Laserfiche WebLink
TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />OI O <br />FRAMED WALL WITH OSB SUBSTRATE <br />I " O <br />ATTACH AT TOP ONLY <br />\ <br />\ <br />STEP 3.2 <br />TO ALLOW SHINGLING <br />MINIMUM OF 6" <br />J <br />OF WRB. <br />SELF -ADHERED / <br />I n n <br />\ <br />\ <br />\ <br />\ <br />\ <br />SELF-SEALING <br />WIE <br />V FRAMED WALL WITH OSB SUBSTRAT <br />O <br />\ <br />STEP 1 <br />\ <br />STEP 2 <br />\ <br />STEP 3 <br />\ <br />\ <br />\ <br />MEMBRANE <br />n <br />� <br />� <br />� <br />\ <br />\ <br />\ <br />\ <br />O I O I a <br />18" X 24" SELF- <br />FRAMER <br />FRAMER <br />STEP 3.1 <br />INBOARD SUB - FASCIA <br />FLASHING) <br />Installed by Housewrap <br />SEALING <br />CONSTRUCTS <br />CONSTRUCTS <br />HELD BACK 1 - INCH <br />MEMBRANE <br />ROOF <br />ROOF <br />FLASHING, (aka: <br />ROOF <br />(U1 <br />Target Flashing) <br />RAFTER TAIL <br />Flashing tape is to be <br />Installed by framer <br />installed behind the SAM <br />O O <br />I <br />target flashing <br />CMU WALL <br />EXSTEND PAST <br />CMU WALL <br />' <br />WOOD/CMU <br />iI <br />) �' <br />TRANSITION <br />TAMPA VER 8 <br />\ <br />TAMPA VER 8 <br />\ <br />TAMPA VER 8 <br />\ ` <br />TAMPA VER 8 <br />` <br />TAMPA VER 8 <br />TAMPA VER 8 <br />\ <br />MID WALL WEEP SCREED <br />\ <br />\ <br />\ <br />\ <br />` <br />CONTROL JOI NI \ <br />\ <br />\ 6 - INCH O.0 <br />\ <br />` <br />\ <br />��c� <br />STEP 6.1 & 7 <br />\ <br />STEP 7 <br />\ <br />\ <br />\ • � <br />\` � � <br />STEP 8 <br />�'�. �\ <br />STEP 9 <br />\ <br />\ <br />rO\�• \ <br />CONTINUOUS L <br />��� <br />�\ \ <br />�'L <br />\ <br />\ <br />4 - INCH O.C. \ <br />METAL FLASHING <br />` <br />\ \ <br />Florida applications: <br />`O ` <br />cF <br />STUCCO <br />\ <br />\ <br />\ <br />AND KICK -OUT <br />` <br />\ <br />Ensure flashing is set <br />ROOF SHINGLES <br />y, <br />ACCESSORIES, <br />\ <br />STEP 4 & 5 <br />\ <br />STEP 6 <br />• \ <br />FLASHING TO <br />` <br />• ` \ <br />flush to the wall and <br />WEEP SCREED & <br />\ <br />METAL ROOF DRIP CAP <br />METAL L FLASHIN \ <br />EXTEND A <br />` \ \ <br />over the underlayment. <br />5/8" ° <br />MID WALL <br />UNDERLAYMENT \ <br />UNDERLAYMENT <br />/ EDGE FLASHING <br />DRIP CAP / EDGE <br />\ 3' I <br />MINIMUM OF <br />`�, ` \ <br />Seal these areas with <br />�, ° <br />tea, <br />CONTROL JOINT, <br />& TIN SHINGLE <br />FLASHING <br />• <br />2-INCHES FROM <br />` <br />compatible flashing <br />APPROVED <br />mm° ° <br />cut and layer the <br />• <br />• I <br />THE WALL <br />, - <br />cement over the entire <br />SEALANT <br />AN, <br />"target" SSM/SAM <br />1-1/4" ROOFING <br />edge of the horizontal <br />2�, o °m <br />��� <br />and tin shingle <br />• <br />• <br />• <br />flange including nail <br />over the stucco <br />RECOMMENDED BUT <br />NAIL 6" O.C. ON17 <br />penetrations. <br />accessory <br />NOT REQUIRED: <br />• <br />• <br />THE TOP AND 4" <br />• <br />TIN SHINGLE <br />O.C. AT THE <br />ENSURE SSM IS <br />MIN OF 12" X 18", <br />• <br />• <br />BOTTOM OF THE <br />•L L <br />DAY -LIGHTED <br />Installed by Roofer. <br />METAL L-FLASHING <br />AFTER ACCESSORIES <br />A tin shingle (which <br />ARE INSTALLED <br />protects self - sealing <br />V1 <br />membrane from <br />cladder's knife). <br />` <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />TAMPA VER 8 <br />WOOD FRAMED WALL TO CMU