FLASHING REQUIREMENTS <br />WEATHER RESISTIVE <br />FLASHING AND SEALANTS FOR EXTERIOR WINDOW AND DOOR OPENINGS SHALL COMPLY WITH <br />BARRIER <br />WINDOW UNIT <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />SECTION R703.4. <br />_ <br />DOOR ROUGH OPENING <br />-= <br />SLOPE <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />R703.2 WATER -RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM HOLES AND <br />- <br />WOOD FRAME " a ;` <br />0.3 in: 12.0 in <br />BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED WATER -RESISTIVE <br />SELF -ADHERED FLASHING ;;;. <Illl"' <br />FLASHING <br />3DHE BEAD OF <br />( O.6 Cm : 30.5 Cm <br />BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELT OR <br />BY LAPPING DOWN = <br />OVER RIM JOIST AND UP <br />ADHESIVE TO BE APPLIED UNDER <br />APPLIED <br />THRESHOLD OF DOOR AND RETURN <br />SELF -ADHERED FLASHING <br />SELF -ADHERED F LAS H I N G <br />MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER <br />LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT <br />WALL BY 6 IN. _ <br />_: <br />UP JAMB 6'. USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />EXTERIOR <br />PRODUCTS DETAILS <br />LESS THAN 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A <br />_ <br />CEMT.FIN. <br />MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN <br />- - <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />SECTION R703.1. THE WATER -RESISTIVE BARRIER IS NOT REQUIRED FOR DETACHED ACCESSORY <br />- <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />BUILDINGS. <br />SEAL TOPS OF JOISTS :.. _ :.. <br />WIRE LATH <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />UNDER DECKING <br />"lrq - <br />SUBFLOOR <br />(SEE DETAIL WP07) "' <br />.; <br />R703.4 FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED <br />RIM JOIST <br />Detail Instructions <br />MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />7Refer <br />VAPPROPRIATE <br />to the number marked as in each detail that corresponds to <br />PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT <br />COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT <br />the numbered items in the lis of instructions below: <br />EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS <br />FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN <br />2 <br />O <br />1. Install self -adhered flashing in order as shown by numbers <br />EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />INSTALLED AT THE FOLLOWING LOCATIONS: <br />SELF -ADHERED FLASHING <br />P02 <br />FW <br />SELF -ADHERED FLASHING <br />W P03 <br />3. Self -adhered flashing can be substituted for building paper <br />1• EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL EXTEND TO THE SURFACE THE EXTERIOR WALL FINISH OR THE <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />4. Split the release paper using the ripcord (Split release on <br />P P P 9 P ( P <br />SE <br />WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. <br />AI <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT <br />EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />FOLD UP WEATHER <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />EXTERIOR SHEATHING <br />3/4"-t" BEAD OF CONSTR.ERED <br />ADHESIVE TO BE APPLIED UNDER <br />FLASHING JAMB 6INSTALL SELF-ADHHEAD <br />RUBBERIZED <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />5- Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing material <br />MORE OF THE FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR <br />WEATHER <br />THRESHOLD OF DOOR AND RETURN <br />FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING s`7":`.`.' <br />(6" X 6" Minimum) <br />FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S <br />RESISITIVE <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />FLANGED WINDOW <br />":%" t:;' <br />:.,;.;;;. <br />INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. <br />BARRIER <br />OR EQUAL WEATHER PROOF CAULKING <br />(SEE DETAIL WP01) <br />6. Fold as shown by arrows <br />WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE <br />TAPE <br />EXTERIOR <br />(„gym` ^`''"A SCORED <br />7. Angle of comer may vary, adjust folding of the flashing <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL <br />SHEATHING <br />RELEASE PAPER <br />accordingly to fit tight to comer <br />BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE <br />-(BEFORE <br />SELF -A"•';•`' <br />EXTENDAMINIMHERED LASHING, <br />EXTEND A MINIMUM 6" <br />FOLDING, SCORE <br />_� RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />8. Mechanical) fasten as necessary <br />y ry <br />EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER FOR SUBSEQUENT <br />DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR <br />?',2. <br />VERTICALLY FROM <br />PROTECTION AT THE HEAD AND SIDES. <br />:.:. :::, •,. :n <br />••:•-:•- ""�:: •%>:_• "`''? <br />2 <br />WEATHER <br />'`' ''_ - RESISITIVE <br />BARRIER <br />' <br />BOTTOM OF <br />THRESHOLD <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN <br />PROFESSIONAL. <br />:"•: fc� <br />-_= <br />SECTION -A (SEE DETAIL WP02) <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. <br />1.41N ACCORDANCE WITH FMA/AAMA 100, FMA/ AAMA 200, FMANVDMA 250, FMA/AAMA/ WDMA 300 <br />;- <br />SELF -ADHERED FLASHING <br />'O <br />OR FMA/AAMANVDMA 400- <br />2. AT THE INTERSECTION <br />`:;'. <br />2 <br />OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />1. Cut, fold up 8 temporarily secure weather resistive <br />SELF -ADHERED FLASHING:• ` <br />5 <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. <br />barrier above header to allow for flashing <br />installation <br />' <br />O <br />4 <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />1 <br />SEAL TOPS OF JOISTS <br />1 <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />3. Fold weather resistive barrier back over head <br />2 <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />2 <br />7 <br />6. AT WALL AND ROOF INTERSECTIONS. <br />flashing and seal with tape <br />7. AT BUILT-IN GUTTERS. <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />Scale: NTS <br />WPM <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />EWP05 <br />SELF -ADHERED FLASHING <br />INSIDE <br />WP06 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />CORNER <br />EXTERIOR SHEATHING � <br />�Ground� <br />SHEATHING <br />- <br />t <br />7/8" Cement Plaster <br />" <br />7/8 Cement Plaster <br />REFER TO TECHNICAL <br />_ _ <br />�'<¢„<Y;,•-•_ <br />in accordance With <br />in accordance with <br />LETTER ON CHEMICAL <br />::;,•.; , ..,;;.-:` <br />Water Resistant Barrier <br />ASTMC926 <br />ASTMC926 <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />_ _ <br />Lath <br />Felt backed metal <br />Felt backed metal <br />= <br />SELF -ADHERED FLASHING <br />- g <br />Iat <br />lathe e n accordance <br />lathe in accordance <br />PATCH <br />With ASTMC1063 <br />with ASTMC1063 <br />Stucoo <br />• .. <br />............. <br />Building Paper <br />Buildingr <br />Paper <br />Pe <br />- <br />- _ _ _ _ _ <br />..:.... ...._.. .:.::R-:::.,::.:...._._.. �;..saa::�::.. <br />A • <br />• : <br />i " <br />i 7/16 O.S.B. <br />" <br />, 7/16 O.S.B. <br />ten... • <br />^ :;. <br />:: <br />SELF FLASHING <br />::;;;;;;r.::::..::::...::....::.. ............... ......:..:....::u:.. ,...::::.:.-:,::n•:.�:s::::.. <br />..:;::::::::=:::..;;;::,::;.;:;�::...::::.::... :....::'�:,::-;.��-;> _::_;_ � .. ::r:::;•::_.:...:..n , , <br />:";`"'" :R.za :::a:::c:;a::=;r,;s•;_.: <br />. a• <br />:......::::. , , � . sheathin <br />sheathin 9 <br />• <br />-ADHERED <br />.:_• <br />................ <br />i <br />SELF -ADHERED FLASHING <br />Foundation Wall'• •'. ' <br />' <br />Metal <br />• <br />SELF -ADHERED FLASHING "" > `<•': :' •':%£ 1 >t: <br />%-4-' <br />. �. . <br />Flashing <br />;•:;.. tt:• ..:.. <br />NAILING FLANGE 1 <br />3" MIN <br />2 <br />+ • ; <br />Weep Screed <br />Installed As Per <br />2 <br />4 <br />Manufact. Specs. & <br />Stampede or similar <br />DO NOT FLASH OVER <br />FRC R703.7.2.1 <br />cejoint my <br />BOTTOM NAILING <br />8 <br />5 <br />FLANGE <br />Maintain <br />Bottom of <br />Weep Screed <br />SELF -ADHERED FLASHING <br />WP04 <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />KP08 <br />FOUNDATION WEEP SCREED <br />WP09 <br />Weep Screed <br />2" Above Roof <br />Installed As Per <br />& <br />FRCR <br />HALF ROUND WINDOW <br />0.Spe1 <br />Sheathing <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer Will <br />need to be miter <br />Cement Plaster <br />cut and caulked all <br />in accordance <br />butt joints need to <br />with ASTMC926 <br />becaulked using <br />over wood 2nd <br />Stampede or sim. <br />floor <br />caulk for all <br />DOUBLE <br />JOIST <br />SINGLE <br />WOOD BEAM <br />JOIST <br />BELOW <br />SELF -ADHERED <br />SELF -ADHERED <br />FLASHING <br />FLASHING O <br />2 <br />Cement <br />SELF -ADHERED FLASHING <br />�/rr/P07 <br />DECK JOIST <br />V V <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. WEEP <br />SCREED DETAIL <br />NOT USED <br />NOT USED <br />NOT USED <br />SCALE: NOT TO SCALE <br />1111 <br />Im <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />1. 813.645.9698 <br />www.danscoengineedng.com <br />CA 25948 <br />� <br />p <br />o <br />acCRCn�� <br />z <br />Q�CV)en <br />Z <br />Ln <br />¢aN_J <br />ZaF-CaaM <br />�Q o <br />Wz3 <br />o <br />U <br />i2 <br />LU <br />W <br />LU = <br />CL <br />LU to <br />= O � <br />� � <br />J <br />Q I m <br />LU <br />Q O 130 <br />Q I-_ m <br />O <br />Z LU <br />Z <br />Z 00 <br />(N <br />C/)O � <br />11 <br />V) <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd = I OBMPH), 3 SEC. GUST, <br />EX OSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = 30.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SKoNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHS DRAWINGONLY. <br />02019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019 - THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUTHORIZED USE IS PROHIMED. <br />REVISION: <br />DATE <br />DESCRIPTION <br />UPDATED CONNECTION <br />06.08.18 <br />1.01 CROSS-REFERENCE TABLE <br />AND STAIR STRAP <br />01.09.19 <br />1.02 ROOF UNDERLAYMENT REV. <br />02.11.19 <br />1.03 UPDATED CONNECTION <br />CROSS-REFERENCE TABLE <br />VERSK)N <br />NO. 1.03 / 02.11.19 <br />o "�nanr,as>faaa <br />N <br />IIJn <br />o c\� <br />Q <br />LU O <br />Co J <br />w 0 <br />-� LLI = U <br />W C� Z <br />W wM ='O Do <br />UJ =* }* Lu* <br />Z Q <br />LLi = ui oe LLi <br />V) �� 0-0- <br />W ❑ ❑ <br />SHEET TITLE: <br />WATERPROOFING DETAILS <br />SHEET INFORMATION: <br />JOB NO.: 390440 <br />DATE ISSUED: 04.04.19 <br />DRAWN BY: LF <br />REVIEWED BY: TH <br />W P <br />O <br />00 <br />O <br />I <br />CAI <br />r_1 <br />I <br />Ob <br />LO <br />9- <br />