OPTIONAL OVERHEAD SERVICE SAME AS <br />UNDERGROUND 150 OR 200 AMP SERVICE <br />REFER TO FLOOR PLAN FOR <br />NOTED AMPS, REQUIRED <br />UNDERGROUND SERVICE <br />BY POWER COMPANY <br />14 GROUNDING WIRE WITH CODE <br />APPROVED CLAMP PER 250.50 <br />AND 250.52 OF THE 2014 NEC. <br />150 = 01 COPPER OR 2/0 ALUMINUM <br />200 = 2/0 COPPER OR 4/0 ALUMINUM IN 2" CONDUIT, <br />12 COPPER TO APPLIANCES AND GFI <br />014 COPPER TO LIGHTS AND OUTLETS <br />10 COPPER TO WATER HEATER <br />18 COPPER TO RANGE <br />% COPPER TO HVAC <br />INTERSYSTEM BONDING TERMINATION PER NEC 08, 250,54 <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS <br />OF THE NFPA 10-08, LOCAL CODES AND LOCAL POWER/UTILITY COMPANY <br />5TAIR NOTE5 <br />RAILING <br />BALU5TER5 SHALL BE SPACED SO THAT A 4" 5PHERE CANNOT PA55 THROUGH. <br />HANDRAILS <br />HANDRAILS FOR 5TAIRWAY5 SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP R15ER OF <br />THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST R15ER HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL PO5T5 OR <br />SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LE55 THAN 1-1/2 INCH BETWEEN THE WALL AND HANDRAILS. <br />CONTINUOUS GRASPABLE HANDRAIL MUST MEET TYPE ONE OR TYPE TWO CRITERIA <br />UNDER-5TAIR PROTECTION <br />ENCL05ED ACCE551BLE SPACE UNDER 5TAIR5 SHALL HAVE WALLS, UNDER-5TAIR 5URFACE AND ANY 59FIT PROTECTED ON THE <br />ENCLOSED 51DE W/ 1/2 INCH GYPSUM BOARD PER F.B.C. RESIDENTIAL 6th EDITION (2011) - R302.1 AND R302.11 <br />5TAIRWALL FRAME NOTE <br />ALL STAIRWELL SURROUNDING WALLS AND KNEE WALLS ARE TO BE FRAMED AT 16" O.C. TO PROTECT FROM FALLING HAZARD <br />OCCUPANCY AND CON5TRUCTION TYPE: <br />TH15 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-B CLA551FICATION. <br />CEILING CONSTRUCTION: <br />I. THE GARAGE 5HALL BE SEPARATED FROM THE RESIDENCE AND IT5 ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED <br />TO THE GARAGE 51DE. GARAGES BENEATH HABITABLE ROOMS 5HALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN <br />5/8 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION 15 A FLOOR -CEILING A55EMBLY, THE STRUCTURE <br />5UPPORTING THE SEPARATION 514ALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT. <br />DWELLING / GARAGE OPENING5: <br />I. THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 1 3/8" IN THICKNE55, <br />SOLID CORE (S.CJ OR HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1 3/5" THICK, OR 20 MINUTE FIRE RATED DOORS, <br />2. ALL DOORS FROM GARAGE ADJACENT TO LIVING 5PAGE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTES. <br />EGRE55: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCESS TO EXTERIOR THROUGH A DOOR. THE <br />WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. <br />WINDOW IN5TALLATION: <br />WINDOW5 SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION IN5TRUCTION5. WRITTEN <br />INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW, <br />TERMITE PROTECTION: <br />I. PENETRATION. PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF GELLUL05E <br />CONTAINING MATERIALS. IF 501L TREATMENT IS U5ED FOR 5U5TERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL <br />THICKNE55 OF 0210 INCH, AND BE SEALED WITHIN THE SLAB USING A NON-CORRO51VE CLAMPING DEVICE TO ELIMINATE THE ANNULAR 5PAGE <br />BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDE5 SHALL BE APPLIED INSIDE THE SLEEVE. <br />2. PROTECTION AGAINST DECAY AND TERMITE5. - CONDEN5ATE LINES, IRRIGATION / 5PRINKLER 5Y5TEM R15ER5 FOR SPRAY HEADS, AND ROOF <br />DOWN5POUT5 SHALL DISCHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL <br />EXTEN51ON5, OR 5PLA5H BLOCKS, GUTTER5 WITH DOWN5POUT5 ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INGHE5 (152 mm) <br />HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. <br />TOP RAILING <br />NOTE: 5UBFLOOR ADHESIVE 15 U5ED IN ADDITION <br />BALU5TER5 TO NAILS ON WOOD COMPONENTS, <br />MAX 5PACING 4" <br />1 X 8 PAINTED IUD. CAP STRINGER 15 LAMINATED TO A THICKNE55 EQUIVALENT TO <br />OGEE STOP THE 51ZE OF