WALL TRANSITION <br />STEP 10 <br />HOUSE <br />STEP 11 <br />OSB SUBSTRATE #6, 7/8" STUCCO <br />WRAP <br />REVIEW STEPS i - 10 <br />CORNER BEAD <br />STEP 12 <br />STEP 13 <br /># LATH <br />` � <br />HOUSE -WRAP <br />� <br />� <br />� <br />ACCESSORY <br />PAPER BACKED <br />STUCCO <br />4, 2ndE <br /># 4 2nd LAYER OF WEATHER <br />ROOF <br />ENSURE HOUSE -WRAP <br />WEEP <br />UNDERLAYMENT <br />�� <br />.. <br />DIAMOND MESH <br />( <br />2X SILL PLATE #3S 1stALAYER OF WRBWRB) <br />IS LAPPED ON TOP OF <br />SCRE <br />ROLLED A MIN OF <br />` <br />:: <br />SELF -FURRING <br />- - - <br />-- - #1, 9" SELF - <br />ACCESSORIES & <br />3-INCHES UNDER L <br />` <br />LATH <br />ADHERING <br />SHINGLE SELF <br />\ <br />FLASHING <br />\ <br />: ;; <br />�� MID WALL <br />MEMBRANE <br />ADHERING MEMBRANE <br />METAL L <br />i � <br />KICK -OUT <br />i <br />, <br />� <br />(SAM/SSM) CONTROL JOIN <br />SO HOUSE -WRAP IS <br />FLASHING <br />�L <br />� <br />FLASHING <br />;� <br />First apply <br />I <br />LAYERED BELOW THE <br />TARGET FLASHING AT <br />I <br />I <br />APPROVED <br />:: <br />v Q <br />approved primer <br />I <br />. THE BOTTOM <br />2, <br />� <br />SEALANT <br />I <br />I <br />; • <br />• <br />/adhesive <br />- -_- <br />spray <br />I <br />18" X 24" SELF- <br />SEALING <br />� <br />:: <br />� :: <br />■ .. <br />2'b <br />Terminate SAM / SSM on top of � F <br />I <br />MEMBRANE <br />• <br />CMU and above the perforated flange #2, MID WALL <br />5/8 <br />Q I <br />FLASHING <br />I <br />(M STYLE) <br />�Q <br />(SSM/SAM), Installed <br />CONTROL <br />ENSURE SSM/SAM <br />F� <br />I <br />by Framer <br />;� <br />CMU JOINT <br />Note: No Target Flashing Shown <br />IS DAY -LIGHTED <br />TIN SHINGLE <br />I <br />: ;; <br />#6, 5/8" STUCCO � ��` m ° <br />.! <br />AFTER HOUSE- <br />,•1P <br />J <br />/ <br />UNDER HOUSE -WRAP, <br />J <br />�� �� <br />Fo °� <br />WRAP IS <br />I <br />Installed by Roofer <br />INSTALLED <br />�FP <br />Sv <br />CONTROL JOINT <br />�• <br />DAY -LIGHTED SSM SAM <br />FLASHING & WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />MECHANICALLY FASTEN AS <br />NECESSARY IN CORNERS THROUGH <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />SELF -ADHERED FLASHING <br />FLASHING REQUIREMENTS <br />SELF -ADHERED FLASHING <br />TEMPORARILY SECURE <br />BARRIER <br />WEATHER <br />DOOR ROUGH OPENING <br />SLOPE <br />PRODUCTS DETAILS <br />R609.1 General. This section prescribes performance and construction requirements for exterior <br />RESISITIVE <br />BARRIER <br />WOOD FRAME CONSTR. <br />0.3 in: 12.0 in <br />30.5 <br />windows and doors installed in walls. Windows and doors shall be installed and flashed in accordance <br />with the fenestration manufacturer's written instructions. Window and door openings shall be flashed <br />(0.6 cm : cm) <br />TAPE <br />EXTERIOR <br />SELF -ADHERED FLASHIN <br />3/4"-1" BEAD OF CONSTR. <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />in accordance with Section R703.4. Written installation instructions shall be provided by the <br />3 <br />SHEATHING <br />BY LAPPING DOWN <br />OVER RIM JOISTAND U <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />SELF -ADHERED FLASHING <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />fenestration manufacturer for each window or door. <br />(ASSEMBLED <br />WALL BY 6 IN. