THE WEB, OF A THICKNESS EQUAL TO BEAM FLANGE <br />THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. <br />4. 1. 1. THE STEEL FRAME 15 "NON-5ELF 5UPPORTIN6". ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR <br />ELEMENTS ARE IN PLACE. <br />WOR5T CASE DESIGN PRESSURE TABLE <br />BUILDING DATA <br />WIND SPEED 120 MPH <br />WIND IMPORTANCE FACTOR -- (6) = 1.0 <br />WIND EXPOSURE -- 'C' (FRO R301) <br />INTERNAL PRESSURE COEFFICIENT= +/- 0.16 ENCLOSED BLDG) <br />DESIGN IUIND PRE55URE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br />0 END ZONE IS ONLY WITHIN 5'-0' <br />OF ALL EXTERIOR BUILDING CORNERS <br />WINDOWS AND DOORS <br />120 MPH + 363 P5F / - 48.6 PSF (END) <br />+ 363 PSF/ -393 PSF (INTERIOR) U.N.O. <br />GARAGE DOORS (V = 120 MPH) <br />SINGLE 9xl +21.6 PSF / -312 PSF <br />DOUBLE 16x1 +26.4 PSF / -29A PSF <br />NOTE: <br />THESE PRESSURES SUPERSEDE ANY AND ALL PRESSURES <br />LISTED WITHIN THIS CONSTRUCTION DOCUMENT. <br />4. 8. SOIL: <br />4. 8. I. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 P5F. <br />4. 8. 2. ALL SOIL 15 TO BE GLEAN d POISONED FOR TERMITES PER FBG 2001, RESIDENTIAL SECTIONS <br />R320.1, R320.2, R320.3, d R104. <br />TERMITE PROTECTION - <br />PLANS MUST SPECIFY TYPE OF TERMITE TREATMENT <br />• Soil Chemical Barrier Method <br />• Other treatment - Must specify proposed method and submit documentation, which <br />substantiates the proposed method, 15 an approved termite protection system or method. <br />IF CHEMICAL SOIL TERMITE TREATMENT 15 USED <br />I. FBG 105.11- "A permanent sign which Identlfie5 the termite treatment provider and need for <br />re -Inspection and treatment contract renewal shall be provided. The sign shall be posted near the <br />water heater or electric panel" <br />2. Condensate and roof downspouts shall r - <br />a discharge east I' O" away from the building side walls. <br />P g y 9 <br />3. Irrigation/Sprinkler 5g5tem5 Including all r15er5 and spray heads shall not be installed within I'-0" of <br />the -building side wall-. <br />4. FBG R104- To provide for Inspection for termite infestation, between wall covering and final earth <br />gqrade shall not be less than 6 inches. Exception: Paint or decorative cementit)ov5 finish less than <br />5/&" thick adhered directly to the foundation wall. <br />5. R320.1.1 If soil treatment is used for subterranean termite prevention, the Initial chemical loll <br />treatment Inside the foundation perimeter shall be done after all excavation, backfllling and <br />compaction Is complete. <br />6. R320.1.2 If soil treatment is used for subterranean termite prevention, soil area disturbed after <br />Initial chemical soil treatment shall be retreated with a chemical soll treatment, including spaces <br />boxed or formed. <br />1. R320.1.3 If soil treatment 15 used for subterranean termite revention, Space in concrete floors <br />boxed out or formed for the subs n Installation f I mbpl r 'n r n other <br />ectve to p u b n taps, dral s o any of e purpose <br />shall be created by using plastic or metal permanent)yy placed orms of sufficient depth to eliminate <br />any planned 5011 disturbance after initial chemical Soil -treatment. <br />8. R320.1.4 If soil treatment is used for subterranean termite prevention, chemically treated soli shall <br />be protected with a minimum 6 mil vapor retarder to protect against rainfall dilution. If rainfall <br />occurs before vapor retarder placement, retreotment 15 required. Any work, includingq placement of <br />reinforcing steel, done after chemical treatment until the concrete floor is poured, shall be done in <br />such manner as to avoid penetrating or disturbing treated soil. <br />1. R320.1.5 If soil treatment is used for subterranean termite prevention, concrete overpour or mortar <br />accumulated along the exterior foundation perimeter shall be removed prior to exterior chemical soil <br />treatment, to enhance vertical penetration of the chemicals. <br />10. R320.1.6 If