My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6328 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6328 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:07:49 AM
Creation date
2/19/2025 10:57:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6328
Location
Cobble Bliss St
Contractor
Lennar Homes LLC
Building Plans - Permit #
21420
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l TYP.I I ; I (TYR) <br />I I <br />� I <br />4'-01 <br />yrO OFF -RIDGE �e <br />VENT <br />I � <br />�I <br />OFF -RIDGE z OFF -RIDGE <br />VENT '` VENT <br />SLOPE 5:12 SLOPE 5:12 <br />NOTE: <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF <br />INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF <br />SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. <br />y� <br />ISSUANCE OF PLANS FROM THIS DESIGNERS OFFICE SHALT. NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE <br />BUILDING CODES PRIOR TO COMMENCEhENT OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DES&ERS OFFICE FOR CORRECTION BEFORE <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL. PLANS HAVE BEEN COMPLETED SHALT. BE SA39CT TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE <br />DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE <br />RIDGE VENT SEE SHEET b FOR f' MATERIAL INFO <br />I� <br />Ems% NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO <br />ACCESS TO EXTERIOR THROUGH A DOOR THE <br />WINDOW MUST HAVE A MAXIMUM SILL HEIGHT OF <br />44' MEASURED FROM THE FINISHED FLOOR OF <br />THAT PARTICULAR ROOM TO THE BOTTOM OF <br />THE CLEAR OPENING. <br />-23 <br />I 1=RONfi �L�Y�4�'ION II�II <br />SCALE: 1/4'=I'-0' <br />gill <br />� 0 <br />Im IN F ��7 <br />I � <br />I � <br />I O I <br />I I <br />�lFr I <br />I <br />I'-m' <br />(TYP.) 12 12 12 <br />I <br />e <br />SLOPE 5:12 I 5 5 5 t OFF RIDGE VENT <br />TRU55ES PER PLANS <br />I <br />----------------- a ------ SHINGLE ROOF PER SPECS <br />L---------- --- -------------J <br />O ROOF VENT 5CHE:DULE O <br />Verify with C-4awal Contractor all roof vent <br />locations, quantities, and sizes. Roof valts shell <br />be Installed for a minimum of vented area as listed <br />below or equ►valen, system per 6TH ED. (2fd1'1) <br />FRC, R8®bZ <br />Mark <br />Location <br />of vents or <br />equal system (sq. in) <br />fftt vent <br />(sq. in.) <br />RV I <br />Main <br />Roof <br />194 <br />134 <br />2'-2' <br />2 ROOF FLAN <br />SCALE: 1/8'=1'-0' <br />RIDGE VENT <br />o I�5 <br />SHINGLE ROOF PER SPECS. <br />STUCCO FINISH <br />SEE DET. 5/SNI FOR <br />WEEP SCREED INFO — <br />.mll 11ml " I " I [�', <br />RIDGE VENT <br />SCALE% I/8'+1'-0' <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineedng.com <br />CA 25948 <br />0 <br />0 <br />N <br />QZ O = <br />o�MLn <br />zaLn <br />u<7Z <br />la—°'aM <br />1�H00 <br />W zo <br />J � <br />W <br />Q w <br />LLJ Z Lu <br />��o V) <br />Q <br />Q w C/) <br />Lu I <br />p w v m <br />'.qt Lu L L1J <br />U W -' <br />z�<`" m <br />Qo< <br />U '0 U <br />u <br />i u M <br />M 10 <br />Q <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />6TH EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd= I OBMPH), 3 SEC. GUST. <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = 30.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OFTHIS DRAWINGONLY. <br />e 2019 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />02019•THESE DRAWINGS AND DESIGNS ARETHE <br />JOINT PROPERTY OF DANSCO ENGINEERING, LLC AND <br />THE CLIENT ON THIS PROJECT. ANY REPRODUCTION <br />OR UNAUMORLZED USE D PROHIBITED. <br />REVISION: <br />RIDGE PENT DATE DES�CRIIPTION <br />12.12.17 1.00 UPDATES <br />07.31.18 1.01 RLEV. A TRUSS LAYOUT <br />01.25.19 1.02 BEARING WALL NOT <br />o U RIMPATN Hl A ILO <br />RIDGE VENT 5 12 , 02.07.19 1.03 <br />5 <br />SHINGLE ROOF �' <br />PER SPECS. VERSION N/Qy�: I,Q / 02.07.19 <br />Tir4 .0 <br />T. HEEL ELEV. 5-I0' <br />3-0 <br />T. <br />T. BLOCK ELEV. 84' <br />F25 STUCCO FINISH 'F� <br />IF71 <br />SEE DET. 5/5NI FOR i <br />WEEP SCREED INFOOL <br />F. FLOOR ELEV. ml-/J,, <br />5 RICN����4�'ION II�II 0_ <br />CV <br />T. BLOCK ELEV, <br />- STUCCO FINISH <br />- SEE DET. B/SNI FOR <br />WEEP SCREED WO <br />0 <br />c1C <br />w <br />O <br />Z <br />w <br />J <br />O <br />= <br />U <br />W <br />r <br />COS N <br />QN <br />< <br />W <br />=N <br />w� _1 <br />r iIt <br />}00 <br />W <br />z <br />�* }4t; <br />w <br />a <br />Q LLi = . <br />cn Li L— a- <br />W LLI <br />o_ � <br />W <br />❑ <br />❑ <br />SHEET TITLE: <br />ELEVATION "A" EXTERIOR <br />ELEVATIONS <br />8° ROOF PLAN <br />SHEET INFORMATION: <br />JOB NO.: <br />390440 <br />ISSUANCE OF FLANS FROM THIS DES&M OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL. NOTES, OMENSIONS, AND ADHERENCE TO APPLICABLE <br />DATE ISSUED: <br />04.04.19 <br />BUILDING CODES PRIOR TO GOMTNC»Ni OF ANT' CONSTRUCTIN <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING <br />DRAWN BY: <br />JH <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE FOR CORRECTION BEFORE <br />REVIEWED BY: <br />TH <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANT' REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL PLANS WAVE BEEN COMPLETED SHALL BE SU11W To ADDITIONAL. FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE <br />3A <br />DESK> m OFFICE, THE DES&O SHALL NOT BE HELD RESPONSIBLE <br />L-J <br />h <br />00 <br />CV <br />LO <br />1— <br />
The URL can be used to link to this page
Your browser does not support the video tag.