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />EXTERIOR <br />Detail Instructions <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, <br />p <br />WINDOW) <br />Q : <br />OR EQUAL WEATHER <br />ATHER PROOF CA <br />CEMT. FIN. <br />complying with ASTM D226 for Type 1 felt or other approved water -resistive barrier shall be applied <br />2 <br />J <br />WEATHER <br />BUILDING PAPER <br />fer to the number marked as # in each detail that corresponds to the Re <br />over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the <br />pp y <br />O <br />SELF -ADHERED FLASHING <br />numbered items in the list of instructions below: <br />upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall <br />2 <br />RESISITIVE <br />BARRIER <br />WIRE LATH <br />be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to <br />SEAL TOPS OF JOIST <br />UNDER DECKING <br />!- <br />1. Install self -adhered flashing in order as shown b numbers <br />9 Y <br />the to of walls and terminated at penetrations and building appendages in a manner to meet <br />p p g <br />(SEE DETAIL WP07) <br />SUBFLOOR <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />the requirements of the exterior wall envelope as described in Section R703.1. The water -resistive <br />SELF -ADHERED FLASHING <br />3. Self -adhered flashing can be substituted for building paper <br />barrier is not required for detached accessory buildings. <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />4. Split the release paper using the ripcord (Split release on demand, embedded in <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner <br />1. Cut, fold up & temporarily secure weather resistive <br />RIM JOIST <br />the adhesive layer) - for ease of installation and to minimize scoring cuts <br />to prevent entry of water into the wall cavity or penetration of water to the building structural framing <br />barrier above header to allow for flashing installation <br />5. Remove all release paper per standard installation instructions and adhere to <br />components. Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />1 <br />1 <br />substrate using a square piece of flashing material (6" X 6" Minimum) <br />fenestration products shall be sealed at the juncture with the building wall with a sealant complying <br />with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />6. Fold as shown by arrows <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />2 <br />O <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight <br />contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the type of <br />sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The <br />to corner <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion resistant flashings <br />8. Mechanically fasten as necessary <br />shall be installed at the following locations: <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />WPM <br />FLASHING <br />�A/PO� <br />V V <br />SELF -ADHERED FLASHING <br />, /t /P03 <br />VV <br />1. 1.Exterior window and door openings. Flashing at exterior window and door openings shall <br />EXTERIOR <br />EXTERIOR DOOR <br />WITH DECK - SECTION <br />A <br />CEMT. FINISH <br />SILO POTSHELF/ CHIMNEY <br />SHOULDER <br />extend to the surface of the exterior wall finish or to the water -resistive barrier complying <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall comply <br />EXTERIOR SHEATHING-- <br />RUBBERIZED <br />RUBBERIZED ASPHALT <br />with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with <br />ASPHALT <br />ADHESIVE <br />one or more of the following: <br />� <br />ADHESIVE <br />SELF -ADHERED FLASHING <br />SHEATHING <br />1. 