soil treatment is used for subterranean termite prevention, chemical soil treatments shall <br />also be applied under all exterior concrete or grade within I foot (305 mm) of the primary structure <br />51dewolls. Also, a vertical chemical barrier Shall be applied promptly after construction Is completed, <br />including initial landscaping and irrigation/sprinkler insicollation. Any soil disturbed after the chemical <br />vertical barrier is applied shall be promptly retreated. <br />II. R320.1.1 If a registered termiticide Formulated and registered as a bait system 15 used for <br />subterranean termite prevention, Sections R320.I.Ithrovgh R310.1.6 do not applyy; however, a signed <br />contract assuring the Installation, maintenance and monitoring of the baiting 5y5 em for a minlmvm of 5 <br />years from the Issue of the Certificate of Occupancy shall be provided to the building official prior <br />io the pouring of the 51ob, and the system must be installed prior to final building approval. <br />12. FBG R320.1 - All buildings are required to have pre -construction treatment. <br />13. R320.1 Termite Protection. Termite protection shall be provided by registered termiticides, includingq <br />soil applied pesticides, baitingq systems and pesticides app Ifed to wood, or other approved methoY <br />of termite protection labeled use as a preventative -treatment to new construction. See Section <br />202, Registered termiticide. Upon completion of the application of the termite protective treatment, <br />p <br />a Certificatef m lian shall 1 o the bull in deportment <br />o Compliance ce s a be s sued t cp g depa tme t N the licensed pest control <br />company that contains the following statement: "The building has received a complete treatment For <br />the prevention of subterranean termites. Treatment is In accordance with rules and laws established <br />by the Florida Department of Agriculture and Consumer Services." <br />14. R320.2 Penetration. Protective sleeves around piping penetrating concrete slab -on- rade floors <br />shall not be of cellulose -containing materials. If 5011 'treatment 5 used for 5ubterran6an termite <br />protection, the sleeve shall have a maximum wall thickness of 0.010 Inch. and be sealed within the <br />slab V51nq a non -corrosive clamping device to ellminotethe annular space between the pipe and the <br />sleeve. go termicides shall be appTled inside the sleeve. <br />15. R320.3 Gleaning. Cells and cavities In ma5onru units and air gaps between brick, stone or masonry <br />veneers and the structure shall be cleaned of all nonpre5ervotive treated or nonnotvrolly durable <br />wood, or other cellulose -containing material prior to concrete placement. <br />4. 0 .3. SOIL 15 TO BE COMPACTED TO 615% MODIFIED PROCTOR AS DEFINED BY <br />A5TM D 1551-00 <br />NOTE: <br />IT 15 THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS <br />BEFORE GONSTRUGTI ON BEG 1 NS. DANSGO ENG1 NEER I NC LLG 15 <br />RESPONSIBLE FOR THE STRUGTURAL INTEGRITY OF THIS PROJEGT <br />ONLY. ANY D I SGREPANGY BETWEEN FIELD CONDITIONS, OTHER <br />DES I ON PROFESS I ONALS' SHOP DRAW I NOS, CONTRACTORS' BU I LD I NO <br />METHODS, AND THESE SIGNED AND SEALED DRAW I NC S MUST BE <br />BROUGHT TO THE ATTENTION OF DANSGO ENGINEERING LLG PRIOR <br />TO THE COMMENGEMENT OF CONSTRUCTION. <br />ATTENTION: GHEMIGAL GHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31 ST, 2003, GHROMATED COPPER ARSENATE (GGA-C) <br />HILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR GENERAL CONSUMER <br />USE. 5EVERAL NEW PRESSURE TREATED HOOD ALTERNATIVES HAVE BEEN <br />GREATED TO REPLACE GGA-C. MANY OF THE NEH PRESSURE TREATED <br />HOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT 15 THE <br />CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF HOOD TREATMENT <br />AND TO SELECT APPROPRIATE GONNEGTORS THAT RESIST GORR0510N. <br />FOR EXAMPLE, AGG2-C, AGO-D, GBA-A, OR GA-B REQUIRE HOT -DIPPED <br />GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (5BX) <br />DOES NOT. <br />REOU I RED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FRG R308.4) <br />R30b.