A 2 X 12 5.Y.P, AND IS NAILED TO EACH <br />TREAD W/ 16d NAILS FROM THIRD LAMINATE TO TREAD - <br />OPT. 2 X 2 BLOCKING NAILED <br />TO TREAD AND RISER <br />3-2 X 12 STRINGER 2 X BLOCKING NAILED TO STRINGER, <br />3/4" R15ER5 R15ER, AND TREAD, <br />2 X TREADS± RIP FROM 2x12 I X 5PRUCE 13 OR 3/4" CDX. <br />TO SIZE NOTED ON PLAN PLYWD. R15ER. <br />2 X SOUTHERN YELLOW PINE <br />(ACTUAL THICKNE55 151 1/2") TREAD, <br />TYP. OPT. RAILING ELEVATION <br />SCALE: 1/2" = 1'-0" <br />NEWEL P05T <br />TOP RAILING <br />BALUSTER 4" O.C. <br />SHOE RAIL (REMOVE <br />W/ METAL 5PINDLE5) <br />I X 8 PAINTED WD. CAP <br />OGEE STOP <br />r QUN LINt _ <br />OPTIONAL <br />&MUNQ DETAIL <br />SCALE. 1 I 0 <br />CLOSED RISER DETAIL <br />SCALE: 1/2" - 1'-0" <br />CARPI <br />CARPI <br />TREAC <br />R15ER <br />2X4WALL <br />1/2" GYP BD. <br />3/4" 5KIRT BD. <br />2 X 4 5PACER <br />2X12 <br />STRINGER <br />TYPICAL STAIR <br />FRAMING DETAIL <br />B 5CALE: 3/4" - I'-0" <br />GENERAL CONSTRUCTION NOTES <br />CHAPTERS AND 5ECTION5 REFER TO F.B.G. RESIDENTIAL 6th EDITION (2011) <br />MECHANICAL AND HVAC <br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPAGITIE5 SHALL BE FURNISHED BY THE GENERAL CONTRACTOR A5 AN ATTACHMENT TO <br />TH15 PLAN 5ET AT THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANGE5 SHALL BE ACCE5515LE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT <br />CONSTRUCTION, OTHER APPLIANGE5, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, <br />REPAIRED, OR REPLACED. A LEVEL WORKING 5PAGE AT LEAST 30 INCHE5 (162 mm) DEEP AND 30 INCHE5 (162 mm) WIDE SHALL BE PROVIDED IN <br />FRONT OF THE CONTROL 51DE TO 5ERVIGE AN APPLIANCE. <br />3. DUGT5 IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE <br />CONSTRUCTED OF A MIN. *26 GAUGE (0.48 mm) 5HEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />4. FOUNDATION5 AND 5UPPORT5 FOR OUTDOOR MECHANICAL 5Y5TEM5 SHALL BE RA15ED AT LEAST 3 INCHE5 (16 mm) ABOVE THE FINISHED <br />GRADE AND SHALL AL50 CONFORM TO THE MANUFACTURER'S INSTALLATION IN5TRUGTION5. <br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANGE5 SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO <br />ANY BUILDING COMPONENT WILL OCCUR A5 A RESULT OF STOPPAGE IN THE GONDEN5ATE DRAIN PIPING 5Y5TEM. THESE PANS SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF 5ECTION5 M14113, <br />EXHAU5T FAN5 AND VENTING: <br />(.OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAU5T 5Y5TEM SHALL BE D15CHARGED TO THE OUTDOORS, AIR SHALL <br />NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. <br />2. EXHAU5T AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND <br />SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, <br />CRAWL SPACE, OR OTHER AREAS IN51DE THE BUILDING. <br />3. DUCT LENGTH, THE MAXIMUM LENGTH OF A CLOTHE5 DRYER EXHAU5T DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE <br />WALL OR ROOF TERMINATION, THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0.19 RAD) BEND <br />AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.(o RAD) BEND. THE MAXIMUM LENGTH OF THE EXHAU5T DUCT DOES NOT INCLUDE THE TRANSITION <br />DUCT. <br />EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF <br />THE EXHAU5T DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE 5005TER FAN MANUFACTURER'S <br />INSTALLATION IN5TRUCTION5. WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND NOT READILY ACCE5515LE FROM THE ROOM IN WHICH <br />THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAU5T DUCT ENTERS THE WALL. THE <br />LABEL SHALL BEAR THE WORDS "TH15 DRYER EXHAU5T 5Y5TEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN." <br />4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAU5T LOGATION5 IN ACCORDANCE WITH <br />AMCA STANDARD 550 IN FBC. <br />ROUGH -IN IN5PECTION REQUE5T NOTE <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH-IN5 MUST BE <br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE <br />FRAMING INSPECTION, <br />WINDOW FALL PROTECTION <br />IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 <br />LOCATED MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR <br />SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE <br />WINDOW SHALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED <br />FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE <br />5ECTION5 OF WINDOW5 5HALL NOT PERMIT OPENINGS THAT ALLOW <br />PA55AGE OF A 4 INGH DIAMETER SPHERE WHERE SUCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHE5 OF THE FIN15HED FLOOR PER F.B.C. <br />RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2, <br />WINDOW FALL PREVENTION DEVICE5 AND WINDOW GUARDS, WHERE <br />PROVIDED, SHALL COMPLY WITH THE REQUIREMENTS OF A5TM F 2090 <br />PER F.B.C. RESIDENTIAL 6th EDITION (2011) - 5ECTION R312.2. <br />IN5ULATION NOTE5 <br />• CMU WALLS:----- R-FOIL 4.1 KNEE WALLS THAT <br />BACK UP TO CEILING <br />• FRAME WALLS:-------- R-13 AREA ONLY:----------- R-19 <br />• CEILING:------------- R-30 <br />ON51TE FOUNDATION 5URVEY NOTE <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A DOPY OF THE <br />5URVEY SHALL BE ON THE 51TE FOR THE BUILDING IN5PECTOR'5 U5E, <br />OR ALL PROPERTY MARKERS SHALL BE EXP05ED AND A STRING <br />5TRECHED FROM MARKER TO MARKER TO VERIFY REQUIRED <br />5ETBACK5. <br />CEOLNG AT ENTRY NOTE <br />ALL ENTRY CLG5. TO BE 15/32 058, GEMENTITOUS FIN15H (UN.0) <br />G45 APPLIANCE PROTECTION IN GARAGE NOTE <br />PROTECTION OF GA5 APPLIANGE5 IN RESIDENTIAL GARAGES: <br />MINIMUM 3" DIAMETER 5CH 40 5TEEL PIPE, 2 FT. BELOW CONCRETE <br />SLAB AND 3 FT, ABOVE FINISHED FLOOR <br />GENERAL NOTES <br />• DUE TO VARIATIONS IN CITY REQUIREMENTS, 5UBDIV15ION <br />5PECIFICATION5, CONSTRUCTION TECHNIQUES, DIVERSITY IN <br />MATERIALS, AND PLAN REVISIONS, ALL DIMEN51ON5 AND <br />ELEVATIONS MAY VARY PER INDIVIDUAL PLAN. ACTUAL FIELD <br />CONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE <br />PROCEEDING WITH CONSTRUCTION. <br />• ELECTRICAL LOCATIONS 514011N ON DRAWINGS MAY BE CHANGED <br />AT THE 50LE DISCRETION OF GALATLANTIG HOMES OR IT5 <br />LICENSED ELECTRICIAN IN ORDER TO COMPLY W/ NATIONAL AND <br />MUNICIPAL BUILDING AND ELECTRICAL CODE5, GALATLANTIG <br />HOMES WILL NOT GUARANTEE LOCATION OR QUANTITY OF OUTLETS <br />AND / OR 5WITCHE5 SHOWN. <br />• ALL PLUMBING DIMEN51ON5 ARE APPROXIMATE FROM THE CENTER <br />LINE OF THE FIXTURE TO THE EXTERIOR SLAB EDGE. IT 15 THE <br />RE5PON51BILITY OF THE PLUMBER TO VERIFY THE ACCURACY OF <br />ALL PLUMBING DIMEN51ON5. <br />NOTE: ANY DIMEN51ON5 AND/OR CALLOUT5 WITHIN TH15 5ET OF DRAWINGS REFERENCING <br />LUMBER 51ZE5 OR WALL THICKNE55E5 ARE TO BE CONSIDERED "NOMINAL DIMEN51ON5" <br />CHIMNEY HEIGHT REQUIREMENT5: <br />WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND Y-O" PAST THE HIGHER POINT WHERE IT <br />EXTENDS THROUGH THE ROOF AND MUST BE 2'-0" HIGHER THAN THE ROOF OR RIDGE THAT 15 10'.0" AWAY OR CL05ER <br />TUB AND 5HOWER AREAS: <br />CEMENT, FIBER -CEMENT, OR GLA55 MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM C1288, C1325, OR GI118 <br />AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED A5 BACKER5 FOR WALL TILE IN TUB AND <br />SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS, <br />FLOOD ZONE REQUIREMENT5: <br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION. <br />BEWS <br />DESIGN GROUP <br />150 STATE STREET EAST <br />O1.�sMAR, F1.oR1DA 3�6n <br />$13.925.1300 TEL <br />813. 925. 1800 FAX <br />W W W.DAVISBEWS.COM <br />TANIPI� • DEIVVF.Fi. <br />��-�a EST. 1994 F= �....- <br />0 <br />Z � <br />0�o <br />�z <br />:v,Mo <br />M <br />01 j M it <br />�aLn <br />L LL <br />CL <br />Q v <br />z�.. <br />w Wo <br />J 0 <br />0 <br />z <br />w� <br />za <br />a� <br />WQ�a. <br />� z 8 <br />U <br />�o LZLJ <br />U uj <br />W zo <br />zu <br />W <br />z z <br />03 <br />O Q J <br />0 < <br />ce 0w <br />u 0 <br />(J) w <br />7 oC <br />Q Z Q r4 W <br />z <br />LLJz V z zo <br />Q U <br />< O �� <br />z a w 0 <br />z > <br />_ _3 <br />0 0- w ko m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />100 <br />SHEET NO. <br />DAVISDT1 <br />