1.1.The fenestration manufacturer's installation and flashing instructions, or for applications not <br />REFER TO TECHNICA <br />' <br />1 <br />addressed in the fenestration manufacturer's instructions, in accordance with the flashing <br />LETTER ON CHEMICAL <br />0' <br />3% TO 5% SLOPE <br />manufacturer's instructions. Where flashing instructions or details are not provided, pan flashing shall <br />COMPATIBILITY <br />SCORED <br />TOWARDS SHOWER SIDE <br />be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in <br />SELF -ADHERED FLASHI <br />.. <br />,. <br />RELEASE PAPER <br />such a manner as to direct water to the surface of the exterior wall finish or to the water resistive <br />IBEF_OgE FOLDING, S <br />LE <br />E <br />SELF -ADHERED FLASHING <br />PATCH <br />barrier for subsequent drainage. Openings using pan flashing shall incorporate flashing or protection <br />at the head and sides. <br />SNE AS SHOW <br />MECHANICALLY FASTEN AS <br />2. 1.2.In accordance with the flashing design or method of a registered design professional. <br />2 s <br />NECESSARY IN CORNERS THROUGH <br />SHOWER <br />3. 1.3.In accordance with other approved methods. <br />SELF -ADHERED FLASHING <br />O Q :::..:: <br />SIDE <br />4. 1.4.In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA <br />SELF -ADHERED FLASHIN <br />2 <br />300 or FMA/AAMA/WDMA 400. <br />2. 2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />z <br />v <br />5 <br />1 SELF -ADHERED FLASHING 1 <br />projecting lips on both sides under stucco copings. <br />SELF -ADHERED FLASHING <br />3. 3.Under and at the ends of masonry, wood or metal copings and sills. <br />NAILING FLANGE <br />1 <br />4 <br />2 <br />NEEDED RIPPED AS <br />N <br />4. 4.Continuously above all projecting wood trim. <br />2 <br />6 <br />3" MIN <br />4 <br />1/2" OSB FLITCH <br />5. 5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />DO NOT FLASH OVER <br />8 <br />7 <br />5 <br />PLAN <br />construction. <br />BOTTOM NAILING <br />FLANGE <br />6. 6.At wall and roof intersections. <br />7. 7.At built-in gutters. <br />SELF -ADHERED FLASHING <br />WP04 <br />SELF <br />-ADHERED FLASHING <br />W P06 <br />SELF -ADHERED FLASHING <br />� A /P08 <br />V 1/ C� <br />SHOWER CURB DETAIL <br />\ A /P iTHESE <br />V V 1 <br />DETAILS ARE GENERIC AND MEANT TO SHOW <br />HALF ROUND WINDOW <br />INSIDE CORNER <br />OUTSIDE CORNER <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />BEWS <br />DESIGN G11tOVP <br />1S0 STATE STREET EAST <br />Oi.D6MAR, FLOIiIDA 39677 <br />813.925.1300 TEL <br />813.925.1800 FAX <br />W W W.DAVLSBEWS.COM <br />TAMPA • DEIVVER. <br />��a FST. 1994 ��-�- <br />I J1 L <br />O <br />Z � <br />0 N n <br />>Z - M O <br />o In <br />Q L_ LL <br />LL <br />ZQ V fl. <br />Z <br />W WO <br />J O <br />�O <br />d- <br />J <br />oz <br />o <br />�o <br />za <br />zZ <br />f <br />F- <br />w z a. <br />,^ ooWoo <br />�1�faZz <br />¢0�-� <br />LL <br />w H N <br />W �z0 <br />oN <br />Q zz <br />7 W <br />Z Z gb <br />0 <br />o b Q 4 <br />W <br />U <br />�LU <br />z Q N W <br />Q <br />Z U Z Z0 <br />� 0U <br />Lu Z �- <br />f--i <br />Z Q i� <br />co Z W <br />o 0- w kD m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />100 <br />SHEET NO. <br />DAVIS <br />