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INGLUDING GLA55 MIRRORS IN HAZARDOUS <br />LOGATION5 SUCH A5 THOSE INDICATED A5 DEFINED IN SECTION R30B.4 SHALL PA55 THE TEST REQUIREMENTS <br />OF GPSG 16 GFR, PART 1201 CRITERIA FOR CATEGORY I OR CATEGORY II A5 INDICATED IN TABLE R308.3 <br />EXCEPTIONS: <br />I. POLISHED WIRED 6LA55 FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL <br />COMPANY WITH AN51 ZcM.l <br />2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R308.2 <br />R3O8.4 HAZARDOUS LOCATIONS. <br />THE FOLLOWING SHALL BE CONSIDERED 5PEGIFIG HAZARDOUS LOCATIONS FOR THE PURPOSE OF <br />GLAZING: <br />I. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. <br />2. &LAZIN& IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN 5LIDIN& <br />AND BIFOLD CLOSET DOOR ASSEMBLIES. <br />3. GLAZING IN STORM DOORS. <br />4. GLAZING IN ALL UNFRAMED SHIN IN R G G DOORS. <br />5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS, AND 5HOWER5. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE <br />COMPARTMENTS WHERE THE BOTTOM EXP05ED EDGE OF THE GLAZING 15 LESS THAN 60 INCHES <br />(1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE <br />NEAREST VERTICAL EDGE 15 WITHIN A 24-INGH(610MM) ARC, OF THE DOOR IN A GLOSED P051TION <br />AND WHOSE BOTTOM EDGE 15 LE55 THAN 60 INCHES (1524MM) ABOVE THE FLOOR OR WALKING <br />SURFACE. <br />1. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br />1.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN q 5QUARE FEET (02336 1`12). <br />1.2 BOTTOM EDGE LE55 THAN Ib INCHES (451 MM) ABOVE THE FLOOR. <br />1.3 TOP EDGE GREATER THAN 36 INCHES (ql4 MM) ABOVE THE FLOOR. <br />1.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES (q14 MM) HORIZONTALLY OF THE <br />GLAZING. <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE. <br />INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. <br />q. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR 5WIMMIN6 POOLS, HOT TUB5 <br />AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LE55 THAN 60 INCHES (1524 MM) ABOVE A <br />HALKIN6 SURFACE AND WITHIN 60 INCHES (1524 MM ) HORIZONTALLY OF THE HATER'S EDGE. THIS <br />SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. <br />10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES (1114 MM) <br />HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS 15 LE55 THAN <br />60 INCHES (1524 MM) ABOVE THE PLANE OF THE ADJACENT HALKIN6 SURFACE. <br />11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM <br />TREAD OF A 5TAIRHAY IN ANY DIRECTION WHEN THE EXP05ED SURFACE OF THE GLASS 15 LE55 <br />THAN 60 INCHES (1524 MM) ABOVE THE N05E OF THE TREAD. <br />EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS <br />LOCATIONS: <br />I. OPENINGS IN DOORS THROUGH WHICH A 3-IN(;H(16 MM) SPHERE 15 UNABLE TO PASS. <br />2. DECORATIVE GLASS IN ITEMS 1, 6 OR 1, <br />3. GLAZING IN SECTION R3045.4, ITEM 6, HHEN THERE 15 AN INTERVENING WALL OR OTHER PERMANENT <br />BARRIER BETWEEN THE DOOR AND THE GLAZING. <br />4. &LAZING IN SECTION R 308.4, ITEM 6, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A <br />GLO5ED P051TION OR WHERE ACCESS THROUGH THE DOOR 15 TO A GL05ET OR STORAGE AREA 3 <br />FEET 014 MM) OR LE55 IN DEPTH. &LAZING IN THESE APPLICATIONS SHALL COMPANY WITH <br />SECTION R308.4, ITEM 1. <br />5. GLAZING IN SECTION R308.4, ITEMS 1 AND 10, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE <br />ACCESSIBLE 51DE(5) OF THE GLAZING 3(o INCHES ± 2 INCHES (6114 ± MM 51 MM) ABOVE THE FLOOR. <br />THE BAR SHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS PER LINEAR <br />FOOT KG/M) WITHOUT CONTACTING THE 6LA55 AND BE A MINIMUM OF I Y INCHES (39, MM) IN <br />HEIGHT. <br />6. OUTBOARD PANES IN INSULATING GLA55 UNITS AND OTHER MULTIPLE GLAZED PANELS IN SECTION <br />R30B.4, ITEM 1, WHEN THE BOTTOM EDGE OF THE GLASS 15 25 FEET (7620 MM) OR MORE ABOVE <br />GRADE, A ROOF, WALKING SURFAGE5, OR OTHER HORIZONTAL [WITHIN 45 DE6REE5 (01cf RAP) OF <br />HORIZONTAL] SURFACE ADJACENT TO THE 6LA55 EXTERIOR. <br />1. LOUVERED HIND0H5 ANP _I,ALOU51E5 COMPLYING WITH THE REQUIREMENTS OF SECTION <br />R308.2. <br />8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A <br />CONTINUOUS BACKING SUPPORT. <br />q. SAFETY GLAZING IN SECTION R30&.4, ITEMS 10 AND II 15 NOT REQUIRED HHERE: <br />q.1 THE SIDE OF 5TAIRHAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING <br />BALUSTERS OR IN -FILL PANELS, COMPLYING HITH THE PREVISIONS OF SECTION 1012 AND <br />1601.7 OF THE FLORIDA BUILDING CODE, BUILDING; AND <br />q.2 THE PLANE OF THE 6LA55 15 GREATER THEN 18 INCHES (451 MM) FROM THE RAILING. <br />GLA55 BLOCK INSTALLATION PERFORMED IN ACCORDANCE WITH FRO / FBG <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR <br />B) ADHERE EXPANSION STRIPS TO JAM55 AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL, <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK MAINTAIN A UNIFORM JOINT WIDTH OF 3/8' PLUS OR MINUS <br />1/8'. ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE 'S' OR 'N'. STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING 'SQUEEZED' OUT. <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN (o INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING_ INSTALL <br />REINFORCING AS FOLLOWS: <br />PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />PRESS PANEL REINFORCING INTO PLACE. <br />COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR <br />N) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY, <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL 5ET (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLA55 BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR 5EALIN( <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH,, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK <br />20 ga. PANEL <br />ANCHOR -\ <br />9 ga. PANEL <br />REINFORCING <br />(EVERY <br />OTHER <br />.COURSE)-\ <br />� \- SEALANT <br />GLA55 BLOCK DETAIL <br />EXPANSION STRIP <br />1/4" EXPANSION <br />BOLT (2 PER <br />ANCHOR) <br />EXPANSION STRIP <br />ro" MIN. LAP SPLICE <br />W/ REINFORCING <br />PANEL <br />NOTE: <br />SEE GLA55 BLOCK <br />INSTALLATION NOTES. <br />:(110 mph FASTEST WIND = 130 mph, 3 SEC. GUST. FRO TABLE R3012.13) <br />�(110 mph FASTEST WIND = 130 mph, 3 SEC. GUST. FBG TABLE 1606.1.6.1) <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineefng.com <br />Ln <br />Z pp <br />C <br />0rn <br />.�I <br />z <br />t1mIn <br />M N <br />z <br />Q C 0�0 <br />Z <br />3� <br />WJ <br />z <br />J <br />� <br />F- <br />LLJ <br />2 <br />Q <br />Z <br />TO THE BEST OF THE ENGINCDT'S KNOWLEDGE AND <br />BELIEF. THE STRUCTURAL PLANS AND SPECIFICATIONS <br />COMPLY WITH 2O07 FLORIDA RESIDENTIAL BUILDING <br />CODE INCLUDING 2009 SUPPLEMENT), SECTION <br />R301 FOR 120 ANTI, 3 SEC. GUST. EXPOSURE 'C <br />ENCLOS® INTERNAL PRESSURE COEFHCIENT=3D.iBI <br />WIND ZONE. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />ED2010 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />020104THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING. LLC AND THE <br />CLIENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />02.02.09 <br />1.0 2007 FBC UPDATES <br />10,29.09 <br />1.01 FFPC 2007 UPDATE <br />05,07.10 <br />2.00 GP FIREWALLS <br />07 28.10 <br />3.00 ADD ALT. F <br />SHEATHING <br />VERSION NO.3.00 / 07.28.10 <br />CA 25948 <br />SAMUEL A. GREENBERG, <br />P.E. #34245 <br />THUY H. HUYNH, <br />7' P.E. #60122 <br />El IRWIN J. BENSON, <br />P.E. #49758 <br />El ANDREW D. HAROLD, <br />P.E. # itWA •1••_ <br />Nth <br />.•`'���1�bl�/L: <br />TR wa <br />:O•• TATEOF ••�¢ <br />••,••••►� Nt,TITLE: <br />STRUCTURAL NOTES <br />SHEET INFORMATION: <br />JOB NO.: 290127 <br />DATE ISSUED: 02.02.09 <br />DRAWN BY: DZ <br />REVIEWED BY: WAS <br />SIN <br />IT- <br />O <br />iV <br />1 <br />C' ) <br />LO <br />M <br />a- <br />LO <br />11­ <br />I11L_110 <br />