OPTIONAL OVERHEAD SERVICE 5AME A5 <br />150 = ' COPPER OR 2/0 ALUMINUM <br />UNDERGROUND 150 OR 200 AMP 5ERVICE <br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT, <br />METER <br />TYPICAL =====fA/C <br />MAIN D15G. ELECTRICAL DI5CONNECT <br />150 OR PANEL <br />REFER TO FLOOR PLAN FOR <br />200 AMP 12 COPPER TO APPLIANCES AND GFI <br />NOTED AMPS. REQUIRED <br />14 COPPER TO LIGHT5 AND OUTLET5 <br />`10 COPPER TO WATER HEATER <br />UNDERGROUND 5ERVICE <br />18 COPPER TO RANGE <br />BY POWER COMPANY <br />% COPPER TO HVAC <br />04 GROUNDING WIRE WITH CODE <br />APPROVED CLAMP PER 250.50 <br />AND 25052 OF THE 2014 NEC, <br />INTER5Y5TEM BONDING TERMINATION PER NEC 08, 250.94 <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIALS AND IN5TALLATION5 5HALL COMPLY W/ APPLICABLE PROV151ON5 <br />OF THE NFPA 10-06, LOCAL GODE5 AND LOCAL POWER/UTILITY COMPANY <br />5TAIR NOTE5 <br />RAILING <br />BALU5TER5 5HALL BE SPACED 50 THAT A 4" SPHERE CANNOT PA55 THROUGH. <br />HANDRAILS <br />HANDRAIL5 FOR 5TAIRWAY5 5HALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWE5T RISER HANDRAIL END5 5HALL BE RETURNED OR 5HALL TERMINATE IN NEWEL P05T5 OR <br />5AFETY TERMINAL5. HANDRAIL5 ADJACENT TO A WALL SHALL HAVE A 5PACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAIL5. <br />CONTINUOUS GRA5PABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER -STAIR PROTECTION <br />ENCL05ED ACCE551BLE 5PACE UNDER 5TAIR5 5HALL HAVE WALLS, UNDER-5TAIR SURFACE AND ANY SOFFIT PROTECTED ON THE <br />ENCLOSED 51DE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RE51DENTIAL 6th EDITION (2011) - R302.1 AND R302.11 <br />STAIRWALL FRAME NOTE <br />ALL 5TAIRWELL 5URROUNDING WALLS AND KNEE WALL5 ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD <br />OCCUPANCY AND CON5TRUCTION TYPE: <br />TH15 UNIT HA5 AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA551FICATION, <br />CEILING CON5TRUCTION. <br />I. THE GARAGE 5HALL BE 5EPARATED FROM THE RESIDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD APPLIED <br />TO THE GARAGE 51DE, GARAGE5 BENEATH HABITABLE ROOM5 5HALL BE SEPARATED FROM ALL HABITABLE ROOM5 ABOVE BY NOT LE55 THAN <br />5/8 INCH (15.9 mm) TYPE "X" GYP5UM BOARD OR EQUIVALENT. WHERE THE 5EPARATION 15 A FLOOR -CEILING A55EMBLY, THE 5TRUCTURE <br />5UPPORTING THE 5EPARATION 5HALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYP5UM BOARD OR EQUIVALENT. <br />DUELLING / GARAGE OPENING5: <br />I. THE OPENING BETWEEN THE GARAGE AND LIVING AREA 5HALL BE EQUIPPED WITH SOLID WOOD DOOR5 NOT LE55 THAN 13/8" IN THICKNESS, <br />50LID CORE (5.C.) OR HONEYCOMB CORE 5TEEL DOOR5 NOT LE55 THAN 13/8" THICK, OR 20 MINUTE FIRE RATED DOOR5. <br />2. ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PACE MU5T BE EITHER A 50LID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTE5. <br />EGRE55: <br />EACH BEDROOM MU5T HAVE ONE WINDOW THAT COMPLIE5 WITH EGRE55 CODE5, IF THERE 15 NO AGGE55 TO EXTERIOR THROUGH A DOOR, THE <br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. <br />WINDOW IN5TALLATION: <br />WINDOW5 5HALL BE I1\15TALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION IN5TRUCTION5. WRITTEN <br />INSTALLATION IN5TRUCTION5 5HALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW, <br />TERMITE PROTECTION: <br />I. PENETRATION. PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOOR5 5HALL NOT BE OF CELLULOSE <br />CONTAINING MATERIAL5. IF 501L TREATMENT 15 U5ED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE 5HALL HAVE A MAXIMUM WALL <br />THICKNESS OF 0.010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-GORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PACE <br />BETWEEN THE PIPE AND THE 5LEEVE. NO TERMITICIDE5 5HALL BE APPLIED IN51DE THE 5LEEVE. <br />2. PROTECTION AGAINST DECAY AND TERMITES. - CONDENSATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR 5PRAY HEADS, AND ROOF <br />DOWN5POUT5 5HALL D15CPARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTEN51ON5, OR 5PLA5H BLOCK5. GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDING5 WITH EAVE5 OF LE55 THAN 6 INCHE5 (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKE5 OR ON A ROOF ABOVE ANOTHER ROOF. <br />I <br />TOP RAILING <br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION <br />BALU5TER5 TO NAIL5 ON WOOD COMPONENTS, <br />MAX SPACING 4" <br />1 X 8 PAINTED WE). CAP 5TRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO <br />OGEE 5TOP THE 51ZE OF A 2 X 12 5.Y.P. AND 15 NAILED TO EACH <br />TREAD W/ 16d NAILS FROM THIRD LAMINATE TO TREAD— <br />OPT, 2 X 2 BLOCKING NAILED / <br />TO TREAD AND RISER. <br />3-2 X 12 5TRINGER 2 X BLOCKING NAILED TO 5TRINGER, Z + <br />3/4" R15ER5 RISER, AND TREAD. + <br />2 X TREADS± RIP FROM 2x12 I X 5PRUCE 13 OR 3/4" CDX. + <br />TO 51ZE NOTED ON PLAN PLYWD. RISER. <br />2 X 5OUTHERN YELLOW PINE 01 <br />(ACTUAL THICKNESS 15 1 1/2") TREAD, <br />TYP. OPT. RAILING ELEVATION <br />5CALE: 1/2" = 1411 <br />NEWEL P05T <br />TOP RAILING <br />BALU5TER 4" O.C. <br />5HOE RAIL (REMOVE <br />W/ METAL SPINDLES) <br />I X 8 PAINTED WD. CAP <br />OGEE STOP <br />r uuK LINt _ <br />OPTIONAL <br />A RAILING DETAIL <br />CLOSED RISER DETAIL <br />5CALE: 1/2" = 1'-0" <br />CARPf <br />CARPS <br />TREAD <br />R15ER <br />2X4WALL <br />1/2" GYP BD. <br />3/4" SKIRT BD. <br />2 X 4 5PACER <br />2X12 <br />5TRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B 5CALE: 3/4" = I'-0" <br />GENERAL CONSTRUCTION NOTES <br />CHAPTER5 AND 5ECTION5 REFER TO F.B.C. RESIDENTIAL 6th EDITION (2011) <br />MECHANICAL AND HVAC <br />I. ENERGY CALCULATION5 FOR HEATING AND COOLING CAPAGITIE5 5HALL BE FURN15HED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO <br />TH15 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCE5 5HALL BE ACCE551BLE FOR INSPECTION, 5ERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />GON5TRUCTION, OTHER APPLIANCE5, OR ANY OTHER PIPING OR DUCT5 NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, <br />REPAIRED, OR REPLACED. A LEVEL WORKING 5PACE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE 5HALL BE PROVIDED IN <br />FRONT OF THE CONTROL 51DE TO 5ERVICE AN APPLIANCE. <br />3. DUCT5 IN THE GARAGE AND DUCT5 PENETRATING THE WALL5 OR CEILING5 5EPARATING THE DWELLING FROM THE GARAGE 5HALL BE <br />CONSTRUCTED OF A MIN. 126 GAUGE (0.48 mm) 5HEET 5TEEL OR OTHER APPROVED MATERIAL AND 5HALL HAVE NO OPENING5 INTO THE GARAGE. <br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 5HALL BE RAISED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FIN15HED <br />GRADE AND 5HALL AL50 CONFORM TO THE MANUFACTURER'5 INSTALLATION IN5TRUCTION5. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCE5 5HALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR A5 A RE5ULT OF 5TOPPAGE IN THE CONDENSATE DRAIN PIPING 5Y5TEM. THESE PANS 5HALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV1510N5 OF 5ECTION5 MI411.3. <br />EXHAU5T FANS AND VENTING: <br />(.OUTDOOR D15CHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAU5T 5Y5TEM 5HALL BE D15CHARGED TO THE OUTDOOR5. AIR 5HALL <br />NOT BE EXHAU5TED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL 5PACE. <br />2, EXHAU5T AIR FROM BATH ROOM5 AND TOILET ROOM5 5HALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND <br />5HALL BE EXHAU5TED DIRECTLY TO THE OUTDOOR5. EXHAU5T AIR FROM BATHROOMS AND TOILET ROOM5 5HALL NOT D15CHARGE INTO AN ATTIC, <br />CRAWL 5PACE, OR OTHER AREA5 IN51DE THE BUILDING. <br />3. DUCT LENGTH. THE MAXIMUM LENGTH OF A CLOTHE5 DRYER EXHAU5T DUCT 5HALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT 5HALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND <br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOES NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 IN5TALLED AND 1­15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAU5T DUCT, INCLUDING ANY TRAN51TION DUCT, 5HALL BE PERMITTED TO BE IN ACCORDANCE WITH THE 5005TER FAN MANUFACTURER'S <br />IN5TALLATION IN5TRUCTION5. WHERE A CLOTHES DRYER 8005TER FAN 15 INSTALLED AND NOT READILY ACCE551BLE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL 5HALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTER5 THE WALL. THE <br />LABEL 51-1ALL BEAR THE WORD5 "TH15 DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN." <br />4. PROVIDE LOUVER DEVICE5 AT INTAKE AND EXHAU5T LOCATION5 IN ACCORDANCE WITH <br />AMCA 5TANDARD 550 IN FBC, <br />ROUGH -IN IN5PECTION REQUE5T NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MU5T BE <br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUE5TING THE <br />FRAMING INSPECTION. <br />WINDOW FALL PROTECTION <br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 <br />LOCATED MORE THAN 12 INCHE5 ABOVE THE FINI5HED GRADE OR <br />5URFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE <br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINI5HED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE <br />5ECTION5 OF WINDOW5 SHALL NOT PERMIT OPENING5 THAT ALLOW <br />PA55AGE OF A 4 INCH DIAMETER 5PHERE WHERE 5UCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHE5 OF THE FINI5HED FLOOR PER F.B.C. <br />RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2. <br />WINDOW FALL PREVENTION DEVICE5 AND WINDOW GUARD5, WHERE <br />PROVIDED, 5HALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 <br />PER F.B.G. RESIDENTIAL 6th EDITION (2011)- SECTION R3122, <br />IN5ULATION NOTE5 <br />• CMU WALLS:----- R-FOIL 4.1 KNEE WALL5 THAT <br />BACK UP TO CEILING <br />• FRAME WALLS:-------- R-13 AREA ONLY:----------- R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URVEY NOTE <br />A FOUNDATION 5URVEY 5HALL BE PERFORMED AND A COPY OF THE <br />5URVEY 5HALL BE ON THE 51TE FOR THE BUILDING IN5PECTOR'5 U5E, <br />OR ALL PROPERTY MARKER5 5HALL BE EXP05ED AND A STRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />SETBACKS, <br />CELING AT ENTRY NOTE <br />ALL ENTRY CLG5, TO BE 15/32 058. CEMENTITOU5 FIN15H (UN.0) <br />GA5 APPLIANCE PROTECTION IN GARAGE NOTE <br />PROTECTION OF GAS APPLIANCES IN RE5IDENTIAL GARAGE5: <br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE <br />SLAB AND 3 FT. ABOVE FINISHED FLOOR, <br />GENERAL NOTES <br />• DUE TO VARIATION5 IN CITY REQUIREMENT5, 5UBDIV1510N <br />5PECIFICATION5, CON5TRUCTION TECHNIQUES, DIVERSITY IN <br />MATERIAL5, AND PLAN REV1510N5, ALL DIMEN51ON5 AND <br />ELEVATION5 MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD <br />CONDITION5 MAY VARY AND MU5T BE VERIFIED BEFORE <br />PROCEEDING WITH CONSTRUCTION. <br />• ELECTRICAL LOCATION5 5HM ON DRAWING5 MAY BE CHANGED <br />AT THE 50LE D15CRETION OF CALATLANTIC HOMES OR IT5 <br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODE5. CALATLANTIC <br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLET5 <br />AND / OR 5WITCHE5 5HOWN. <br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR 5LA8 EDGE. IT 15 THE <br />RE5PON51BILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMEN51ON5. <br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWING5 REFERENCING <br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CON5IDERED "NOMINAL DIMEN51ON5" <br />CHIMNEY HEIGHT REQUIREMENT5: <br />WHEN 5TANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT <br />EXTEND5 THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT 1510'-0" AWAY OR CLOSER. <br />TUE3 AND 5HOWER AREAS: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYP5UM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH 45TM 5288, 5325, OR C1118 <br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION5 5HALL BE USED A5 BACKER5 FOR WALL TILE IN TUB AND <br />5HOWER AREA5, AND WALL PANEL5 IN 5HOWER ARE45. <br />FLOOD ZONE REQUIREMENT5: <br />PLAN MEETS OR EXCEED5 FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. <br />DAMS BEWS <br />DESIGN GROUP <br />150 STATE STREET EAST <br />OLL76MAlt, FI.O1tIDA 34677 <br />813.92.5.1300 TEL <br />813.925.1800 FAX <br />WWW.DAVISBEWS.COM <br />TAMI'A • DEIVVER. <br />� EST. 1994 �- <br />t <br />0 <br />z " <br />N <br />(7�o <br />>�mC) <br />�) M � <br />oLn <br />Q fl. � <br />U 0- 00 <br />z�� <br />w Wo <br />J O <br />�o <br />oz <br />�s <br />w� <br />za <br />Z� <br />w¢wd <br />V) ro- <br />J <br />0 <br />H �aWZ <br />�aO�n <br />Lq <br />8 Ce K o <br />Ow�N <br />W COzO <br />oN <br />Q zz <br />r8 <br />�z <br />zw <br />z a <br />0 �� <br />Ob ;::; Q Q <br />p--1 <br />D ce �- <br />Oz <br />�w <br />w 0 <br />LJ.J <br />oc z Q oN w <br />z ... <br />Lu <br />z U z z 0 <br />0_U <br />u.i z <br />O '-' <br />z Q Lu 0 <br />m z <br />0 g <br />r, a w 00 <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />iso <br />SHEET NO. <br />DTI <br />