Laserfiche WebLink
30'-0" <br />11'-8" <br />7=11'-7" <br />& 6'-9" <br />3-1 2' <br />SH 25 <br />HD AT 6'-8" <br />EGRESS <br />5068 SGD O <br />H.B. <br />\ <br />°��° v, <br />2868 <br />r, <br />� J <br />\ N <br />\ N <br />OWNER'S SUITE <br />\ °p <br />15'-8" X 11'-11" <br />\ 0 <br />8'-0" CLG <br />ti <br />co <br />\ <br />12'-7 5/8" <br />6'-3" T-9 1/2" 6-0 5/8" <br />GREAT ROOM <br />14'-4" X 12'-6" <br />\ <br />VAULTED <br />2868 <br />2.5/12 VAULT. <br />_ _ _ � 2868 <br />CLG <br />12" DP O. BATH <br />(5) SH M 8'_0" CLG <br />W.I.0 TP <br />8'-0" CLG <br />36" x 60" Tbo <br />Co <br />SHOWER PAN <br />CD <br />I DRAIN <br />�' <br />o> <br />DINING <br />00 <br />m SHW HD <br />`" <br />M io <br />10'-0" X 12'-6" <br />co &VALVE <br />I <br />X Q <br />VAULTED <br />I <br />N <br />R&S N o <br />>0 .o. <br />u_ <br />oC <br />Co <br />8 � I 7'-3 1/2" 4'-2 5/8" <br />ii <br />o <br />CPT. <br />TILEm <br />I u_ v <br />M <br />N <br />-6I Co � <br />coLn BEDROOM #3 <br />KITCHEN j z <br />I N 11'-1" X 10'-1" <br />12'-6" X 13'-6" g <br />I N _ 8'-0" CLG <br />- <br />VAULTED O � c� iv <br />p ! <br />Z <br />C O N <br />T W <br />2.5/12 O `° U r` <br />VAULT. ---- <br />CLG x <br />Co <br />DW <br />2'-3 1/2" c° 11 '-6 1 /8" <br />b---- <br />---- <br />2668 <br />co <br />4,-6„ 2,-0„ <br />N <br />4'-5 1 /4" 7'-11 1/2" co <br />L T-9 3/8" '-3 1/2" 2668 10'-3 1 /8" <br />_ <br />co <br />00 <br />I <br />M <br />8'-0" CLG <br />�6�8 <br />REF04 <br />o <br />B9 DoROOM1#2 <br />N <br />5 SH <br />N <br />11 <br />8'-0" CLG <br />( ° TB TP <br />BATH I <br />c:0 <br />�51 2'-9 1 /2" T-2 3/4" 8'-0" CL#2G U I oo _ <br />06 CD bo <br />N , <br />Co - <br />r> � 4 I <br />0 <br />2.5/12 — <br />VAULT. p / INSULATED r <br />CLG = / o WALL <br />¢ r 20MIN. L---OD — <br />AHU PLATFORM M RATED <br />DOOR W/ <br />WEATHER 22-1/2" x 54" <br />LAUNDYATTIC ACCESS PROTECTIVE <br />~ FOYER 8'-0" CLG STRIP K BOLLARD <br />4'-4" X 12'-8" `'c96, co VAULTED ti <br />Ln SHELVES IN <br />LAUNDRY AT <br />60" A. F.F. <br />DRYER <br />o D W VENT <br />o - 3-1/2" BOXHAN <br />1 0 I T-8' 4" PADDED TWO CAR GARAGE <br />FRAME WALL 8'-0" CLG <br />SH 1/2 33 <br />! HD AT6'-8" _________ <br />I !LINE OF GARAGE IN <br />2'-0" 4'-0" ! OPEN POSITION <br />Cn I 4'-8" 61-0.1 ! ! <br />I I ! <br />PORCH ! ! <br />8'-0" CLG <br />I <br />o I I I I 16070 I <br />N , <br />2'-0" L 6'-8" 2'-0" L 1'-8" L 16'-0" L 1'-8" <br />10'-8" <br />30'-0" <br />FLOOR PLAN (ELEV B <br />�1 /4r, _ 1,_0/4r, _ 1,_�„ <br />(V <br />N <br />Cl) <br />GD <br />N O <br />W <br />U5Q0 <br />pW <br />o?(0 <br />N b V% <br />w� <br />MQw <br />ow <br />H.B. <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING SIZES <br />WITH THE MANUFACTURER'S SPECIFICATIONS. <br />INSTALL RND DRYWALL BEADS AT HORIZ & VERT <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS <br />NOTED. <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE <br />SMOOTH FINISH. <br />LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND <br />THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER <br />CODE. <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) <br />APPLIED TO THE GARAGE SIDE. <br />TOWEL BAR - (T.B.)' = 42" A.F.F. OR U.N.O. <br />TOWEL BAR ABV TUB DECK' = 36" ABV. TUB DECK <br />TOILET PAPER DISP. - (T.P.)' = 20" A.F.F. <br />ROD AND SHELF (SGL)- (R/S) = 60" A.F.F. <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. <br />CORNER SHELF = 56" A.F.F. <br />MEDICINE CABINET - (M.C.) = 75" TO TOP OF CABINET A.F.F. <br />'PROVIDE 2X BLOCKING IN WALL AT ALL LOCATIONS FOR <br />T.B. AND T.P. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 1X3 PT FURRING STRIP <br />3/4" INSUL BOARD 1/2" GYP <br />8" CMU <br />NON -BEARING 2X4 STUD W/ 1/2" GYP. <br />LINO <br />BEARING WALL 2X4 16" O.C. W/ 1/2" <br />GYP. UNO <br />p = FILLED CELL W/(1) #5 VERTICAL <br />® = FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB <br />= FILLED CELL W/(2) #5 VERTICAL <br />Q = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />SQUARE FOOTAGE: ELEV B <br />AREA <br />PROPOSED <br />FIRST FLOOR LIVING <br />1448 <br />TOTAL LIVING SQ FT 1448 <br />ENTRY <br />93 <br />GARAGE <br />387 <br />TOTAL SQ FT 1928 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2X4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2X6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />ocr 1 g zoz� <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Editio <br />by Debra Anne Klahr PX2300 <br />ALLOWABLE WIND SPEED DESIGN PRESSURE <br />(140 mph, enclosed, 3 sec. gust, 2.1/12 to 6.9.12 pitch, <br />Exposure C, Height=30 ft, Importance Factor-1.0, End <br />Zone= 4 ft) <br />As per Florida Building Code 7th edition (2020), <br />Residential Table R301.2 (4) (Wind Speed Conversions) <br />and ASCE 7-10 Methods <br />WALL <br />TRIBUTARY <br />AREA (ft)2 <br />INTERIOR <br />END <br />10 <br />39.4 <br />-42.1 <br />39.4 <br />-51.8 <br />20 <br />37.6 <br />40.5 <br />37.6 <br />-48.6 <br />50 <br />35.2 <br />-37.3 <br />35.2 <br />-43.7 <br />100 <br />33.4 <br />-35.6 <br />33.4 <br />-40.5 <br />GARAGED <br />30.0 <br />-33.9 <br />30.0 <br />-33.9 <br />N <br />N <br />LO <br />00 <br />L <br />a aio r� <br />¢ <br />z <br />r,o <br />W <br />p <br />w <br />ar <br />p <br />z <br />E <br />10M 0 <br />W. <br />C) N d <br />4_ <br />a " u a <br />E o <br />O 2 0 <br />O 8 m Q <br />^N` <br />Ci } <br />U W QN <br />Eri <br />W <br />UM00 <br />m <br />� a <br />a <br />W <br />LLJ <br />U W <br />�L vi W0H <br />�Q � "f99 z� <br />W°�_aoaW¢u.0oLL_jo <br />FQ— <br />U <br />P <br /><OJLL�oz�mo~ <br />U,v)ozOzOR00o0 <br />0 <br />aQ <br />� <br />O <br />(n <br />O <br />(LW W WPLU ZwX<ozJ��w <br />w0gP—¢ <br />Oa <br />p2UQ <br />z0 <br />0=Q QU_ <br />a9¢ <br />LL <br />!1 <br />0 <br />z 04 <br />OF- <br />> (/) q <br />fn CM O <br />J L0 <br />2��� <br />F— 0� cM <br />00 <br />ZF- <br />z <br />J O <br />d' <br />r� <br />o <br />o <br />o <br />0 <br />C1q <br />N <br />0 <br />N <br />ch <br />N <br />Co <br />rn <br />o <br />o <br />r- <br />o <br />' <br />' <br />z <br />N� <br />0 <br />. <br />L <br />> <br />C <br />N <br />cn <br />�^ <br />ZI- <br />W <br />v./ <br />¢ z <br />O <br />zw <br />M <br />-- <br />O <br />W <br />_ <br />woo <br />U <br />U U <br />Lo <br />F- <br />z01-- <br />pzj <br />pwo <br />Q <br />O <br />F- <br />a <br />Q <br />(� <br />Ip—I. <br />O <br />Z=O2 <br />. <br />04 <br />O <br />Q <br />z <br />gww <br />w <br />aZu_ <br />F- <br />C.)z <br />Q <br />0 <br />aL <br />W <br />1 <br />z <br />Z <br />W <br />O <br />co <br />N <br />O <br />LAST PLOT DATE <br />N <br />Z <br />.. <br />0 <br />FLOOR PLAN B <br />